An accurate estimation of the risk of life-threatening (LT) ventricular tachyarrhythmia (VTA) in patients with LMNA mutations is crucial to select candidates for implantable ...cardioverter-defibrillator implantation.
We included 839 adult patients with LMNA mutations, including 660 from a French nationwide registry in the development sample, and 179 from other countries, referred to 5 tertiary centers for cardiomyopathies, in the validation sample. LTVTA was defined as (1) sudden cardiac death or (2) implantable cardioverter defibrillator-treated or hemodynamically unstable VTA. The prognostic model was derived using the Fine-Gray regression model. The net reclassification was compared with current clinical practice guidelines. The results are presented as means (SD) or medians interquartile range.
We included 444 patients, 40.6 (14.1) years of age, in the derivation sample and 145 patients, 38.2 (15.0) years, in the validation sample, of whom 86 (19.3%) and 34 (23.4%) experienced LTVTA over 3.6 1.0-7.2 and 5.1 2.0-9.3 years of follow-up, respectively. Predictors of LTVTA in the derivation sample were: male sex, nonmissense LMNA mutation, first degree and higher atrioventricular block, nonsustained ventricular tachycardia, and left ventricular ejection fraction (https://lmna-risk-vta.fr). In the derivation sample, C-index (95% CI) of the model was 0.776 (0.711-0.842), and the calibration slope 0.827. In the external validation sample, the C-index was 0.800 (0.642-0.959), and the calibration slope was 1.082 (95% CI, 0.643-1.522). A 5-year estimated risk threshold ≥7% predicted 96.2% of LTVTA and net reclassified 28.8% of patients with LTVTA in comparison with the guidelines-based approach.
In comparison with the current standard of care, this risk prediction model for LTVTA in laminopathies significantly facilitated the choice of candidates for implantable cardioverter defibrillators.
URL: https://www.clinicaltrials.gov. Unique identifier: NCT03058185.
Although such data are available for young competitive athletes, the prevalence, characteristics, and outcome of sports-related sudden death have not been assessed previously in the general ...population.
A prospective and comprehensive national survey was performed throughout France from 2005 to 2010, involving subjects 10 to 75 years of age. Case detection for sports-related sudden death, including resuscitated cardiac arrest, was undertaken via national ambulance service reporting and Web-based screening of media releases. The overall burden of sports-related sudden death was 4.6 cases per million population per year, with 6% of cases occurring in young competitive athletes. Sensitivity analyses used to address suspected underreporting demonstrated an incidence ranging from 5 to 17 new cases per million population per year. More than 90% of cases occurred in the context of recreational sports. The age of subjects was relatively young (mean ± SD 46 ± 15 years), with a predominance of men (95%). Although most cases were witnessed (93%), bystander cardiopulmonary resuscitation was only commenced in 30.7% of cases. Bystander cardiopulmonary resuscitation (odds ratio 3.73, 95% confidence interval 2.19 to 6.39, P<0.0001) and initial use of cardiac defibrillation (odds ratio 3.71, 95% confidence interval 2.07 to 6.64, P<0.0001) were the strongest independent predictors for survival to hospital discharge (15.7%, 95% confidence interval 13.2% to 18.2%).
Sports-related sudden death in the general population is considerably more common than previously suspected. Most cases are witnessed, yet bystander cardiopulmonary resuscitation was only initiated in one third of cases. Given the often predictable setting of sports-related sudden death and that prompt interventions were significantly associated with improved survival, these data have implications for health services planning.
Femoral access is the gold standard for transcatheter aortic valve replacement (TAVR). Guidelines recommend reconsidering surgery when this access is not feasible. However, alternative peripheral ...accesses exist, although they have not been accurately compared with femoral access.
This study compared nonfemoral peripheral (n-FP) TAVR with femoral TAVR.
Using the data from the national prospective French registry (FRANCE TAVI French Transcatheter Aortic Valve Implantation), this study compared the characteristics and outcomes of TAVR procedures according to whether they were performed through a femoral or a n-FP access, using a pre-specified propensity score−based matching between groups. Subanalysis during 2 study periods (2013 to 2015 and 2016 to 2017) and among low/intermediate-low and intermediate-high/high volume centers were performed.
