Objective
Evidence on the impact of leisure time physical activity (LTPA) in pregnancy on birth size is inconsistent. We aimed to examine the association between LTPA during early and late pregnancy ...and newborn anthropometric outcomes.
Design
Individual level meta‐analysis, which reduces heterogeneity across studies.
Setting
A consortium of eight population‐based studies (seven European and one US) comprising 72 694 participants.
Methods
Generalised linear models with consistent inclusion of confounders (gestational age, sex, parity, maternal age, education, ethnicity, BMI, smoking, and alcohol intake) were used to test associations between self‐reported LTPA at either early (8–18 weeks gestation) or late pregnancy (30+ weeks) and the outcomes. Results were pooled using random effects meta‐analyses.
Main outcome measures
Birth weight, large‐for‐gestational age (LGA), macrosomia, small‐for‐gestational age (SGA), % body fat, and ponderal index at birth.
Results
Late, but not early, gestation maternal moderate to vigorous physical activity (MVPA), vigorous activity, and LTPA energy expenditure were modestly inversely associated with BW, LGA, macrosomia, and ponderal index, without heterogeneity (all: I2 = 0%). For each extra hour/week of MVPA, RR for LGA and macrosomia were 0.97 (95% CI: 0.96, 0.98) and 0.96 (95% CI: 0.94, 0.98), respectively. Associations were only modestly reduced after additional adjustments for maternal BMI and gestational diabetes. No measure of LTPA was associated with risk for SGA.
Conclusions
Physical activity in late, but not early, pregnancy is consistently associated with modestly lower risk of LGA and macrosomia, but not SGA.
Tweetable
In an individual participant meta‐analysis, late pregnancy moderate to vigorous physical activity modestly reduced birth size outcomes.
Tweetable
In an individual participant meta‐analysis, late pregnancy moderate to vigorous physical activity modestly reduced birth size outcomes.
Abstract
The experimental requirements in current and near-future accelerators and experiments have stimulated intense interest in R&D of detectors with high precision timing capabilities, resulting ...in novel instrumentation. During the R&D phase, the timing information is usually extracted from the signal using the full waveform collected with fast oscilloscopes; this method produces a large amount of data and it becomes impractical when the detector has many channels. Towards practical applications, the data acquisition should be undertaken by dedicated front-end electronic units. The selected technology should retain the signal timing characteristics and consequently the timing resolution on the particle’s arrival time. We investigate the adequacy of the Leading-edge discrimination timing technique to achieve timing with a precision in the order of tens of picosecond with novel gaseous detectors. The method under investigation introduces a “time-walk” which impinges on the timing resolution. We mitigate the effect of time-walk using three different approaches; the first based on multiple Time-over-Threshold, the second based on multiple Charge-over-Threshold information and the third uses artificial Neural Network techniques. The results of this study prove the feasibility of the methods and their ability to achieve a timing resolution comparable to that obtained using the full waveforms.
Abstract
The application of muon tomography method in small scale, for the imaging of a five-centimeter side lead cube, is being examined in the present work. The representation of the object is ...being achieved by using the transmission muography technique, in which the “free-sky” muon flux is compared to the muon flux measured within the acceptance of the detector. This comparison yields information about the absorption of the muons as they pass through the object under investigation. Also, a projective reconstruction method called “Back Projection” is tested by being applied on the data, providing information about the location of the object and its dimensions. This project has been carried out within the frame of EKATY programme, which aims to the innovative imaging of the subsurface of archaeological sites and the interior of structural elements of monuments in three and four dimensions.
On-chip energy storage and management will have transformative impacts in developing advanced electronic platforms with built-in energy needs for operation of integrated circuits driving a ...microprocessor. Though success in growing stand-alone energy storage elements such as electrochemical capacitors (super and pseusocapacitors) on a variety of substrates is a promising step towards this direction. In this work, on-chip energy storage is demonstrated using architectures of highly aligned vertical carbon nanotubes (CNTs) acting as supercapacitors, capable of providing large device capacitances. The efficiency of these structures is further increased by incorporating electrochemically active nanoparticles such as MnO
to form pseudocapacitive architectures thus enhancing device capacitance areal specific capacitance of 37 mF/cm
. The demonstrated on-chip integration is up and down-scalable, compatible with standard CMOS processes, and offers lightweight energy storage what is vital for portable and autonomous device operation with numerous advantages as compared to electronics built from discrete components.
Timing performance of a Micro-Channel-Plate Photomultiplier Tube Bortfeldt, J.; Brunbauer, F.; David, C. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
04/2020, Letnik:
960, Številka:
C
Journal Article
Recenzirano
Odprti dostop
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a ...GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r<5.5 mm) the time resolution of the two MCP-PMTs combined is better than 10 ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTs as t0 reference detectors has been validated.
Abstract
Within the frame of the EKATϒ programme, whose purpose is the innovative imaging of the subsurface of archaeological sites and the interior of structural elements of monuments in “three” and ...“four” dimensions, the applicability of Muon Tomography technique in the representation of a tumulus is tested in the present work. The scanning of its internal structure is accomplished by measuring the flux deficit of cosmic muon tracks in the presence of an object inside the tumulus, compared to the muon flux when traversing a uniform tumulus (transmission muography). The feasibility study of the method is achieved with a simulation of the tumulus geometry and the structure under investigation. Following the simulation process, a tracking telescope, consisting of four MicroMegas detectors and two trigger plastic scintillators, will be placed near Apollonia’s tumulus to collect data. For the specific latitude where the Apollonia’s tumulus is located, the energy and angular muon distribution at sea level is studied. Implementing the dimensions of the telescope in the simulation, the back-projection method is examined for the localization of the hidden object and the estimation of its dimensions. The method is tested for the telescope optimal position, placed under the tumulus, and the realistic one, placed near the tumulus at the level of its base.
Timing performance of a multi-pad PICOSEC-Micromegas detector prototype Aune, S.; Bortfeldt, J.; Brunbauer, F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/2021, Letnik:
993, Številka:
C
Journal Article
Recenzirano
Odprti dostop
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four ...representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we measure a time resolution of approximately 25 picoseconds for charged particles hitting near the anode pad centres, and up to 30 picoseconds at the pad edges. Here, we study in detail the effect of drift gap thickness non-uniformity on the timing performance and evaluate impact position based corrections to obtain a uniform timing response over the full detector coverage.