Initial results from the LHCb Vertex Locator Hutchcroft, D.E.
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
08/2011, Letnik:
648
Journal Article
Recenzirano
The design and initial performance of the LHCb Vertex Locator is presented; including the construction tolerances, metrology measurements and the track resolution performance in the LHC proton–proton ...collision data.
The hadronic final states observed with the ALEPH detector at LEP in e+e- annihilation are analysed using 730 pb-1 of data collected between 91 and 209 GeV in the framework of QCD. In particular ...event-shape variables and inclusive charged particle spectra are measured. The energy evolution of quantities derived from these measurements is compared to analytic QCD predictions. The mean charged particle multiplicity, the charged particle momentum spectrum and its peak position are compared to predictions of the modified-leading-logarithmic approximation. The strong coupling constant alpha_s is determined from a fit of the QCD prediction to distributions of six event-shape variables at eight centre-of-mass energies. A study of non-perturbative power law corrections is presented
Exotic hadrons made of five quarks (pentaquarks) are searched for in hadronic Z decays collected by the ALEPH detector at LEP. No significant signal is observed. At 95% C.L., upper limits are set on ...the production rates N of such particles and their charge-conjugate state per Z decay: NΘ(1535)+⋅BR(Θ(1535)+→pKS0)<6.2×10−4,NΞ(1862)−−⋅BR(Ξ(1862)−−→Ξ−π−)<4.5×10−4,NΞ(1862)0⋅BR(Ξ(1862)0→Ξ−π+)<8.9×10−4,NΘc(3100)0⋅BR(Θc(3100)0→D*−p)<6.3×10−4,NΘc(3100)0⋅BR(Θc(3100)0→D−p)<31×10−4.
Triple gauge-boson couplings γWW and ZWW involving single-photon, single-W and W-pair production are determined using data samples collected at LEP with the ALEPH detector at centre-of-mass energies ...between 183 and 209 GeV. The integrated luminosity used is 700 pb−1 for the single-photon measurement and 683 pb−1 for the W channels. Restricting the measurement to C- and P-conserving terms and applying local SU(2)L×U(1)Y gauge invariance, the measured values of the parameters g1Z, κγ and λγ are: g1Z=1.001±0.027(stat)±0.013(syst),κγ=0.971±0.055(stat)±0.030(syst),λγ=−0.012±0.027(stat)±0.011(syst) for single-parameter fits, where the two other parameters are fixed to their Standard Model values. Results are also presented for the cases where two or all three couplings are allowed to vary.
An additional analysis using W-pair events is performed to measure the unconstrained real and imaginary parts of all 14 triple gauge-boson couplings and to perform an indirect search for a techni-ρ resonance. No deviations from the Standard Model expectations are observed and the lower limit on the techni-ρ mass is set to 600 GeV/c2 at 95% confidence level.
Aging studies for a multi-wire proportional chamber of the LHCb muon system have been performed using the CERN Gamma Irradiation Facility. The irradiated four-gap chamber corresponds to a full-size ...prototype with
1500
cm
2
sensitive area and has been operated with an Ar/CO
2/CF
4 (40:50:10) gas mixture. A linear charge of
∼0.25
C/cm
for
100
m
anode wire length has been accumulated over a period of 6 months, which corresponds to the charge collected in
5
LHCb
years. The observed aging effects do not prohibit the use of these chambers in the LHCb experiment.