One of the important challenges in condensed matter science is to understand ultrafast, atomic-scale fluctuations that dictate dynamic processes in equilibrium and non-equilibrium materials. Here, we ...report an important step towards reaching that goal by using a state-of-the-art perfect crystal based split-and-delay system, capable of splitting individual X-ray pulses and introducing femtosecond to nanosecond time delays. We show the results of an ultrafast hard X-ray photon correlation spectroscopy experiment at LCLS where split X-ray pulses were used to measure the dynamics of gold nanoparticles suspended in hexane. We show how reliable speckle contrast values can be extracted even from very low intensity free electron laser (FEL) speckle patterns by applying maximum likelihood fitting, thus demonstrating the potential of a split-and-delay approach for dynamics measurements at FEL sources. This will enable the characterization of equilibrium and, importantly also reversible non-equilibrium processes in atomically disordered materials.
We measured the transverse and longitudinal coherence properties of the Linac Coherent Light Source (LCLS) at SLAC in the hard x-ray regime at 9 keV photon energy on a single shot basis. Speckle ...patterns recorded in the forward direction from colloidal nanoparticles yielded the transverse coherence properties of the focused LCLS beam. Speckle patterns from a gold nanopowder recorded with atomic resolution allowed us to measure the shot-to-shot variations of the spectral properties of the x-ray beam. The focused beam is in the transverse direction fully coherent with a mode number close to 1. The average number of longitudinal modes behind the Si(111) monochromator is about 14.5 and the average coherence time τ(c)=(2.0±1.0) fc. The data suggest a mean x-ray pulse duration of (29±14) fs behind the monochromator for (100±14) fc electron pulses.
The PERCIVAL detector: first user experiments Correa, J.; Mehrjoo, M.; Battistelli, R. ...
Journal of synchrotron radiation,
January 2023, 2023-Jan-01, 2023-01-01, 20230101, 2023, Letnik:
30, Številka:
1
Journal Article
Recenzirano
Odprti dostop
The PERCIVAL detector is a CMOS imager designed for the soft X‐ray regime at photon sources. Although still in its final development phase, it has recently seen its first user experiments: ...ptychography at a free‐electron laser, holographic imaging at a storage ring and preliminary tests on X‐ray photon correlation spectroscopy. The detector performed remarkably well in terms of spatial resolution achievable in the sample plane, owing to its small pixel size, large active area and very large dynamic range; but also in terms of its frame rate, which is significantly faster than traditional CCDs. In particular, it is the combination of these features which makes PERCIVAL an attractive option for soft X‐ray science.
PERCIVAL is a detector system specifically designed for the soft X‐ray regime. Although still in a development phase, it has already served its first user experiments at both a storage ring and also a free‐electron laser. The device performed remarkably well in all the different techniques tested: ptychography, holography and also X‐ray photon correlation spectroscopy. The results of these tests are presented.
The single shot based coherence properties of hard x-ray pulses from the Linac Coherent Light Source (LCLS) were measured by analyzing coherent diffraction patterns from nano-particles and gold ...nanopowder. The intensity histogram of the small angle x-ray scattering ring from nano-particles reveals the fully transversely coherent nature of the LCLS beam with a number of transverse mode 〈Ms〉 = 1.1. On the other hand, the speckle contrasts measured at a large wavevector yields information about the longitudinal coherence of the LCLS radiation after a silicon (111) monochromator. The quantitative agreement between our data and the simulation confirms a mean coherence time of 2.2 fs and a x-ray pulse duration of 29 fs. Finally the observed reduction of the speckle contrast generated by x-rays with pulse duration longer than 30 fs indicates ultrafast dynamics taking place at an atomic length scale prior to the permanent sample damage.
Abstract
We show the results of speckle contrast analysis at the MID instrument of European XFEL in the hard X-ray regime. Speckle patterns measured from static colloidal samples are compared to ...results previously obtained at the SPB/SFX instrument. A high degree of coherence of 0.79 is obtained by modelling the
q
-dependence of the speckle contrast, that corresponds to a number of coherent modes of
M
= 1.7. Furthermore, the variation of contrast over many pulse trains is exceptional low, resulting in a degree of coherence with a relative standard deviation below 0.1. Our results demonstrate the high stability of coherence properties at European XFEL over many X-ray pulses and pulse trains which is a prerequisite for coherence-based techniques such as MHz X-ray photon correlation spectroscopy.
We applied shear to a silica nanoparticle dispersion in a microfluidic jet device and observed direction-dependent structure along and across the flow direction. The asymmetries of the diffraction ...patterns were evaluated by x-ray cross correlation analysis. For different Rayleigh nozzle sizes and shapes, we measured the decay of the shear-induced ordering after the cessation of the shear. At large tube sizes and small shear rates, the characteristic times of the decay become longer, but Péclet-weighted times do not scale linearly with Péclet numbers. By modeling particle distributions with the corresponding diffraction patterns and comparing measured shape asymmetry to simulations, we determined the variation of volume fraction over the azimuthal angle for the maximum ordered state in the jet.