The American Thoracic Society committee on Proficiency Standards for Pulmonary Function Laboratories has recognized the need for a standardized reporting format for pulmonary function tests. Although ...prior documents have offered guidance on the reporting of test data, there is considerable variability in how these results are presented to end users, leading to potential confusion and miscommunication.
A project task force, consisting of the committee as a whole, was approved to develop a new Technical Standard on reporting pulmonary function test results. Three working groups addressed the presentation format, the reference data supporting interpretation of results, and a system for grading quality of test efforts. Each group reviewed relevant literature and wrote drafts that were merged into the final document.
This document presents a reporting format in test-specific units for spirometry, lung volumes, and diffusing capacity that can be assembled into a report appropriate for a laboratory's practice. Recommended reference sources are updated with data for spirometry and diffusing capacity published since prior documents. A grading system is presented to encourage uniformity in the important function of test quality assessment.
The committee believes that wide adoption of these formats and their underlying principles by equipment manufacturers and pulmonary function laboratories can improve the interpretation, communication, and understanding of test results.
The aim of the Task Force was to derive continuous prediction equations and their lower limits of normal for spirometric indices, which are applicable globally. Over 160,000 data points from 72 ...centres in 33 countries were shared with the European Respiratory Society Global Lung Function Initiative. Eliminating data that could not be used (mostly missing ethnic group, some outliers) left 97,759 records of healthy nonsmokers (55.3% females) aged 2.5-95 yrs. Lung function data were collated and prediction equations derived using the LMS method, which allows simultaneous modelling of the mean (mu), the coefficient of variation (sigma) and skewness (lambda) of a distribution family. After discarding 23,572 records, mostly because they could not be combined with other ethnic or geographic groups, reference equations were derived for healthy individuals aged 3-95 yrs for Caucasians (n=57,395), African-Americans (n=3,545), and North (n=4,992) and South East Asians (n=8,255). Forced expiratory value in 1 s (FEV(1)) and forced vital capacity (FVC) between ethnic groups differed proportionally from that in Caucasians, such that FEV(1)/FVC remained virtually independent of ethnic group. For individuals not represented by these four groups, or of mixed ethnic origins, a composite equation taken as the average of the above equations is provided to facilitate interpretation until a more appropriate solution is developed. Spirometric prediction equations for the 3-95-age range are now available that include appropriate age-dependent lower limits of normal. They can be applied globally to different ethnic groups. Additional data from the Indian subcontinent and Arabic, Polynesian and Latin American countries, as well as Africa will further improve these equations in the future.
Normal values for FEV
and FVC are currently calculated using cross-sectional reference equations that include terms for race/ethnicity, an approach that may reinforce disparities and is of unclear ...clinical benefit.
To determine whether race/ethnicity-based spirometry reference equations improve the prediction of incident chronic lower respiratory disease (CLRD) events and mortality compared with race/ethnicity-neutral equations.
The MESA Lung Study, a population-based, prospective cohort study of White, Black, Hispanic, and Asian adults, performed standardized spirometry from 2004 to 2006. Predicted values for spirometry were calculated using race/ethnicity-based equations following guidelines and, alternatively, race/ethnicity-neutral equations without terms for race/ethnicity. Participants were followed for events through 2019.
The mean age of 3,344 participants was 65 years, and self-reported race/ethnicity was 36% White, 25% Black, 23% Hispanic, and 17% Asian. There were 181 incident CLRD-related events and 547 deaths over a median of 11.6 years. There was no evidence that percentage predicted FEV
or FVC calculated using race/ethnicity-based equations improved the prediction of CLRD-related events compared with those calculated using race/ethnicity-neutral equations (difference in C statistics for FEV
, -0.005; 95% confidence interval CI, -0.013 to 0.003; difference in C statistic for FVC, -0.008; 95% CI, -0.016 to -0.0006). Findings were similar for mortality (difference in C statistics for FEV
, -0.002; 95% CI, -0.008 to 0.003; difference in C statistics for FVC, -0.004; 95% CI, -0.009 to 0.001).
There was no evidence that race/ethnicity-based spirometry reference equations improved the prediction of clinical events compared with race/ethnicity-neutral equations. The inclusion of race/ethnicity in spirometry reference equations should be reconsidered.
This document addresses aspects of the performance and interpretation of spirometry that are particularly important in the workplace, where inhalation exposures can affect lung function and cause or ...exacerbate lung diseases, such as asthma, chronic obstructive pulmonary disease, or fibrosis.
Issues that previous American Thoracic Society spirometry statements did not adequately address with respect to the workplace were identified for systematic review. Medline 1950-2012 and Embase 1980-2012 were searched for evidence related to the following: training for spirometry technicians; testing posture; appropriate reference values to use for Asians in North America; and interpretative strategies for analyzing longitudinal change in lung function. The evidence was reviewed and technical recommendations were developed.
Spirometry performed in the work setting should be part of a comprehensive workplace respiratory health program. Effective technician training and feedback can improve the quality of spirometry testing. Posture-related changes in FEV1 and FVC, although small, may impact interpretation, so testing posture should be kept consistent and documented on repeat testing. Until North American Asian-specific equations are developed, applying a correction factor of 0.88 to white reference values is considered reasonable when testing Asian American individuals in North America. Current spirometry should be compared with previous tests. Excessive loss in FEV1 over time should be evaluated using either a percentage decline (15% plus loss expected due to aging) or one of the other approaches discussed, taking into consideration testing variability, worker exposures, symptoms, and other clinical information.
Important aspects of workplace spirometry are discussed and recommendations are provided for the performance and interpretation of workplace spirometry.
