Objectives This study sought to evaluate 4-year outcomes of percutaneous repair versus surgery for mitral regurgitation. Background Transcatheter therapies are being developed to treat valvular heart ...disease. In the EVEREST (Endovascular Valve Edge-to-Edge Repair Study) II trial, treatment of mitral valve regurgitation (MR) with a novel percutaneous device was compared with surgery and showed superior safety, but less reduction in MR at 1 year overall. We report the 4-year outcomes from the EVEREST II trial. Methods Patients with grade 3+ or 4+ MR were randomly assigned to percutaneous repair with the MitraClip (Abbott, Menlo Park, California) device or conventional mitral valve surgery in a 2:1 ratio (184:95). Patients prospectively consented to 5 years of follow-up. Results At 4 years, the rate of the composite endpoint of freedom from death, surgery, or 3+ or 4+ MR in the intention-to-treat population was 39.8% versus 53.4% in the percutaneous repair group and surgical groups, respectively (p = 0.070). Rates of death were 17.4% versus 17.8% (p = 0.914), and 3+ or 4+ MR was present in 21.7% versus 24.7% (p = 0.745) at 4 years of follow-up, respectively. Surgery for mitral valve dysfunction, however, occurred in 20.4% versus 2.2% (p < 0.001) at 1 year and 24.8% versus 5.5% (p < 0.001) at 4 years. Conclusions Patients treated with percutaneous repair of the mitral valve more commonly required surgery to treat residual MR; however, after the first year of follow-up, there were few surgeries required after either percutaneous or surgical treatment and no difference in the prevalence of moderate-severe and severe MR or mortality at 4 years. (Endovascular Valve Edge-to-Edge Repair Study EVEREST II; NCT00209274 )
Objectives The EVEREST II (Endovascular Valve Edge-to-Edge Repair) High Risk Study (HRS) assessed the safety and effectiveness of the MitraClip device (Abbott Vascular, Santa Clara, California) in ...patients with significant mitral regurgitation (MR) at high risk of surgical mortality rate. Background Patients with severe MR (3 to 4+) at high risk of surgery may benefit from percutaneous mitral leaflet repair, a potentially safer approach to reduce MR. Methods Patients with severe symptomatic MR and an estimated surgical mortality rate of ≥12% were enrolled. A comparator group of patients screened concurrently but not enrolled were identified retrospectively and consented to compare survival in patients treated by standard care. Results Seventy-eight patients underwent the MitraClip procedure. Their mean age was 77 years, >50% had previous cardiac surgery, and 46 had functional MR and 32 degenerative MR. MitraClip devices were successfully placed in 96% of patients. Protocol-predicted surgical mortality rate in the HRS and concurrent comparator group was 18.2% and 17.4%, respectively, and Society of Thoracic Surgeons calculator estimated mortality rate was 14.2% and 14.9%, respectively. The 30-day procedure-related mortality rate was 7.7% in the HRS and 8.3% in the comparator group (p = NS). The 12-month survival rate was 76% in the HRS and 55% in the concurrent comparator group (p = 0.047). In surviving patients with matched baseline and 12-month data, 78% had an MR grade of ≤2+. Left ventricular end-diastolic volume improved from 172 ml to 140 ml and end-systolic volume improved from 82 ml to 73 ml (both p = 0.001). New York Heart Association functional class improved from III/IV at baseline in 89% to class I/II in 74% (p < 0.0001). Quality of life was improved (Short Form-36 physical component score increased from 32.1 to 36.1 p = 0.014 and the mental component score from 45.5 to 48.7 p = 0.065) at 12 months. The annual rate of hospitalization for congestive heart failure in surviving patients with matched data decreased from 0.59 to 0.32 (p = 0.034). Conclusions The MitraClip device reduced MR in a majority of patients deemed at high risk of surgery, resulting in improvement in clinical symptoms and significant left ventricular reverse remodeling over 12 months. (Pivotal Study of a Percutaneous Mitral Valve Repair System EVEREST II; NCT00209274 )
