Chinese herbal medicine Jinlianqingre Effervescent Tablets (JET) are the recommended control measure for uncomplicated hand, foot, and mouth disease (HFMD) by the Ministry of Health of China. ...However, high-quality evidence to support this recommendation is limited. A total of 288 patients ranging in age from 1 to 13 years were randomly assigned to JET in combination with conventional therapy (mainly including the reduction of temperature by applying physical cooling paste or warm bathing), or conventional therapy with placebo group for 7 days. The objective was to test the hypothesis that JET combination therapy is more effective than conventional therapy for uncomplicated HFMD. A randomized, double-blind, placebo-controlled trial was designed. Our study showed that, compared with conventional therapy, the median time to fever resolution was significantly shorter in the JET combination therapy (8 vs. 80 h;
p
< 0.0001); the risk of fever resolution increased in the JET combination therapy hazard ratio, 19.8; 95 % confidence interval (CI), 12.8 to 30.7; the median healing time of rash or oral ulcer was significantly shorter in the JET combination therapy (14 vs. 74 h;
p
< 0.0001); and the median symptom score for skin or oral mucosa lesions improved more rapidly in the JET combination therapy during the follow-up period. The median duration of hospital stay was 6 days in the JET combination therapy and 7 days in the conventional therapy (
p
< 0.0001). No significant adverse events and complications were found in both groups. The addition of JET to conventional therapy reduced fever clearance time, healing time of skin or oral mucosa lesions, and duration of hospital stay in children with uncomplicated HFMD.
Abstract
We present the second release of value-added catalogues of the LAMOST Spectroscopic Survey of the Galactic Anticentre (LSS-GAC DR2). The catalogues present values of radial velocity Vr, ...atmospheric parameters – effective temperature Teff, surface gravity log g, metallicity Fe/H, α-element to iron (metal) abundance ratio α/Fe (α/M), elemental abundances C/H and N/H and absolute magnitudes MV and $M_{K_{\rm s}}$ deduced from 1.8 million spectra of 1.4 million unique stars targeted by the LSS-GAC since 2011 September until 2014 June. The catalogues also give values of interstellar reddening, distance and orbital parameters determined with a variety of techniques, as well as proper motions and multiband photometry from the far-UV to the mid-IR collected from the literature and various surveys. Accuracies of radial velocities reach 5 km s−1 for the late-type stars, and those of distance estimates range between 10 and 30 per cent, depending on the spectral signal-to-noise ratios. Precisions of Fe/H, C/H and N/H estimates reach 0.1 dex, and those of α/Fe and α/M reach 0.05 dex. The large number of stars, the contiguous sky coverage, the simple yet non-trivial target selection function and the robust estimates of stellar radial velocities and atmospheric parameters, distances and elemental abundances make the catalogues a valuable data set to study the structure and evolution of the Galaxy, especially the solar-neighbourhood and the outer disc.
As a major component of the LAMOST Galactic surveys, the LAMOST Spectroscopic Survey of the Galactic Anticentre (LSS-GAC) aims to survey a significant volume of the Galactic thin/thick discs and halo ...for a contiguous sky area of over 3400 deg2 centred on the Galactic anticentre (|b| ≤ 30°, 150 ≤ l ≤ 210°), and obtain λλ3700–9000 low-resolution (R ∼ 1800) spectra for a statistically complete sample of ∼3 M stars of all colours down to a limiting magnitude of r ∼ 17.8 mag (to 18.5 mag for limited fields). Together with Gaia, the LSS-GAC will yield a unique data set to advance our understanding of the structure and assemblage history of the Galaxy, in particular its disc(s). In addition to the main survey, the LSS-GAC will also target hundreds of thousands objects in the vicinity fields of M 31 and M 33 and survey a significant fraction (over a million) of randomly selected very bright stars (r ≤ 14 mag) in the Northern hemisphere. During the Pilot and the first year Regular Surveys of LAMOST, a total of 1042 586 750 867 spectra of a signal-to-noise ratio S/N(7450 Å) ≥ 10 S/N(4650 Å) ≥ 10 have been collected. In this paper, we present a detailed description of the target selection algorithm, survey design, observations and the first data release of value-added catalogues (including radial velocities, effective temperatures, surface gravities, metallicities, values of interstellar extinction, distances, proper motions and orbital parameters) of the LSS-GAC.
We present a novel surface-enhanced Raman scattering (SERS) substrate based on graphene oxide/silver nanoparticles/silicon pyramid arrays structure (GO/Ag/PSi). The SERS behaviors are discussed and ...compared by the detection of R6G. Based on the contrast experiments with PSi, GO/PSi, Ag/PSi and GO/AgA/PSi as SERS substrate, the perfect bio-compatibility, good homogeneity and chemical stability were confirmed. We also calculated the electric field distributions using Finite-difference time-domain (FDTD) analysis to further understand the GO/Ag/PSi structure as a perfect SERS platform. These experimental and theoretical results imply that the GO/Ag/PSi with regular pyramids array is expected to be an effective substrate for label-free sensitive SERS detections in areas of medicine, food safety and biotechnology.
