The production of the strip sensors for the ATLAS Inner Tracker (ITk) will start in 2020. Nearly 22,000 large area sensors will be produced over a period of about five years by Hamamatsu Photonics ...K.K. (HPK). The institutes involved in the sensor development and production are committed to deliver and maintain the highest quality sensors for the experiment. A Quality Assurance (QA) strategy has been prepared to be carried out during the whole production period. Once the process has been characterized as providing the required pre-irradiation specifications and the proper radiation hardness, the onus is on the manufacturer to rigidly stick to that qualified process. Still, sample testing with specific device-element structures and irradiation of devices should be implemented by the ITk sensor collaboration.
A detailed irradiation and testing plan has been prepared by the ATLAS-ITk Collaboration, together with a newly designed test chip with specific structures to monitor different key technological and device parameters during the whole production. The tests and irradiations will be carried out on a sample basis. In order to have a practical methodology, samples from alternating batches will be sent for irradiations with protons, neutrons and gammas, and then tested in order to check that the characteristics remain within specifications. The detailed plan and the design and test methods for the structures in the test chip are presented here.
The objective of this paper was to process a polyamide 6.6 composite reinforced with long glass fibers (50wt.%) using a design of experiments to determine the processing conditions that ...simultaneously maximize the flexural strength and the surface quality of the molded composite. The analyzed factors were the barrel temperature profile, the injection speed and the screw speed. To maximize the flexural strength response variable and the surface quality, all studied parameters should be maintained at the higher levels. The analysis of microstructure of composites molded demonstrates that this combination of parameters promotes a greater orientation of the fibers in the outer layers, as well as prevents the migration of glass fiber to surface of the composite. This kind of microstructure is favorable to a better surface quality, and a greater flexural strength.
Display omitted
•Polyamide 6.6 thermoplastic composites with long glass fiber.•Design of experiments.•Evaluation of injection parameters in the flexural strength and surface quality of the artifacts.•Microstructural analysis.
MALTA2 is a depleted monolithic active pixel sensor (DMAPS) developed in the Tower 180 nm CMOS imaging process. Monolithic CMOS sensors offer advantages over current hybrid imaging sensors both in ...terms of increased tracking performance due to lower material budget but also in terms of ease of integration and construction costs due to the monolithic design. Current research and development efforts are aimed towards radiation-hard designs up to 100 Mrad in Total Ionizing Dose and 3×1015 1 MeV neq/cm2 in Non-Ionizing Energy Loss. One important property of a sensor’s radiation hardness is the depletion depth at which efficient charge collection is achieved via drift movement. Grazing angle test-beam data was taken during the 2023 SPS CERN test beam with the MALTA telescope and Edge Transient Current Technique studies were performed at DESY in order to develop a quantitative study of the depletion depth for un-irradiated, epitaxial MALTA2 samples. The study is planned to be extended for irradiated and Czochralski MALTA2 samples.
In this article, a low-power, radiation-hard front-end circuit for monolithic pixel sensors, designed to meet the requirements of low noise and low pixel-to-pixel variability, the key features to ...achieve high detection efficiencies, is presented. The sensor features a small collection electrode to achieve a small capacitance (<5 fF) and allows full CMOS in-pixel circuitry. The circuit is implemented in the 180-nm CMOS imaging technology from the TowerJazz foundry and integrated into the MALTA2 chip, which is part of a development that targets the specifications of the outer pixel layer of the ATLAS Inner Tracker upgrade at the LHC. One of the main challenges for monolithic sensors is a radiation hardness up to 10 15 1-MeV <inline-formula> <tex-math notation="LaTeX">\text {n}_{\text {eq}}/\text {cm}^{{2}} </tex-math></inline-formula> non-ionizing energy loss (NIEL) and 80 Mrad total ionizing dose (TID) required for this application. Tests up to <inline-formula> <tex-math notation="LaTeX">{3} \cdot {10}^{15} </tex-math></inline-formula> 1-MeV <inline-formula> <tex-math notation="LaTeX">\text {n}_{\text {eq}}/\text {cm}^{{2}} </tex-math></inline-formula> and 100 Mrad were performed on the MALTA2 sensor and front-end circuit, which still show good performance even after these levels of irradiation, promising for even more demanding applications such as the future experiments at the high-luminosity large hadron collider (HL-LHC).
Quad-module characterization with the MALTA monolithic pixel chip Dachs, F.; Zoubir, A.M.; Sharma, A. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
07/2024, Letnik:
1064
Journal Article
Recenzirano
The MALTA silicon pixel detector combines a depleted monolithic active pixel sensor (DMAPS) with a fully asynchronous front-end and readout. It features a high granularity pixel matrix with a 36.4 μm ...symmetric pixel pitch, low power consumption of <1 μW/pixel and low material budget with detector thicknesses as little as 50 μm. It achieves a radiation hardness to 100MRad TID and more than 1 × 10E15 1 MeV neq/cm2 with a time resolution of <2 ns (Pernegger et al., 2023).
In order to cover large sensitive areas efficiently with a minimum of power and data connections the development of modules, comprising of up to 4 MALTA detectors, is studied.
