Here we present a comprehensive mass cytometry analysis of peripheral innate lymphoid cell (ILC) subsets in relapsing/remitting MS (RRMS) patients prior to and after onset of cladribine tablets ...(CladT). ILC analysis was conducted on CyTOF data from peripheral blood mononuclear cells (PBMC) of MS patients before, 2 and 6 months after onset of CladT, and non-MS controls. Dimensionality reduction was used for immunophenotyping ILC subsets. CladT reduced all ILC subsets, except for CD56bright NK cells and ILC2. Furthermore, CD38+ NK cell and CCR6+ ILC3 were excluded from CladT-induced immune cell reductions. Post-CladT replenishment by immature ILC was noted by increased CD5+ ILC1 proportions at 2 months, and boosted CD38-CD56bright NK cell numbers at 6 months. CladT induce immune cell depletion among ILC but exclude CD56bright NK cells and ILC2 subsets, as well as CD38+ NK cell and CCR6+ ILC3 immunophenotypes. Post-CladT ILC expansions indicate ILC reconstitution towards a more tolerant immune system phenotype.
Dry Dilution Refrigerators (DDR) based on pulse tube cryo-coolers have started to replace Wet Dilution Refrigerators (WDR) due to the ease and low cost of operation. However these advantages come at ...the cost of increased vibrations, induced by the pulse tube. In this work, we present the vibration measurements performed on three different commercial DDRs. We describe in detail the vibration measurement system we assembled, based on commercial accelerometers, conditioner and DAQ, and examined the effects of the various damping solutions utilized on three different DDRs, both in the low and high frequency regions. Finally, we ran low temperature, pseudo-massive (30 and 250g) germanium bolometers in the best vibration-performing system under study and report on the results.
CUPID-Mo is a bolometric experiment to search for neutrinoless double-beta decay (
0
ν
β
β
) of
100
Mo
. In this article, we detail the CUPID-Mo detector concept, assembly and installation in the ...Modane underground laboratory, providing results from the first datasets. The CUPID-Mo detector consists of an array of 20
100
Mo
-enriched 0.2 kg
Li
2
MoO
4
crystals operated as scintillating bolometers at
∼
20
mK
. The
Li
2
MoO
4
crystals are complemented by 20 thin Ge optical bolometers to reject
α
events by the simultaneous detection of heat and scintillation light. We observe a good detector uniformity and an excellent energy resolution of 5.3 keV (6.5 keV) FWHM at 2615 keV, in calibration (physics) data. Light collection ensures the rejection of
α
particles at a level much higher than 99.9% – with equally high acceptance for
γ
/
β
events – in the region of interest for
100
Mo
0
ν
β
β
. We present limits on the crystals’ radiopurity:
≤
3
μ
Bq/kg
of
226
Ra
and
≤
2
μ
Bq/kg
of
232
Th
. We discuss the science reach of CUPID-Mo, which can set the most stringent half-life limit on the
100
Mo
0
ν
β
β
decay in half-a-year’s livetime. The achieved results show that CUPID-Mo is a successful demonstrator of the technology developed by the LUMINEU project and subsequently selected for the CUPID experiment, a proposed follow-up of CUORE, the currently running first tonne-scale bolometric
0
ν
β
β
experiment.
The future
Ricochet
experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) ...process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the
Ricochet
Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the
Ricochet
neutron background characterization using
3
He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the
Ricochet
Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future
Ricochet
experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the
Ricochet
experiment should reach a statistical significance of 4.6 to 13.6
σ
for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.
We report the measurement of the two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The ...detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of $^{100}$Mo is determined to be $T_{1/2}^{2\nu}=7.12^{+0.18}_{-0.14}\,\mathrm{(stat.)}\pm0.10\,\mathrm{(syst.)}\times10^{18}$ years. This is the most accurate determination of the $2\nu\beta\beta$ half-life of $^{100}$Mo to date. We also confirm, with the statistical significance of $>3\sigma$, that the single-state dominance model of the $2\nu\beta\beta$ decay of $^{100}$Mo is favored over the high-state dominance model.
We present the noise performance of high electron mobility transistors (HEMT) developed by CNRS/C2N laboratory. Various HEMT’s gate geometries with 2 pF to 230 pF input capacitance have been studied ...at 4 K. A model for both voltage and current noises has been developed with frequency dependence up to 1 MHz. These HEMTs exhibit low dissipation, excellent noise performance and can advantageously replace traditional Si-JFETs for the readout of high impedance thermal sensor and semiconductor ionization cryogenic detectors. Our model predicts that cryogenic germanium detectors of 30 g with 10 eV heat and 20 eV
ee
baseline resolution are feasible if read out by HEMT-based amplifiers. Such resolution allows for high discrimination between nuclear and electron recoils at low threshold. This capability is of major interest for coherent elastic neutrino scattering and low-mass dark matter experiments such as Ricochet and EDELWEISS.
The necessity to increase exposure in rare event search experiments by maintaining a low energy threshold and a good energy resolution leads to segmented detectors as in EDELWEISS (Dark Matter), ...CUORE (0
ν
β
β
) or Ricochet (CENNS) for example. However, the large number of sub-elements can dramatically increase the complexity of such detector arrays. In this work we report on our progress towards designing a flexible detector technology based on Kinetic Inductance Detector (KID) resonators evaporated on massive target crystals readout by a contact-less feedline. Providing that we achieve
O
(
100
)
eV energy threshold, such approach could easily be scaled to tens of kilogram detector arrays thanks to the intrinsic multiplexing capability of KIDs. Using a 30 g silicon target absorber with Al/Ti multi layers for the KID resonator, we report a significant improvement of our detector response exhibiting a keV-scale energy resolution combined with the absence of position dependence on the event location. Indeed, compared to our previous work, we are now able to properly identify calibration lines from surface (20 keV X-rays) and bulk events (60 keV gamma rays). This significant improvement is an important step towards a better understanding of phonons and quasiparticles dynamics, which is pivotal in optimizing this technology.