A nasopharyngeal carcinoma (NPC) mass screening trial using a combination of immunoglobulin A antibodies to Epstein-Barr virus capsid antigen and nuclear antigen-1 by enzyme-linked immunosorbent ...assay in addition to indirect mirror examination in the nasopharynx and/or lymphatic palpation (IMLP) was conducted in southern China. Cantonese aged 30-59 years residing in 2 cities randomly selected by cluster sampling, Sihui and Zhongshan, were invited to participate in this screening from May 2008 through May 2010. Participants were offered fiberoptic endoscopy examination and/or pathologic biopsy if their serologic tests reached our predefined level of high risk or if results from the physical examination indicated possible cancer (i.e., were IMLP positive). A total of 28,688 individuals were voluntarily screened in the initial round. The overall NPC detection rate was 0.14% (41/28,688) with an early diagnosis rate of 68.3% (28/41) during the first year of follow-up. Thirty-eight of 41 cases (92.7%) were detected among the high-risk group, and 7 of 41 cases (17.1%) were detected among the IMLP-positive group. The 2 Epstein-Barr virus serologic tests by enzyme-linked immunosorbent assay could be a feasible alternative for NPC screening in endemic areas. Further follow-up is needed to examine whether screening has an effect on decreasing mortality from NPC in these areas.
Alzheimer's disease (AD), the most common type of irreversible dementia, is predicted to affect 152 million people by 2050. Evidence from large-scale preventive randomized controlled trials (RCTs) on ...modifiable risk variables in Europe has shown that multi-domain lifestyle treatments for older persons at high risk of dementia may be practical and effective. Given the substantial differences between the Chinese and European populations in terms of demographics and living conditions, direct adoption of the European program in China remains unfeasible. Although a RCT has been conducted in China previously, its participants were mainly from rural areas in northern China and, thus, are not representative of the entire nation.There is an urgent need to establish cohorts that represent different economic, cultural, and geographical situations in order to explore implementation strategies and evaluate the effects of early multi-domain interventions more comprehensively and accurately.
We developed an integrated intervention procedure implemented in urban neighborhood settings, namely China Initiative for Multi-Domain Intervention (CHINA-IN-MUDI). CHINA-IN-MUDI is a 2-year multicenter open-label cluster-randomised controlled trial centered around a Chinese-style multi-domain intervention to prevent cognitive decline. Participants aged 60-80 years were recruited from a nationally representative study, i.e. China Healthy Aging and Dementia Study cohort. An external harmonization process was carried out to preserve the original FINGER design. Subsequently, we standardized a series of Chinese-style intervention programs to align with cultural and socioeconomic status. Additionally, we expanded the secondary outcome list to include genomic and proteomic analyses. To enhance adherence and facilitate implementation, we leveraged an e-health application.
Screening commenced in July 2022. Currently, 1,965 participants have been randomized into lifestyle intervention (n = 772) and control groups (n = 1,193). Both the intervention and control groups exhibited similar baseline characteristics. Several lifestyle and vascular risk factors were present, indicating a potential window of opportunity for intervention. The intervention will be completed by 2025.
This project will contribute to the evaluation of the effectiveness and safety of intervention strategies in controlling AD risk and reducing clinical events, providing a basis for public health decision-making in China.
ABSTRACT
High time resolution and accuracy are of critical importance in the studies of timing analysis and time delay localization of gamma-ray bursts (GRBs), soft gamma-ray repeaters (SGRs) and ...pulsars. The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) consisting of two micro-satellites, GECAM-A and GECAM-B, launched on 2020 December 10, is aimed at monitoring and locating X-ray and GRBs all over the sky. To achieve its scientific goals, GECAM is designed to have the highest time resolution (0.1 $\mu {\rm s}$) among all GRB detectors ever flown. Here, we make a comprehensive time calibration campaign including both on-ground and on-orbit tests to derive not only the relative time accuracy of GECAM satellites and detectors, but also the absolute time accuracy of GECAM-B. Using the on-ground calibration with a $\rm ^{22}Na$ radioactive source, we find that the relative time accuracy between GECAM-A and GECAM-B is about 0.15 $\mu {\rm s}$ (1σ). To measure the relative time accuracy between all detectors of a single GECAM satellite, cosmic-ray events detected on orbit are utilized since they could produce many secondary particles simultaneously record by multiple detectors. We find that the relative time accuracy among all detectors onboard GECAM-B is about 0.12 $\mu {\rm s}$ (1σ). Finally, we use the novel Li-CCF method to perform the absolute time calibration with Crab pulsar and SGR J1935+2154, both of which were jointly observed by GECAM-B and Fermi/GBM, and obtain that the time difference between GECAM-B and Fermi/GBM is 3.06 ± 6.04 $\mu {\rm s}$ (1σ).