KAMEO (Kaonic Atoms Measuring Nuclear Resonance Effects Ob-servables) is a proposal for an experiment aiming to perform the first consistent measurement of the E2 nuclear resonance effects in kaonic ...molybdenum A=94,96,98,100 isotopes. The E2 nuclear resonance mixes atomic states, due to the electrical quadrupole excitation of nuclear rotational states. It occurs in atoms having the energy of a nuclear excitation state closely matching an atomic de-excitation state energy, and affects the rates of X-ray atomic transitions matching the energy of the resonance. The measurement E2 nuclear resonance effect in KMO isotopes allows the study of the strong kaon-nucleus interaction in a rotational excited nuclear state. Moreover, the effect enables the K - to access an inner atomic level not easily reachable by the kaon normal cascade, due to the nuclear absorption. The KAMEO proposed apparatus consists of 4 enriched Mo A=94,96,98,100 isotope strips, exposed to the kaons produced by the DAφNE collider, for kaonic atoms formation, with a high-purity germanium detector, cooled with liquid nitrogen, used to measure the X-ray atomic transitions. The DAφNE collider is located at the National Laboratories of Frascati (LNF-INFN), in Italy. It is already suited for kaonic atoms measurement by the SIDDHARTA-2 collaboration.
The most important information still missing in the field of the low-energy antikaon-nucleon inter actions studies is the experimental determination of the hadronic energy shift and width of kaonic ...deuterium. This measurement will be performed by the SIDDHARTA-2 experiment, installed at the DAΦNE collider and presently in data taking campaign. The precise measurement of the shift and width of the 1s level with respect to the purely electromagnetic calculated values, generated by the presence of the strong interaction, through the measurement of the X-ray transitions to this level, in kaonic hydrogen, was performed by the SIDDHARTA collaboration, the kaonic deuterium is underway by SIDDHARTA-2. These measurement will allow the first precise experimental extraction of the isospin dependent antikaon-nucleon scattering lengths, funda mental quantities for understanding low-energy QCD in the strangeness sector. The experimental challenge of the kaonic deuterium measurement is the very small X-rays yield, the even larger width (compared to kaonic hy drogen), and the difficulty to perform X-rays spectroscopy with weak signals in the high radiation environment of DAΦNE. It was, therefore, crucial to develop a new apparatus involving large-area X-rays detector system, to optimize the signal and to control and by improve the signal-to-background ratio by gaining in solid angle, increasing the timing capability, and as well implementing additional charge particle tracking veto systems.
Background
The Jagiellonian Positron Emission Tomograph is the 3-layer prototype of the first scanner based on plastic scintillators, consisting of 192 half-metre-long strips with readouts at both ...ends. Compared to crystal-based detectors, plastic scintillators are several times cheaper and could be considered as a more economical alternative to crystal scintillators in future PETs. JPET is also a first multi-photon PET prototype. For the development of multi-photon detection, with photon characterized by the continuous energy spectrum, it is important to estimate the efficiency of J-PET as a function of energy deposition. The aim of this work is to determine the registration efficiency of the J-PET tomograph as a function of energy deposition by incident photons and the intrinsic efficiency of the J-PET scanner in detecting photons of different incident energies. In this study, 3-hit events are investigated, where 2-hits are caused by 511 keV photons emitted in
e
+
e
-
annihilations, while the third hit is caused by one of the scattered photons. The scattered photon is used to accurately measure the scattering angle and thus the energy deposition. Two hits by a primary and a scattered photon are sufficient to calculate the scattering angle of a photon, while the third hit ensures the precise labeling of the 511 keV photons.
Results
By comparing experimental and simulated energy distribution spectra, the registration efficiency of the J-PET scanner was determined in the energy deposition range of 70–270 keV, where it varies between 20 and 100
%
. In addition, the intrinsic efficiency of the J-PET was also determined as a function of the energy of the incident photons.
Conclusion
A method for determining registration efficiency as a function of energy deposition and intrinsic efficiency as a function of incident photon energy of the J-PET scanner was demonstrated. This study is crucial for evaluating the performance of the scanner based on plastic scintillators and its applications as a standard and multi-photon PET systems. The method may be also used in the calibration of Compton-cameras developed for the ion−beam therapy monitoring and simultaneous multi-radionuclide imaging in nuclear medicine.