Abstract Background Surgical mitral valve repair (SMVR) remains the gold standard for severe degenerative mitral regurgitation (DMR). However, the results with transcatheter mitral valve repair ...(TMVR) in prohibitive-risk DMR patients have not been previously reported. Objectives This study aimed to evaluate treatment of mitral regurgitation (MR) in patients with severe DMR at prohibitive surgical risk undergoing TMVR. Methods A prohibitive-risk DMR cohort was identified by a multidisciplinary heart team that retrospectively evaluated high-risk DMR patients enrolled in the EVEREST (Endovascular Valve Edge-to-Edge Repair Study) II studies. Results A total of 141 high-risk DMR patients were consecutively enrolled; 127 of these patients were retrospectively identified as meeting the definition of prohibitive risk and had 1-year follow-up (median: 1.47 years) available. Patients were elderly (mean age: 82.4 years), severely symptomatic (87% New York Heart Association class III/IV), and at prohibitive surgical risk (STS score: 13.2 ± 7.3%). TMVR (MitraClip) was successfully performed in 95.3%; hospital stay was 2.9 ± 3.1 days. Major adverse events at 30 days included death in 6.3%, myocardial infarction in 0.8%, and stroke in 2.4%. Through 1 year, there were a total of 30 deaths (23.6%), with no survival difference between patients discharged with MR ≤1+ or MR 2+. At 1 year, the majority of surviving patients (82.9%) remained MR ≤2+ at 1 year, and 86.9% were in New York Heart Association functional class I or II. Left ventricular end-diastolic volume decreased (from 125.1 ± 40.1 ml to 108.5 ± 37.9 ml; p < 0.0001 n = 69 survivors with paired data). SF-36 quality-of-life scores improved and hospitalizations for heart failure were reduced in patients whose MR was reduced. Conclusions TMVR in prohibitive surgical risk patients is associated with safety and good clinical outcomes, including decreases in rehospitalization, functional improvements, and favorable ventricular remodeling, at 1 year. (Real World Expanded Multi-center Study of the MitraClip System REALISM; NCT01931956 )
Percutaneous mitral repair is rapidly developing as an alternative to cardiac surgery in select patients. The Evalve percutaneous E2E system uses the MitraClip to replicate the surgical suture-based ...approach. This procedure requires real-time echocardiographic guidance in a unique and significant collaboration between echocardiographer and interventionalist. transesophageal echocardiography (TEE) is used as the primary imaging modality to guide this procedure and is essential to its success.
In EVEREST I, the US multicenter phase I safety and feasibility trial, 47 patients with 3 or 4+ mitral regurgitation (MR) were enrolled. The trial involved a standardized echocardiographic imaging protocol with a standardized anatomic-based vocabulary, predetermined standard TEE views, preprocedural strategy meetings, and display of echocardiographic aids to optimize communication and procedural efficiency during placement of the clip.
TEE guidance facilitated the creation of a double-orifice mitral valve in all 47 patients enrolled (100%), and 40 patients were discharged with 1 or more clips (85%). At discharge, successful placement of a clip and <or= 2+ MR was present in 34 patients (74%). The standardized approach contributed to a reduction in the time to perform the procedure over the course of the trial at both initial and new sites.
TEE is essential to the guidance of percutaneous MitraClip E2E repair. A streamlined approach to echocardiographic guidance, using predetermined standardized views, a common anatomic-based vocabulary, preprocedural strategy meetings, and a display of echocardiographic aids in the catheterization laboratory shortens the procedure time and allows for efficient percutaneous repair.