After the pioneering investigations into graphene-based electronics at Georgia Tech, great strides have been made developing epitaxial graphene on silicon carbide (EG) as a new electronic material. ...EG has not only demonstrated its potential for large scale applications, it also has become an important material for fundamental two-dimensional electron gas physics. It was long known that graphene mono and multilayers grow on SiC crystals at high temperatures in ultrahigh vacuum. At these temperatures, silicon sublimes from the surface and the carbon rich surface layer transforms to graphene. However the quality of the graphene produced in ultrahigh vacuum is poor due to the high sublimation rates at relatively low temperatures. The Georgia Tech team developed growth methods involving encapsulating the SiC crystals in graphite enclosures, thereby sequestering the evaporated silicon and bringing growth process closer to equilibrium. In this confinement controlled sublimation (CCS) process, very high-quality graphene is grown on both polar faces of the SiC crystals. Since 2003, over 50 publications used CCS grown graphene, where it is known as the "furnace grown" graphene. Graphene multilayers grown on the carbon-terminated face of SiC, using the CCS method, were shown to consist of decoupled high mobility graphene layers. The CCS method is now applied on structured silicon carbide surfaces to produce high mobility nano-patterned graphene structures thereby demonstrating that EG is a viable contender for next-generation electronics. Here we present for the first time the CCS method that outperforms other epitaxial graphene production methods.
The 2005 American Thoracic Society (ATS)/European Respiratory Society (ERS) spirometry guidelines define valid tests as having three acceptable blows and a repeatable forced vital capacity (FVC) and ...forced expiratory volume in 1 s (FEV1). The aim of this study was to determine how reviewer and computer-determined ATS/ERS quality could affect population reference values for FVC and FEV1. Spirometry results from 7777 normal subjects aged 8-80 years (NHANES (National Health and Nutrition Examination Survey) III) were assigned quality grades A to F for FVC and FEV1 by a computer and one reviewer (reviewer 1). Results from a subgroup of 1466 Caucasian adults (aged 19-80 years ) were reviewed by two additional reviewers. Mean deviations from NHANES III predicted for FVC and FEV1 were examined by quality grade (A to F). Reviewer 1 rejected (D and F grade) 5.2% of the 7777 test sessions and the computer rejected ∼16%, primarily due to end-of-test (EOT) failures. Within the subgroup, the computer rejected 11.5% of the results and the three reviewers rejected 3.7-5.9%. Average FEV1 and FVC were minimally influenced by grades A to C allocated by reviewer 1. Quality assessment of individual blows including EOT assessments should primarily be used as an aid to good quality during testing rather than for subsequently disregarding data. Reconsideration of EOT criteria and its application, and improved grading standards and training in over-reading are required. Present EOT criteria results in the exclusion of too many subjects while having minimal impact on predicted values.
The American Thoracic Society recommends race-specific spirometric reference values from the National Health and Nutrition Survey (NHANES) III for clinical evaluation of pulmonary function in whites, ...African-Americans, and Mexican-Americans in the United States and a correction factor of 0.94 for Asian-Americans. We aimed to validate the NHANES III reference equations and the correction factor for Asian-Americans in an independent, multiethnic sample of US adults.
The Multi-Ethnic Study of Atherosclerosis (MESA) recruited self-identified non-Hispanic white, African-American, Hispanic, and Asian-American participants aged 45 to 84 years at six US sites. The MESA-Lung Study assessed prebronchodilator spirometry among 3,893 MESA participants who performed acceptable tests, of whom 1,068 were asymptomatic healthy nonsmokers who performed acceptable spirometry.
The 1,068 participants were mean age 65 +/- 10 years, 60% female, 25% white, 20% African-American, 23% Hispanic, and 32% Asian-American. Observed values of FEV(1), FEV(6), and FVC among whites, African-Americans, and Hispanics of Mexican origin in MESA-Lung were slightly lower than predicted values based on NHANES III. Observed values among Hispanics of non-Mexican origin were consistently lower. Agreement in classification of participants with airflow obstruction based on lower limit of normal criteria was good (overall kappa = 0.88). For Asian-Americans, a correction factor of 0.88 was more accurate than 0.94.
The NHANES III reference equations are valid for use among older adults who are white, African-American, or Hispanic of Mexican origin. Comparison of white and Asian-American participants suggests that a correction factor of 0.88, applied to the predicted and lower limits of normal values, is more appropriate than the currently recommended value of 0.94.
Graphene's extraordinary physical properties and its planar geometry make it an ideal candidate for a wide array of applications, many of which require controlled chemical modification and the ...spatial organization of molecules on its surface. In particular, the ability to functionalize and micropattern graphene with proteins is relevant to bioscience applications such as biomolecular sensors, single-cell sensors, and tissue engineering. We report a general strategy for the noncovalent chemical modification of epitaxial graphene for protein immobilization and micropatterning. We show that bifunctional molecule pyrenebutanoic acid-succinimidyl ester (PYR-NHS), composed of the hydrophobic pyrene and the reactive succinimide ester group, binds to graphene noncovalently but irreversibly. We investigate whether the chemical treatment perturbs the electronic band structure of graphene using X-ray photoemission (XPS) and Raman spectroscopy. Our results show that the sp(2) hybridization remains intact and that the π band maintains its characteristic Lorentzian shape in the Raman spectra. The modified graphene surfaces, which bind specifically to amines in proteins, are micropatterned with arrays of fluorescently labeled proteins that are relevant to glucose sensors (glucose oxidase) and cell sensor and tissue engineering applications (laminin).