Timing performance of small cell 3D silicon detectors Kramberger, G.; Cindro, V.; Flores, D. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
08/2019, Letnik:
934
Journal Article
Recenzirano
Odprti dostop
A silicon 3D detector with a single cell of 50 × 50 μm2 was produced and evaluated for timing applications. The measurements of time resolution were performed for 90Sr electrons with dedicated ...electronics used also for determining time resolution of Low Gain Avalanche Detectors (LGADs). The measurements were compared to those with LGADs and also simulations. The studies showed that the dominant contribution to the timing resolution comes from the time walk originating from different induced current shapes for hits over the cell area. This contribution decreases with higher bias voltages, lower temperatures and smaller cell sizes. It is around 30 ps for a 3D detector of 50 × 50 μm2 cell at 150 V and −20 °C, which is comparable to the time walk due to Landau fluctuations in LGADs. It even improves for inclined tracks and larger pads composed of multiple cells. A good agreement between measurements and simulations was obtained, thus validating the simulation results.
The upgrade of the tracking detectors for the High Luminosity-LHC (HL-LHC) requires the development of novel radiation hard silicon sensors. The development of Depleted Monolithic Active Pixel ...Sensors targets the replacement of hybrid pixel detectors with radiation hard monolithic CMOS sensors. We designed, manufactured and tested radiation hard monolithic CMOS sensors in the TowerJazz 180 nm CMOS imaging technology with small electrodes pixel designs. These designs can achieve pixel pitches well below current hybrid pixel sensors (typically 50 × 50μm) for improved spatial resolution. Monolithic sensors in our design allow to reduce multiple scattering by thinning to a total silicon thickness of only 50μm. Furthermore monolithic CMOS sensors can substantially reduce detector costs. These well-known advantages of CMOS sensor for performance and costs can only be exploited in pp-collisions at HL-LHC if the DMAPS sensors are designed to be radiation hard, capable of high hit rates and have a fast signal response to satisfy the 25 ns bunch crossing structure of LHC. Through the development of the MALTA and Mini-MALTA sensors we show the necessary steps to achieve radiation hardness at 1015 neq/cm2 for DMAPS with small electrode designs. The sensors combine high granularity (pitch 36.4x36.4μm2), low detector capacitance (<5fF/pixel) of the charge collection electrode (3μm), low noise (ENC≈10 e−) and low power operation (1μW/pixel) with a fast signal response (25 ns bunch crossing). The sensors feature arrays of 512 × 512 (MALTA) and 16 × 64 (Mini-MALTA) pixels. To cope with high hit rates expected at HL-LHC (>200 MHz/cm2) we have implemented a novel high-speed asynchronous readout architecture. The paper summarises the optimisation of the pixel design to achieve radiation hard pixel designs with full efficiency after irradiation at >98% after 1015 neq/cm2).
Measurement results of the MALTA monolithic pixel detector Schioppa, E.J.; Asensi Tortajada, I.; Berdalovic, I. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2020, Letnik:
958
Journal Article
Recenzirano
MALTA is a full scale monolithic pixel detector implemented in TowerJazz 180 nm CMOS technology. The small pixel electrode allowed for the implementation of a fast, low noise and low power front-end, ...which is sensitive to the charge released by ionizing radiation in a 20–25 μm deep depleted region. The novel asynchronous matrix architecture is designed to ensure low power consumption and high rate capability. Such features make MALTA a possible candidate for the outer layer of ATLAS Inner Tracker (ITk) upgrade. Unirradiated and irradiated MALTA sensors have been extensively tested in laboratory and with high energy particle beams. Results of this measurements campaign are shown, and the further improvements that are being implemented in the next versions of the chip are discussed.
We report results of analysis of a month‐long measurement of indoor air and environment quality parameters in one gym during sporting activities such as football, basketball, volleyball, badminton, ...boxing, and fitness. We have determined an average single person's contribution to the increase of temperature, humidity, and dust concentration in the gym air volume of 12500 m3: during 90‐min exercise performed at an average heart rate of 143 ± 10 bpm, a single person evaporated 0.94 kg of water into the air by sweating, contributed 0.03 K to the air temperature rise and added 1.5 μg/m3 and 5 ng/m3 to the indoor concentration of inhalable particles (PM10) and Ca concentration, respectively. As the breathing at the observed exercise intensity was about three times faster with respect to the resting condition and as the exercise‐induced PM10 concentration was about two times larger than outdoors, a sportsman in the gym would receive about a sixfold higher dose of PM10 inside than he/she would have received at rest outside.