Abstract Background In patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR), studies have suggested that reduced left ventricular (LV) ejection fraction (LVEF) and ...low aortic valve gradient (AVG) are associated with worse long-term outcomes. Because these conditions commonly coexist, the extent to which they are independently associated with outcomes after TAVR is unknown. Objectives The purpose of this study was to evaluate the impact of LVEF and AVG on clinical outcomes after TAVR and to determine whether the effect of AVG on outcomes is modified by LVEF. Methods Using data from 11,292 patients who underwent TAVR as part of the Transcatheter Valve Therapies Registry, we examined rates of 1-year mortality and recurrent heart failure in patients with varying levels of LV dysfunction (LVEF <30% vs. 30% to 50% vs. >50%) and AVG (<40 mm Hg vs. ≥40 mm Hg). Multivariable models were used to estimate the independent effect of AVG and LVEF on outcomes. Results During the first year of follow-up after TAVR, patients with LV dysfunction and low AVG had higher rates of death and recurrent heart failure. After adjustment for other clinical factors, only low AVG was associated with higher mortality (hazard ratio: 1.21; 95% confidence interval: 1.11 to 1.32; p < 0.001) and higher rates of heart failure (hazard ratio: 1.52; 95% confidence interval: 1.36 to 1.69; p <0.001), whereas the effect of LVEF was no longer significant. There was no evidence of effect modification between AVG and LVEF with respect to either endpoint. Conclusions In this series of real-world patients undergoing TAVR, low AVG, but not LV dysfunction, was associated with higher rates of mortality and recurrent heart failure. Although these findings suggest that AVG should be considered when evaluating the risks and benefits of TAVR for individual patients, neither severe LV dysfunction nor low AVG alone or in combination provide sufficient prognostic discrimination to preclude treatment with TAVR.
The Acute Hemodynamic Effects of MitraClip Therapy Siegel, Robert J., MD; Biner, Simon, MD; Rafique, Asim M., MD ...
Journal of the American College of Cardiology,
04/2011, Letnik:
57, Številka:
16
Journal Article
Recenzirano
Odprti dostop
Objectives The objective of this study was to evaluate the acute hemodynamic consequences of mitral valve (MV) repair with the MitraClip device (Abbott Vascular, Menlo Park, California). Background ...Whether surgical correction of mitral regurgitation (MR) results in a low cardiac output (CO) state because of an acute increase in afterload remains controversial. The acute hemodynamic consequences of MR reduction with the MitraClip device have not been studied. Methods We evaluated 107 patients with cardiac catheterization before and immediately following percutaneous MV repair with the MitraClip device. In addition, pre- and post-procedural hemodynamic parameters were studied by transthoracic echocardiography. Results MitraClip treatment was attempted in 107 patients, and in 96 (90%) patients, a MitraClip was deployed. Successful MitraClip treatment resulted in: 1) an increase in CO from 5.0 ± 2.0 l/min to 5.7 ± 1.9 l/min (p = 0.003); 2) an increase in forward stroke volume (FSV) from 57 ± 17 ml to 65 ± 18 ml (p < 0.001); and 3) a decrease in systemic vascular resistance from 1,226 ± 481 dyn·s/cm5 to 1,004 ± 442 dyn·s/cm5 (p < 0.001). In addition, there was left ventricular (LV) unloading manifested by a decrease in LV end-diastolic pressure from 11.4 ± 9.0 mm Hg to 8.8 ± 5.8 mm Hg (p = 0.016) and a decrease in LV end-diastolic volume from 172 ± 37 ml to 158 ± 38 ml (p < 0.001). None of the patients developed acute post-procedural low CO state. Conclusions Successful MV repair with the MitraClip system results in an immediate and significant improvement in FSV, CO, and LV loading conditions. There was no evidence of a low CO state following MitraClip treatment for MR. These favorable hemodynamic effects with the MitraClip appear to reduce the risk of developing a low CO state, a complication occasionally observed after surgical MV repair for severe MR. (A Study of the Evalve Cardiovascular Valve Repair System Endovascular Valve Edge-to-Edge Repair Study EVEREST I; NCT00209339 and EVEREST II; NCT00209274 )
