Dynamic contrast enhanced MRI (DCE-MRI) is a useful method to monitor therapy assessment in malignancies but must be reliable and comparable for successful clinical use. The aim of this study was to ...evaluate the inter- and intrarater reproducibility of DCE-MRI in lung cancer. At this IRB approved single centre study 40 patients with lung cancer underwent up to 5 sequential DCE-MRI examinations. DCE-MRI were performed using a 3.0T system. The volume transfer constant Ktrans was assessed by three readers using the two-compartment Tofts model. Inter- and intrarater reliability and agreement was calculated by wCV, ICC and their 95% confident intervals. DCE-MRI allowed a quantitative measurement of Ktrans in 107 tumors where 91 were primary carcinomas or intrapulmonary metastases and 16 were extrapulmonary metastases. Ktrans showed moderate to good interrater reliability in overall measurements (ICC 0.716-0.841; wCV 30.3-38.4%). Ktrans in pulmonary lesions ≥ 3 cm showed a good to excellent reliability (ICC 0.773-0.907; wCV 23.0-29.4%) compared to pulmonary lesions < 3 cm showing a moderate to good reliability (ICC 0.710-0.889; wCV 31.6-48.7%). Ktrans in intrapulmonary lesions showed a good reliability (ICC 0.761-0.873; wCV 28.9-37.5%) compared to extrapulmonary lesions with a poor to moderate reliability (ICC 0.018-0.680; wCV 28.1-51.8%). The overall intrarater agreement was moderate to good (ICC 0.607-0.795; wCV 24.6-30.4%). With Ktrans, DCE MRI offers a reliable quantitative biomarker for early non-invasive therapy assessment in lung cancer patients, but with a coefficient of variation of up to 48.7% in smaller lung lesions.
Parameters of myocardial deformation have been suggested to be superior to conventional measures of ventricular function in patients with tetralogy of Fallot (ToF), but have required non-routine, ...tagged cardiovascular magnetic resonance (CMR) techniques. We assessed biventricular myocardial function using CMR cine-based feature tracking (FT) and compared it to speckle tracking echocardiography (STE) and to simple endocardial border delineation (EBD). In addition, the relation between parameters of myocardial deformation and clinical parameters was assessed.
Overall, 28 consecutive adult patients with repaired ToF (age 40.4 ± 13.3 years) underwent standard steady-state-free precession sequence CMR, echocardiography, and cardiopulmonary exercise testing. In addition, 25 healthy subjects served as controls. Myocardial deformation was assessed by CMR based FT (TomTec Diogenes software), CMR based EBD (using custom written software) and STE (TomTec Cardiac Performance Analysis software).
Feature tracking was feasible in all subjects. A close agreement was found between measures of global left (LV) and right ventricular (RV) global strain. Interobserver agreement for FT and STE was similar for longitudinal LV global strain, but FT showed better inter-observer reproducibility than STE for circumferential or radial LV and longitudinal RV global strain. Reproducibility of regional strain on FT was, however, poor. The relative systolic length change of the endocardial border measured by EBD yielded similar results to FT global strain. Clinically, biventricular longitudinal strain on FT was reduced compared to controls (P < 0.0001) and was related to the number of previous cardiac operations. In addition, FT derived RV strain was related to exercise capacity and VE/VCO2-slope.
Although neither the inter-study reproducibility nor accuracy of FT software were investigated, and its inter-observer reproducibility for regional strain calculation was poor, its calculations of global systolic strain showed similar or better inter-oberver reproducibility than those by STE, and could be applied across RV image regions inaccessible to echo. 'Global strain' calculated by EBD gave similar results to FT. Measurements made using FT related to exercise tolerance in ToF patients suggesting that the approach could have clinical relevance and deserves further study.
Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) represents the gold standard for assessment of myocardial viability. The purpose of this study was to investigate the ...clinical potential of Compressed SENSE (factor 5) accelerated free-breathing three-dimensional (3D) whole heart LGE with high isotropic spatial resolution (1.4 mm
acquired voxel size) compared to standard breath-hold LGE imaging.
