A thin-walled aluminum (Al) hollow electrode has been inserted into an ion source to serve as an electrode for a radio frequency magnetron discharge. The produced plasma stabilized by argon (Ar) gas ...sputters the Al electrode to form a beam of Al(+) and Ar(+) ions. The total beam current extracted through a 3 mm diameter extraction hole has been 50 μA, with the Al(+) ion beam occupying 30% of the total beam current.
We present two results of a search for MeV-scale neutrino and anti-neutrino events correlated with gravitational wave events/candidates and large solar flares with KamLAND. The KamLAND detector is a ...large-volume neutrino detector using liquid scintillator, which is located at 1 km underground under the top of Mt. Ikenoyama in Kamioka, Japan. KamLAND has multiple reaction channels to detect neutrinos. Electron antineutrino can be detected via inverse-beta decay with 1.8 MeV neutrino energy threshold. All flavors of neutrinos can be detected via neutrino-electron scattering without neutrino energy threshold. KamLAND has continued the neutrino observation since 2002 March. We use the data set of 60 gravitational waves provided by the LIGO/Virgo collaboration during their second and third observing runs and search for coincident electron antineutrino events in KamLAND. We find no significant coincident signals within a ±500 s timing window from each gravitational wave and present 90% C.L. upper limits on the electron antineutrino fluence between 108–1013 cm-2 for neutrino energies of 1.8–111 MeV. For a solar-flare neutrino search at KamLAND, we determine the timing window using the solar X-ray data set provided by the GOES satellite series from 2002 to 2019 and search for the excess of coincident event rate on the all-flavor neutrinos. We find no significant event rate excess in the flare time windows and get 90% C.L. upper limits on the fluence of neutrinos of all flavors (electron anti-neutrinos) between 1010–1013 cm-2 (108–1013 cm-2) for neutrino energies in the energy range of 0.4–35 MeV.
Abstract
In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated from the neutron decay rate and the incident neutron flux. The flux is obtained ...by counting the protons emitted from the neutron absorption reaction of ^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ^{3}{\rm He}$ nuclei, we have suggested using the ^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy to the $^3$He(n,p)$^3$H reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement. In this paper we report the most accurate experimental value of the cross section of the $^{14}$N(n,p)$^{14}$C reaction at a neutron velocity of 2200 m s$^{-1}$, measured relative to the $^3$He(n,p)$^3$H reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the $^{17}$O(n,$\alpha$)$^{14}$C reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.
In this work, we report the results of a search for MeV-scale astrophysical neutrinos in KamLAND presented as an excess in the number of coincident neutrino interactions associated with the publicly ...available high-energy neutrino datasets from the IceCube Neutrino Observatory. We find no statistically significant excess in the number of observed low-energy electron antineutrinos in KamLAND, given a coincidence time window of ±500 s, ±1,000 s, ±3,600 s, and ±10,000 s around each of the IceCube neutrinos. We use this observation to present limits from 1.8 MeV to 100 MeV on the electron antineutrino fluence, assuming a mono-energetic flux. We then compare the results to several astrophysical measurements performed by IceCube and place a limit at the 90% confidence level on the electron antineutrino isotropic thermal luminosity from the TXS 0506+056 blazar.