Abstract Objectives The purpose of this study was to determine the safety and effectiveness of the SAPIEN XT versus SAPIEN systems (Edwards Lifesciences, Irvine, California) in patients with ...symptomatic, severe aortic stenosis (AS) who were not candidates for surgery. Background Transcatheter aortic valve replacement (TAVR) has become the standard of care for inoperable patients with severe, symptomatic AS. In the PARTNER (Placement of Aortic Transcatheter Valves) IB trial, a reduction in all-cause mortality was observed in patients undergoing TAVR with the balloon-expandable SAPIEN transcatheter heart valve compared with standard therapy, but the SAPIEN valve was associated with adverse periprocedural complications, including vascular complications, major bleeding, and paravalvular regurgitation. The newer, low-profile SAPIEN XT system was developed to reduce these adverse events. Methods A total of 560 patients were enrolled at 28 sites in the United States from April 2011 to February 2012. Patients were randomized to receive the SAPIEN or SAPIEN XT systems. The primary endpoint was a nonhierarchical composite of all-cause mortality, major stroke, and rehospitalization at 1 year in the intention-to-treat population, assessed by noninferiority testing. Pre-specified secondary endpoints included cardiovascular death, New York Heart Association functional class, myocardial infarction, stroke, acute kidney injury, vascular complications, bleeding, 6-min walk distance, and valve performance (by echocardiography). Results Both overall and major vascular complications were higher at 30 days in patients undergoing TAVR with SAPIEN compared with SAPIEN XT (overall: 22.1% vs. 15.5%; p = 0.04; major: 15.2% vs. 9.5%; p = 0.04). Bleeding requiring blood transfusions was also more frequent with SAPIEN compared with SAPIEN XT (10.6% vs. 5.3%; p = 0.02). At 1-year follow-up, the nonhierarchical composite of all-cause mortality, major stroke, or rehospitalization was similar (37.7% SAPIEN vs. 37.2% SAPIEN XT; noninferiority p value <0.002); no differences in the other major pre-specified endpoints were found. Conclusions In inoperable patients with severe, symptomatic AS, the lower-profile SAPIEN XT is noninferior to SAPIEN with fewer vascular complications and a lesser need for blood transfusion. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves; NCT01314313 )
Summary Background Based on the early results of the Placement of Aortic Transcatheter Valves (PARTNER) trial, transcatheter aortic valve replacement (TAVR) is an accepted treatment for patients with ...severe aortic stenosis who are not suitable for surgery. However, little information is available about the late clinical outcomes in such patients. Methods We did this randomised controlled trial at 21 experienced valve centres in Canada, Germany, and the USA. We enrolled patients with severe symptomatic inoperable aortic stenosis and randomly assigned (1:1) them to transfemoral TAVR or to standard treatment, which often included balloon aortic valvuloplasty. Patients and their treating physicians were not masked to treatment allocation. The randomisation was done centrally, and sites learned of the assignment only after a patient had been screened, consented, and entered into the database. The primary outcome of the trial was all-cause mortality at 1 year in the intention-to-treat population, here we present the prespecified findings after 5 years. This study is registered with ClinicalTrials.gov , number NCT00530894. Findings We screened 3015 patients, of whom 358 were enrolled (mean age 83 years, Society of Thoracic Surgeons Predicted Risk of Mortality 11·7%, 54% female). 179 were assigned to TAVR treatment and 179 were assigned to standard treatment. 20 patients crossed over from the standard treatment group and ten withdrew from study, leaving only six patients at 5 years, of whom five had aortic valve replacement treatment outside of the study. The risk of all-cause mortality at 5 years was 71·8% in the TAVR group versus 93·6% in the standard treatment group (hazard ratio 0·50, 95% CI 0·39–0·65; p<0·0001). At 5 years, 42 (86%) of 49 survivors in the TAVR group had New York Heart Association class 1 or 2 symptoms compared with three (60%) of five in the standard treatment group. Echocardiography after TAVR showed durable haemodynamic benefit (aortic valve area 1·52 cm2 at 5 years, mean gradient 10·6 mm Hg at 5 years), with no evidence of structural valve deterioration. Interpretation TAVR is more beneficial than standard treatment for treatment of inoperable aortic stenosis. TAVR should be strongly considered for patients who are not surgical candidates for aortic valve replacement to improve their survival and functional status. Appropriate selection of patients will help to maximise the benefit of TAVR and reduce mortality from severe comorbidities. Funding Edwards Lifesciences.
