A short description of the muon tomography demonstrator at the INFN Laboratori Nazionali di Legnaro near Padua, Italy, is given and the principal achievements owing to the data collected at that ...experimental facility are presented. In particular, the feasibility studies for several applications based on the muon-tomographic technology, within national and European projects, are discussed. The experimental problems and the procedures used to improve the performance are underlined. In addition, new activities and the related detector optimization are illustrated.This article is part of the Theo Murphy meeting issue 'Cosmic-ray muography'.
Performance of a proton irradiation chamber Agosteo, S.; Borsato, E.; Dal Corso, F. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
02/2012, Letnik:
664, Številka:
1
Journal Article
Recenzirano
Odprti dostop
A Proton Irradiation Chamber aiming to perform radiation tests of electronic components was developed. The precision on the measurement of the ion currents was pushed beyond the resolution of the ...picoammeter by means of a series of collimators on the beam showing a linear correlation among the currents measured on them and the smaller, not measurable, current on the target. As an example of the obtained results the tests done on a Si microdosimeter and a power p-MOS are reported.
INFN muon tomography demonstrator Checchia, P.; Benettoni, M.; Bettella, G. ...
Philosophical transactions of the Royal Society of London. Series A: Mathematical, physical, and engineering sciences,
01/2019, Letnik:
377, Številka:
2137
Journal Article
Recenzirano
A short description of the muon tomography demonstrator at the INFN Laboratori Nazionali di Legnaro near Padua, Italy, is given and the principal achievements owing to the data collected at that ...experimental facility are presented. In particular, the feasibility studies for several applications based on the muon-tomographic technology, within national and European projects, are discussed. The experimental problems and the procedures used to improve the performance are underlined. In addition, new activities and the related detector optimization are illustrated.
This article is part of the Theo Murphy meeting issue ‘Cosmic-ray muography’.
This document presents an overview of the induced photocurrents in the Amorphous Silicon Position Detectors used in the network of diode lasers and photo sensors of the CMS Link alignment system ...recorded during its eleven years of operation. After a description of the sensors characteristics, the layout of the sensors network is discussed. The sensors are distributed throughout the muon spectrometer and connected by laser lines. The data used correspond to readout information obtained during some of the physics runs from 2008 to 2018.
The central feature of the CMS Link alignment system is a network of Amorphous Silicon Position Detectors distributed throughout the muon spectrometer that are connected by multiple laser lines. The ...data collected during the years from 2008 to 2015 is presented confirming an outstanding performance of the photo sensors during more than seven years of operation. Details of the photo sensor readout of the laser signals are presented. The mechanical motions of the CMS detector are monitored using these photosensors and good agreement with distance sensors is obtained.
Magnet Cycles and Stability Periods of the CMS Experiment are studied with the Alignment Link System data recorded along the 2008–2013 years of operation. The motions of the mechanical structures due ...to the magnetic field forces are studied and the mechanical stability of the detector during the physics data taking periods is verified.
A study of the time required for the CMS detector to reach structural equilibrium once the magnetic field is ramped to its operational value of 3.8T is presented. In addition, the results from a ...stability monitoring at 3.8T over an eight-month period are given.