Among 21,611 patients, 19,995 (92.5%) underwent femoral TAVR and 1,616 (7.5%) underwent n-FP TAVR (transcarotid, n = 914 or trans-subclavian, n = 702). Patients in the n-FP access group had more severe disease (mean logistic EuroSCORE 19.95 vs. 16.95; p < 0.001), with a higher rate of peripheral vascular disease, known coronary artery disease, chronic pulmonary disease, and renal failure. After matching, there was no difference in the rate of post-procedural death and complications according to access site, except for a 2-fold lower rate of major vascular complications (odds ratio: 0.45; 95% confidence interval: 0.21 to 0.93; p = 0.032) and unplanned vascular repairs (odds ratio: 0.41; 95% confidence interval: 0.29 to 0.59; p < 0.001) in those who underwent n-FP access. The comparison of outcomes provided similar results during the second study period and in intermediate-high/high volume centers.
n-FP TAVR is associated with similar outcomes compared with femoral peripheral TAVR, except for a 2-fold lower rate of major vascular complications and unplanned vascular repairs. n-FP TAVR may be favored over surgery in patients who are deemed ineligible for femoral TAVR and may be a safe alternative when femoral access risk is considered too high.
Display omitted
Abstract
It is unclear to what extent the COVID-19 pandemic has influenced the use of remote monitoring (RM) of cardiac implantable electronic devices (CIEDs). The present physician-based European ...Heart Rhythm Association (EHRA) survey aimed to assess the influence of the COVID-19 pandemic on RM of CIEDs among EHRA members and how it changed the current practice. The survey comprised 27 questions focusing on RM use before and during the pandemic. Questions focused on the impact of COVID-19 on the frequency of in-office visits, data filtering, reasons for initiating in-person visits, underutilization of RM during COVID-19, and RM reimbursement. A total of 160 participants from 28 countries completed the survey. Compared to the pre-pandemic period, there was a significant increase in the use of RM in patients with pacemakers (PMs) and implantable loop recorders (ILRs) during the COVID-19 pandemic (PM 24.2 vs. 39.9%, P = 0.002; ILRs 61.5 vs. 73.5%, P = 0.028), while there was a trend towards higher utilization of RM for cardiac resynchronization therapy-pacemaker (CRT-P) devices during the pandemic (44.5 vs. 55%, P = 0.063). The use of RM with implantable cardioverter-defibrillators (ICDs) and CRT-defibrillator (CRT-D) did not significantly change during the pandemic (ICD 65.2 vs. 69.6%, P = 0.408; CRT-D 65.2 vs. 68.8%, P = 0.513). The frequency of in-office visits was significantly lower during the pandemic (P < 0.001). Nearly two-thirds of participants (57 out of 87 respondents), established new RM connections for CIEDs implanted before the pandemic with 33.3% (n = 29) delivering RM transmitters to the patient’s home address, and the remaining 32.1% (n = 28) activating RM connections during an in-office visit. The results of this survey suggest that the crisis caused by COVID-19 has led to a significant increase in the use of RM of CIEDs.
Abstract
Aims
Recent studies have shown that in more than half of apparently unexplained sudden cardiac arrests (SCA), a specific aetiology can be unmasked by a careful evaluation. The ...characteristics and the extent to which such cases undergo a systematic thorough investigation in real-life practice are unknown.
Methods and results
Data were analysed from an ongoing study, collecting all cases of out-of-hospital cardiac arrest in Paris area. Investigations performed during the index hospitalization or planned after discharge were gathered to evaluate the completeness of assessment of unexplained SCA. Between 2011 and 2016, among the 18 622 out-of-hospital cardiac arrests, 717 survivors (at hospital discharge) fulfilled the definition of cardiac SCA. Of those, 88 (12.3%) remained unexplained after electrocardiogram, echocardiography, and coronary angiography. Cardiac magnetic resonance imaging yielded the diagnosis in 25 (3.5%) cases, other investigations accounted for 14 (2.4%) additional diagnoses, and 49 (6.8%) patients were labelled as idiopathic ventricular fibrillation (IVF) (48.7 ± 15 years, 69.4% male). Among those labelled IVF, only 8 (16.3%) cases benefited from a complete workup (including pharmacological testing). Younger patients odds ratio (OR) 6.00, 95% confidence interval (CI) 1.80–22.26 and those admitted to university centres (OR 3.60, 95% CI 1.12–12.45) were more thoroughly investigated. Genetic testing and family screening were initiated in only 9 (18.4%) and 12 (24.5%) cases, respectively.