The effect of aortic valve replacement on three-dimensional mitral annular geometry has not been well described. Emerging transcatheter approaches for aortic valve replacement employ fundamentally ...different mechanical techniques for achieving fixation and seal of the prosthetic valve than standard surgical aortic valve replacement. This study compares the immediate impact of transcatheter aortic valve replacement (TAVR) and standard surgical aortic valve replacement (AVR) on mitral annular anatomy.
Real-time three-dimensional echocardiography was performed in patients undergoing TAVR using the Edwards Sapien valve (n = 10 Edwards Lifesciences, Irvine, CA) or AVR (n = 10) for severe aortic stenosis. Mitral annular geometric indexes were measured using Tomtec EchoView (Tomtec Imaging Systems, Munich, Germany) to assess regional and global annular geometry.
Mixed between-within analysis of variance showed no differences between TAVR and AVR groups in any of the mitral annular geometric indices preoperatively. However, postoperative analysis did demonstrate an effect of AVR on geometry. Patients undergoing open AVR had significant decrease in annular height, septolateral diameter, mitral valve transverse diameter, and mitral annular area after valve replacement (p ≤ 0.006). Similar changes were not noted in the TAVR group.
Mitral annular geometry is better preserved by TAVR than by AVR. Thus, TAVR may be a more physiologic approach to aortic replacement.
Objectives This study sought to compare echocardiographic findings in patients with critical aortic stenosis following surgical aortic valve replacement (SAVR) or transcatheter aortic valve ...replacement (TAVR). Background The PARTNER (Placement of Aortic Transcatheter Valves) trial randomized patients 1:1 to SAVR or TAVR. Methods Echocardiograms were obtained at baseline, discharge, 30 days, 6 months, 1 year, and 2 years after the procedure and analyzed in a core laboratory. For the analysis of post-implantation variables, the first interpretable study (≤6 months) was used. Results Both groups showed a decrease in aortic valve gradients and increase in effective orifice area (EOA) (p < 0.0001), which remained stable over 2 years. Compared with SAVR, TAVR resulted in larger indexed EOA (p = 0.038), less prosthesis-patient mismatch (p = 0.019), and more total and paravalvular aortic regurgitation (p < 0.0001). Baseline echocardiographic univariate predictors of death were lower peak transaortic gradient in TAVR patients, and low left ventricular diastolic volume, low stroke volume, and greater severity of mitral regurgitation in SAVR patients. Post-implantation echocardiographic univariate predictors of death were: larger left ventricular diastolic volume, left ventricular systolic volume and EOA, decreased ejection fraction, and greater aortic regurgitation in TAVR patients; and smaller left ventricular systolic and diastolic volumes, low stroke volume, smaller EOA, and prosthesis-patient mismatch in SAVR patients. Conclusions Patients randomized to either SAVR or TAVR experience enduring, significant reductions in transaortic gradients and increase in EOA. Compared with SAVR, TAVR patients had higher indexed EOA, lower prosthesis-patient mismatch, and more aortic regurgitation. Univariate predictors of death for the TAVR and SAVR groups differed and might allow future refinement in patient selection. (THE PARTNER TRIAL: Placement of AoRTic TraNscathetER Valve Trial; NCT00530894 )