This was a retrospective, single-center study of 70 consecutive patients (45.8 ± 18.1 years, 27 females; February-November 2019), who were referred for assessment of left ventricular myocardial viability and received free-breathing and breath-hold LGE sequences at 1.5 T in clinical routine. Two radiologists independently evaluated global and segmental LGE in terms of localization and transmural extent. Readers scored scans regarding image quality (IQ), artifacts, and diagnostic confidence (DC) using 5-point scales (1 non-diagnostic-5 excellent/none). Effects of heart rate and body mass index (BMI) on IQ, artifacts, and DC were evaluated with ordinal logistic regression analysis.
Global LGE (n = 33) was identical for both techniques. Using free-breathing LGE (average scan time: 04:33 ± 01:17 min), readers detected more hyperenhanced lesions (28.2% vs. 23.5%, P < .05) compared to breath-hold LGE (05:15 ± 01:23 min, P = .0104), pronounced at subepicardial localization and for 1-50% of transmural extent. For free-breathing LGE, readers graded scans with good/excellent IQ in 80.0%, with low-impact/no artifacts in 78.6%, and with good/high DC in 82.1% of cases. Elevated BMI was associated with increased artifacts (P = .0012) and decreased IQ (P = .0237). Increased heart rate negatively influenced artifacts (P = .0013) and DC (P = .0479) whereas IQ (P = .3025) was unimpaired.
In a clinical setting, free-breathing Compressed SENSE accelerated 3D high isotropic spatial resolution whole heart LGE provides good to excellent image quality in 80% of scans independent of heart rate while enabling improved depiction of small and particularly non-ischemic hyperenhanced lesions in a shorter scan time than standard breath-hold LGE.
Desmoid tumors are a rare form of cancer, which show locally aggressive invasion of surrounding tissues and may occur anywhere in the body. Treatment options comprise conservative watch and wait ...strategies as tumors may show spontaneous regression as well as surgical resection, radiation therapy, nonsteroidal anti-inflammatory drugs (NSAID), chemotherapy, or local thermoablative approaches for progressive disease. The latter comprises cryotherapy, radiofrequency, microwave ablation, or thermal ablation with high intensity focused ultrasound (HIFU) as the only entirely non-invasive option. This report presents a case where a desmoid tumor at the left dorsal humerus was 2 times surgically resected and, after recurrence, thermally ablated with HIFU under magnetic resonance image-guidance (MR-HIFU). In our report, we analyze tumor volume and/or pain score during standard of care (2 years) and after HIFU treatment over a 4-year follow-up period. Results showed MR-HIFU treatment led to complete tumor remission and pain response.
The aim of this study was to evaluate the diagnostic potential of a novel cardiovascular magnetic resonance (CMR) based multiparametric imaging approach in suspected myocarditis and to compare it to ...traditional Lake Louise criteria (LLC).
CMR data from 67 patients with suspected acute myocarditis were retrospectively analyzed. Seventeen age- and gender-matched healthy subjects served as control. T2-mapping data were acquired using a Gradient-Spin-Echo T2-mapping sequence in short-axis orientation. T2-maps were segmented according to the 16-segments AHA-model and segmental T2 values and pixel-standard deviation (SD) were recorded. Afterwards, the parameters maxT2 (the highest segmental T2 value) and madSD (the mean absolute deviation (MAD) of the pixel-SDs) were calculated for each subject. Cine sequences in three long axes and a stack of short-axis views covering the left and right ventricle were analyzed using a dedicated feature tracking algorithm.
A multiparametric imaging model containing madSD and LV global circumferential strain (GCS
) resulted in the highest diagnostic performance in receiver operating curve analyses (area under the curve AUC 0.84) when compared to any model containing a single imaging parameter or to LLC (AUC 0.79). Adding late gadolinium enhancement (LGE) to the model resulted in a further increased diagnostic performance (AUC 0.93) and yielded the highest diagnostic sensitivity of 97% and specificity of 77%.