Conclusion
Our findings suggest that complete investigations are carried out in a very low proportion of unexplained SCA. Standardized, systematic approaches need to be implemented to ensure that opportunities for specific therapies and preventive strategies (including relatives) are not missed.
Real‐Time Contact Force Sensing for Pulmonary Vein Isolation
Introduction
The additional benefit of contact force (CF) technology during pulmonary vein isolation (PVI) for paroxysmal atrial ...fibrillation (AF) to improve mid‐term clinical outcome is unclear.
Methods and Results
Eligible patients with symptomatic paroxysmal AF were enrolled in this prospective trial, comparing circular antral catheter ablation (guided by Carto 3 System, Biosense Webster) using either a new open‐irrigated CF catheter (SmartTouch Thermocool, Biosense Webster) (CF group) or a non‐CF open‐irrigated catheter (EZ Steer Thermocool, Biosense Webster) (control group). Overall, 30 patients were enrolled in each group, with a standardized 12‐month follow‐up, free of antiarrhythmic therapy. Demographic, cardiovascular and anatomic characteristics were similar in both groups. Though complete PVI was eventually achieved in all cases in both groups, success using an exclusive anatomic approach was 80.0% in CF group versus 36.7% in control group (P < 0.0001). CF use was associated with significant reductions in fluoroscopy exposure (P < 0.01) and radiofrequency time (P = 0.01). The incidence rates of AF recurrence were 10.5% (95% CI, 1.38–22.4) in the CF group, and 35.9% (95% CI, 12.4–59.4) in the control group (log rank test, P = 0.04). After adjustment on potential confounders, the use of CF catheter was found to be associated with a lower AF recurrence (OR 0.18, 95% CI 0.04–0.94, P = 0.04).
Conclusion
Our findings suggest a potential benefit of real‐time CF sensing technology, in reducing AF recurrence during the first year after PVI.
In children with structurally normal hearts, the mechanisms of arrhythmias are usually the same as in the adult patient. Some arrhythmias are particularly associated with young age and very rarely ...seen in adult patients. Arrhythmias in structural heart disease may be associated either with the underlying abnormality or result from surgical intervention. Chronic haemodynamic stress of congenital heart disease (CHD) might create an electrophysiological and anatomic substrate highly favourable for re-entrant arrhythmias. As a general rule, prescription of antiarrhythmic drugs requires a clear diagnosis with electrocardiographic documentation of a given arrhythmia. Risk-benefit analysis of drug therapy should be considered when facing an arrhythmia in a child. Prophylactic antiarrhythmic drug therapy is given only to protect the child from recurrent supraventricular tachycardia during this time span until the disease will eventually cease spontaneously. In the last decades, radiofrequency catheter ablation is progressively used as curative therapy for tachyarrhythmias in children and patients with or without CHD. Even in young children, procedures can be performed with high success rates and low complication rates as shown by several retrospective and prospective paediatric multi-centre studies. Three-dimensional mapping and non-fluoroscopic navigation techniques and enhanced catheter technology have further improved safety and efficacy even in CHD patients with complex arrhythmias. During last decades, cardiac devices (pacemakers and implantable cardiac defibrillator) have developed rapidly. The pacing generator size has diminished and the pacing leads have become progressively thinner. These developments have made application of cardiac pacing in children easier although no dedicated paediatric pacing systems exist.
The indigenous populations of the South Pacific experience a high burden of rheumatic heart disease (RHD). Here we report a genome-wide association study (GWAS) of RHD susceptibility in 2,852 ...individuals recruited in eight Oceanian countries. Stratifying by ancestry, we analysed genotyped and imputed variants in Melanesians (607 cases and 1,229 controls) before follow-up of suggestive loci in three further ancestral groups: Polynesians, South Asians and Mixed or other populations (totalling 399 cases and 617 controls). We identify a novel susceptibility signal in the immunoglobulin heavy chain (IGH) locus centring on a haplotype of nonsynonymous variants in the IGHV4-61 gene segment corresponding to the IGHV4-61*02 allele. We show each copy of IGHV4-61*02 is associated with a 1.4-fold increase in the risk of RHD (odds ratio 1.43, 95% confidence intervals 1.27-1.61, P=4.1 × 10
). These findings provide new insight into the role of germline variation in the IGH locus in disease susceptibility.