This contribution presents the beam test performance of parallel and serial powered MALTA 4-chip modules in an effort to characterize the sensor’s chip-to-chip data and power transmission and prepare the production of a first prototype of an ultra-light weight 4-chip module on a flexible circuit with next generation MALTA2 sensors.
The upgrade of the tracking detectors for the High Luminosity-LHC (HL-LHC) requires the development of novel radiation hard silicon sensors. The development of Depleted Monolithic Active Pixel ...Sensors targets the replacement of hybrid pixel detectors with radiation hard monolithic CMOS sensors. We designed, manufactured and tested radiation hard monolithic CMOS sensors in the TowerJazz 180 nm CMOS imaging technology with small electrodes pixel designs. These designs can achieve pixel pitches well below current hybrid pixel sensors (typically 50 × 50μm) for improved spatial resolution. Monolithic sensors in our design allow to reduce multiple scattering by thinning to a total silicon thickness of only 50μm. Furthermore monolithic CMOS sensors can substantially reduce detector costs. These well-known advantages of CMOS sensor for performance and costs can only be exploited in pp-collisions at HL-LHC if the DMAPS sensors are designed to be radiation hard, capable of high hit rates and have a fast signal response to satisfy the 25 ns bunch crossing structure of LHC. Through the development of the MALTA and Mini-MALTA sensors we show the necessary steps to achieve radiation hardness at 1015 neq/cm2 for DMAPS with small electrode designs. The sensors combine high granularity (pitch 36.4x36.4μm2), low detector capacitance (<5fF/pixel) of the charge collection electrode (3μm), low noise (ENC≈10 e−) and low power operation (1μW/pixel) with a fast signal response (25 ns bunch crossing). The sensors feature arrays of 512 × 512 (MALTA) and 16 × 64 (Mini-MALTA) pixels. To cope with high hit rates expected at HL-LHC (>200 MHz/cm2) we have implemented a novel high-speed asynchronous readout architecture. The paper summarises the optimisation of the pixel design to achieve radiation hard pixel designs with full efficiency after irradiation at >98% after 1015 neq/cm2).
MALTA monolithic pixel sensors in TowerJazz 180 nm technology Solans Sánchez, C.; Allport, P.; Asensi Tortajada, I. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2023, Letnik:
1057
Journal Article
Recenzirano
Odprti dostop
Depleted Monolithic Active Pixel Sensors are of highest interest at the HL-LHC and beyond for the replacement of the Pixel trackers in the outermost layers of experiments where the requirement on ...total area and cost effectiveness is much bigger. They aim to provide high granularity and low material budget over large surfaces with ease of integration. Our research focuses on MALTA, a radiation hard DMAPS with small collection electrode designed in TowerJazz 180 nm CMOS imaging technology and asynchronous read-out. Latest prototypes are radiation hard up to 2 × 1015 1 MeV neq/cm2 with a time resolution better than 2 ns.
► Polyamide 6.6 thermoplastic composite with long glass fiber. ► Processing by injection molding into a mold with flow restriction. ► Mathematical models to correlate the microstructure with the ...mechanical properties. ► Polymer composites as substitutes for metallic materials in automotive applications.
In this study, polyamide 6.6 with 40wt% of long glass fibers was processed by injection molding into a mold with the ability to simulate controlled flow restriction. The mechanical properties of the molded test specimens were evaluated to verify the application of the composites as substitutes for metallic materials in automotive applications and the influence of flow restriction on these properties. Mathematical models were used to calculate the tensile strength of the composites in order to validate the experimental results. It was found that the presence of the controlled flow restriction affects fiber length as well fiber orientation, both of which influence the final mechanical properties of the composite. Moreover, a high degree of anisotropy in the mechanical properties was observed.
MALTA is a depleted monolithic active pixel sensor (DMAPS) developed in the Tower Semiconductor 180-nm CMOS imaging process. Monolithic CMOS sensors offer advantages over current hybrid imaging ...sensors in terms of both increased tracking performance due to lower material budget and ease of integration and construction costs due to the integration of read-out and active sensor into one ASIC. Current research and development efforts are aimed toward radiation hard designs up to 100 Mrad in total ionizing dose (TID) and <inline-formula> <tex-math notation="LaTeX">1\,\, \times 10 ^{15}~1~\text {MeV}\text {n}_{\text {eq}}/\text {cm}^{2} </tex-math></inline-formula> in nonionizing energy loss (NIEL). The design of the MALTA sensors was specifically chosen to achieve radiation hardness up to these requirements and satisfy current and future collider constraints. The current MALTA pixel architecture uses small electrodes which provide less noise, higher signal voltage, and a better power-to-performance ratio. To counteract the loss of efficiency in pixel corners, modifications to the Tower process have been implemented. The MALTA sensors have been tested during the 2021 and 2022 SPS CERN Test Beam in the MALTA telescope. The telescope ran for the whole duration of the beam time and took data to characterize the novel MALTA2 variant and the performance of irradiated samples in terms of efficiency and cluster size. These campaigns show that MALTA is an interesting prospect for HL-LHC and beyond collider experiments, providing both very good tracking capabilities and radiation hardness in harsh radiation environments.