A multiparametric CMR imaging model including the novel T2-mapping derived parameter madSD, the feature tracking derived strain parameter GCS
and LGE yields superior diagnostic sensitivity in suspected acute myocarditis when compared to any imaging parameter alone and to LLC.
To quantitatively and qualitatively assess abdominal arterial and venous phase contrast-enhanced spectral detector computed tomography (SDCT) virtual mono-energetic (MonoE) datasets in comparison to ...conventional CT reconstructions provided by the same system.
Conventional and MonoE images at 40-120 kilo-electron volt (keV) levels with a 10 keV increment as well as 160 and 200 keV were reconstructed in abdominal SDCT datasets of 55 patients. Attenuation, image noise, and contrast- / signal-to-noise ratios (CNR, SNR) of vessels and solid organs were compared between MonoE and conventional reconstructions. Two readers assessed contrast conditions, detail visualization, overall image quality and subjective image noise with both, fixed and adjustable window settings.
Attenuation, CNR and SNR of vessels and solid organs showed a stepwise increase from high to low keV reconstructions in both contrast phases while image noise stayed stable at low keV MonoE reconstruction levels. Highest levels were found at 40 keV MonoE reconstruction (p<0.001), respectively. Solid abdominal organs showed a stepwise decrease from low to high energy levels in regard to attenuation, CNR and SNR with significantly higher values at 40 and 50 keV, compared to conventional images. The 70 keV MonoE was comparable to conventional poly-energetic reconstruction (p≥0.99). Subjective analysis displayed best image quality for the 70 keV MonoE reconstruction level in both phases at fixed standard window presets and at 40 keV if window settings could be adjusted.
SDCT derived low keV MonoE showed markedly increased CNR and SNR values due to constantly low image noise values over the whole energy spectrum from 40 to 200 keV.
The extrinsic foot muscles are essentially for controlling the movement path but our knowledge of their behavior during prolonged running is still very limited. Therefore, this study analyzed the ...time-course of muscle activation using T2 mapping during 75 min of running. In this prospective study, 19 recreational active runners completed 75 min of treadmill running at a constant speed. Interleaved T2 mapping sequences were acquired and segmented at timepoints 0, 2.5, 5, 10, 15, 45, and 75 min. ANOVA for repeated measurements followed by a Tukey post hoc test and Pearson correlation between running speed and initial signal increase at 2.5 min were calculated. All muscles showed a significant signal increase between baseline and 2.5 min (e.g. medial gastrocnemius: + 15.48%; p < 0.01). This was followed by a plateau phase till 15 min for all but the extensor digitorum longus muscle and a significant decrease at 45 or 75 min for all muscles (all p < 0.05). Correlation between running speed and signal increase was negative for all muscles and significant for both gastrocnemii (e.g. medial: r = - 0.57, p = 0.0104) and soleus (r = - 0.47, p = 0.0412). The decrease of relaxation times times in the later running phases was less pronounced for faster runners (≥ 10 km/h). T2 relaxation times do not only decrease after cessation of exercise but already during prolonged running. The lesser initial increase and later decrease in faster runners may indicate training induced changes.
The purpose of the present study was to investigate the diagnostic value of T2-mapping in acute myocarditis (ACM) and to define cut-off values for edema detection.
Cardiovascular magnetic resonance ...(CMR) data of 31 patients with ACM were retrospectively analyzed. 30 healthy volunteers (HV) served as a control. Additionally to the routine CMR protocol, T2-mapping data were acquired at 1.5 T using a breathhold Gradient-Spin-Echo T2-mapping sequence in six short axis slices. T2-maps were segmented according to the 16-segments AHA-model and segmental T2 values as well as the segmental pixel-standard deviation (SD) were analyzed.