Research conducted in the framework of the Jagiellonian-PET (J-PET) project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a ...full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, which have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required the development of new calibration methods including time, thresholds, and gain synchronization. The system and elaborated calibration methods, including first results of the 24-module J-PET prototype, are presented and discussed. The achieved coincidence resolving time equals to <inline-formula> <tex-math notation="LaTeX">{\mathrm {CRT}}=490\pm 9 </tex-math></inline-formula> ps. This value can be translated to the position reconstruction accuracy <inline-formula> <tex-math notation="LaTeX">\sigma (\Delta l) =18 </tex-math></inline-formula> mm, which is fairly position independent.
We present the tests performed by the SIDDHARTA-2 collaboration at the
DA
Φ
NE
collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in ...a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy mass kaonic atoms. The CdZnTe detector was installed for the first time in an accelerator environment to perform tests on the background rejection capabilities, which were achieved by exploiting the SIDDHARTA-2 Luminosity Monitor. A spectrum with an
241
Am
source has been acquired, with beams circulating in the main rings, and peak resolutions of 6% at 60 keV and of 2.2% at 511 keV have been achieved. The background suppression factor, which turned out to be of the order of
≃
10
5
-
6
, opens the possibility to plan for future kaonic atom measurements with CdZnTe detectors.
The E2 nuclear resonance effect in kaonic atoms occurs when the energy of atomic de-excitation closely matches the energy of nuclear excitation, leading to the attenuation of some X-ray lines in the ...resonant isotope target. This phenomenon provides crucial information on the strong interaction between kaons and nuclei. The only nuclear E2 resonance effect observed so far was in the K
−
−
98
42
Mo isotope, measured by G. L. Goldfrey, G-K. Lum, and C. E. Wiegand at Lawrence Berkeley Laboratory in 1975. However, the 25 hours of data taking were not sufficient to yield conclusive results. In four kaonic Molybdenum isotopes (
94
42
Mo,
96
42
Mo,
98
42
and Mo, and
100
42
Mo), the nuclear E2 resonance effect is expected to occur at the same transition with similar energy values. To investigate this, the KAMEO (Kaonic Atoms Measuring Nuclear Resonance Effects Observables) experiment plans to conduct research on kaonic Molybdenum isotopes at the DAΦNE e
+
e
−
collider during the SIDDHARTA-2 experiment. The experimental strategy involves exposing four solid strip targets, each enriched with one Molybdenum isotope, to negatively charged kaons and using a germanium detector to measure X-ray transitions. In addition, a non-resonant
92
42
Mo isotope solid strip target will be used as a reference for standard non-resonant transitions.
Light kaonic atoms spectroscopy provides a unique approach to study the low-energy strong interaction in the strangeness sector. Precise measurements of X-ray emission from light kaonic atoms provide ...valuable information on kaon-nucleus interaction at threshold without the need for extrapolation as required in scattering experiments. The SIDDHARTA-2 experiment at the DAΦNE collider of INFN-LNF is now poised to perform the challenging measurements of the K
−
- d 2p → 1s transition to extract the isospin-dependent antikaonnucleon scattering lengths. To achieve this goal, the background reduction is a crucial factor. This paper provides an overview of the SIDDHARTA-2 Veto-1 system, which uses scintillators outside the vacuum chamber to detect charged particles produced by K− absorption by the nucleus. The arrival time of these particles is correlated with the position where the kaonic atom has been created inside the setup, allowing for the rejection of kaons stopped outside the target cell, which is a critical component for reducing the background and improve the accuracy of the measurement.
Kaonic atoms measurements with SIDDHARTA-2 Sgaramella, F.; Bazzi, M.; Bosnar, D. ...
Journal of physics. Conference series,
02/2023, Letnik:
2446, Številka:
1
Journal Article
Recenzirano
Odprti dostop
Abstract
The SIDDHARTA-2 collaboration is aiming to perform the challenging measurement of kaonic deuterium X-ray transitions to the ground state. This will allow to extract the isospin-dependent ...antikaon-nucleon scattering lengths, providing input to the theory of Quantum Chromodynamics (QCD) in the non-perturbative regime with strangeness. This work describes the SIDDHARTA-2 experimental apparatus and presents the results obtained during the commissioning phase realized with kaonic helium measurements. In particular, the first observation of the kaonic helium transitions to the 3s level (M-lines), reported in this work, represents a new source of information to study the kaonic helium cascade process and demonstrates the potential of the SIDDHARTA-2 apparatus, in the view of the ambitious kaonic deuterium measurement.