Mean differences of global myocardial T2 or pixel-SD between HV and ACM patients were only small, lying in the normal range of HV. In contrast, variation of segmental T2 values and pixel-SD was much larger in ACM patients compared to HV. In random forests and multiple logistic regression analyses, the combination of the highest segmental T2 value within each patient (maxT2) and the mean absolute deviation (MAD) of log-transformed pixel-SD (madSD) over all 16 segments within each patient proved to be the best discriminators between HV and ACM patients with an AUC of 0.85 in ROC-analysis. In classification trees, a combined cut-off of 0.22 for madSD and of 68 ms for maxT2 resulted in 83% specificity and 81% sensitivity for detection of ACM.
The proposed cut-off values for maxT2 and madSD in the setting of ACM allow edema detection with high sensitivity and specificity and therefore have the potential to overcome the hurdles of T2-mapping for its integration into clinical routine.
Cerebrospinal fluid (CSF) dynamics in the cervical spinal subarachnoid space (SSS) have been thought to be important to help diagnose and assess craniospinal disorders such as Chiari I malformation ...(CM). In this study we obtained time-resolved three directional velocity encoded phase-contrast MRI (4D PC MRI) in three healthy volunteers and four CM patients and compared the 4D PC MRI measurements to subject-specific 3D computational fluid dynamics (CFD) simulations. The CFD simulations considered the geometry to be rigid-walled and did not include small anatomical structures such as nerve roots, denticulate ligaments and arachnoid trabeculae. Results were compared at nine axial planes along the cervical SSS in terms of peak CSF velocities in both the cranial and caudal direction and visual interpretation of thru-plane velocity profiles. 4D PC MRI peak CSF velocities were consistently greater than the CFD peak velocities and these differences were more pronounced in CM patients than in healthy subjects. In the upper cervical SSS of CM patients the 4D PC MRI quantified stronger fluid jets than the CFD. Visual interpretation of the 4D PC MRI thru-plane velocity profiles showed greater pulsatile movement of CSF in the anterior SSS in comparison to the posterior and reduction in local CSF velocities near nerve roots. CFD velocity profiles were relatively uniform around the spinal cord for all subjects. This study represents the first comparison of 4D PC MRI measurements to CFD of CSF flow in the cervical SSS. The results highlight the utility of 4D PC MRI for evaluation of complex CSF dynamics and the need for improvement of CFD methodology. Future studies are needed to investigate whether integration of fine anatomical structures and gross motion of the brain and/or spinal cord into the computational model will lead to a better agreement between the two techniques.
Objectives
To evaluate in-stent lumen visibility of 27 modern and commonly used coronary stents (16 individual stent types, two stents at six different sizes each) utilising a third-generation ...dual-source CT system.
Methods
Stents were implanted in a plastic tube filled with contrast. Examinations were performed parallel to the system's z-axis for all stents (i.e. 0°) and in an orientation of 90° for stents with a diameter of 3.0 mm. Two stents were evaluated in different diameters (2.25 to 4.0 mm). Examinations were acquired with a collimation of 96 × 0.6 mm, tube voltage of 120 kVp with 340 mAs tube current. Evaluation was performed using a medium-soft (Bv40), a medium-sharp (Bv49) and a sharp (Bv59) convolution kernel optimised for vascular imaging.
Results
Mean visible stent lumen of stents with 3.0 mm diameter ranged from 53.3 % (IQR 48.9 − 56.7 %) to 73.9 % (66.7 − 76.7 %), depending on the kernel used at 0°, and was highest at an orientation of 90° with 80.0 % (75.6 − 82.8 %) using the Bv59 kernel, strength 4. Visible stent lumen declined with decreasing stent size.
Conclusions
Use of third-generation dual-source CT enables stent lumen visibility of up to 80 % in metal stents and 100 % in bioresorbable stents.
Key Points
•
Blooming artefacts impair in–stent lumen visibility of coronary stents in CT angiography.
•
CT enables stent lumen visibility of up to 80 % in metal stents.
•
Stent lumen visibility varies with stent orientation and size.
•
CT angiography may be a valid alternative for detecting in-stent restenosis.