A brain-computer interface (BCI) is a communication system that allows the use of brain activity to control computers or other external devices. It can, by bypassing the peripheral nervous system, ...provide a means of communication for people suffering from severe motor disabilities or in a persistent vegetative state. In this paper, brain-signal generation tasks, noise removal methods, feature extraction/selection schemes, and classification techniques for fNIRS-based BCI are reviewed. The most common brain areas for fNIRS BCI are the primary motor cortex and the prefrontal cortex. In relation to the motor cortex, motor imagery tasks were preferred to motor execution tasks since possible proprioceptive feedback could be avoided. In relation to the prefrontal cortex, fNIRS showed a significant advantage due to no hair in detecting the cognitive tasks like mental arithmetic, music imagery, emotion induction, etc. In removing physiological noise in fNIRS data, band-pass filtering was mostly used. However, more advanced techniques like adaptive filtering, independent component analysis (ICA), multi optodes arrangement, etc. are being pursued to overcome the problem that a band-pass filter cannot be used when both brain and physiological signals occur within a close band. In extracting features related to the desired brain signal, the mean, variance, peak value, slope, skewness, and kurtosis of the noised-removed hemodynamic response were used. For classification, the linear discriminant analysis method provided simple but good performance among others: support vector machine (SVM), hidden Markov model (HMM), artificial neural network, etc. fNIRS will be more widely used to monitor the occurrence of neuro-plasticity after neuro-rehabilitation and neuro-stimulation. Technical breakthroughs in the future are expected via bundled-type probes, hybrid EEG-fNIRS BCI, and through the detection of initial dips.
•Classification of fNIRS signals corresponding to the right- and left-wrist motor imagery.•Hemodynamic responses of the right-wrist imagery are distinguishable from those of left.•Signal slope ...improves the classification accuracy significantly than signal mean.•Enhanced performance on examination of subset of the response data.
This paper presents a study on functional near-infrared spectroscopy (fNIRS) indicating that the hemodynamic responses of the right- and left-wrist motor imageries have distinct patterns that can be classified using a linear classifier for the purpose of developing a brain–computer interface (BCI). Ten healthy participants were instructed to imagine kinesthetically the right- or left-wrist flexion indicated on a computer screen. Signals from the right and left primary motor cortices were acquired simultaneously using a multi-channel continuous-wave fNIRS system. Using two distinct features (the mean and the slope of change in the oxygenated hemoglobin concentration), the linear discriminant analysis classifier was used to classify the right- and left-wrist motor imageries resulting in average classification accuracies of 73.35% and 83.0%, respectively, during the 10s task period. Moreover, when the analysis time was confined to the 2–7s span within the overall 10s task period, the average classification accuracies were improved to 77.56% and 87.28%, respectively. These results demonstrate the feasibility of an fNIRS-based BCI and the enhanced performance of the classifier by removing the initial 2s span and/or the time span after the peak value.
In this paper, a functional near-infrared spectroscopy (fNIRS)-based online binary decision decoding framework is developed. Fourteen healthy subjects are asked to mentally make “yes” or “no” ...decisions in answers to the given questions. For obtaining “yes” decoding, the subjects are asked to perform a mental task that causes a cognitive load on the prefrontal cortex, while for making “no” decoding, they are asked to relax. Signals from the prefrontal cortex are collected using continuous-wave near-infrared spectroscopy. It is observed and verified, using the linear discriminant analysis (LDA) and the support vector machine (SVM) classifications, that the cortical hemodynamic responses for making a “yes” decision are distinguishable from those for making a “no” decision. Using mean values of the changes in the concentration of hemoglobin as features, binary decisions are classified into two classes, “yes” and “no,” with an average classification accuracy of 74.28 % using LDA and 82.14 % using SVM. These results demonstrate and suggest the feasibility of fNIRS for a brain–computer interface.
•Feasibility of three-class fNIRS–BCI demonstrated.•Classification of fNIRS signals corresponding to three different brain activities.•Motor and prefrontal cortex activities ...used.•Intentionally-generated cognitive tasks as inputs.
Functional near-infrared spectroscopy (fNIRS) is an optical imaging method that can be used for a brain-computer interface (BCI). In the present study, we concurrently measure and discriminate fNIRS signals evoked by three different mental activities, that is, mental arithmetic (MA), right-hand motor imagery (RI), and left-hand motor imagery (LI). Ten healthy subjects were asked to perform the MA, RI, and LI during a 10s task period. Using a continuous-wave NIRS system, signals were acquired concurrently from the prefrontal and the primary motor cortices. Multiclass linear discriminant analysis was utilized to classify MA vs. RI vs. LI with an average classification accuracy of 75.6% across the ten subjects, for a 2–7s time window during the a 10s task period. These results demonstrate the feasibility of implementing a three-class fNIRS-BCI using three different intentionally-generated cognitive tasks as inputs.
In this paper, we present a systematic method to reduce the time lag in detecting initial dips using a vector-based phase diagram and an autoregressive moving average with exogenous signals (ARMAX) ...model-based q-step-ahead prediction algorithm. With functional near-infrared spectroscopy (fNIRS), signals related to mental arithmetic and right-hand clenching are acquired from the prefrontal and left primary motor cortices, respectively. The interrelationship between oxygenated hemoglobin, deoxygenated hemoglobin, total hemoglobin and cerebral oxygen exchange are related to initial dips. Specifically, a threshold value from the resting state hemodynamics is incorporated, as a decision criterion, into the vector-based phase diagram to determine the occurrence of initial dips. To further reduce the time lag, a Formula: see text-step-ahead prediction method is applied to predict the occurrence of the dips. A combination of the threshold criterion and the prediction method resulted in the delay time of about 0.9Formula: see texts. The results demonstrate that rapid detection of initial dip is possible and therefore can be used for real-time brain-computer interfacing.
With the astounding ability to capture a wealth of brain signals, Brain-Computer Interfaces (BCIs) have the potential to revolutionize humans' quality of life ....
Brain-computer interface (BCI) systems include signal acquisition, preprocessing, feature extraction, classification, and an application phase. In fNIRS-BCI systems, deep learning (DL) algorithms ...play a crucial role in enhancing accuracy. Unlike traditional machine learning (ML) classifiers, DL algorithms eliminate the need for manual feature extraction. DL neural networks automatically extract hidden patterns/features within a dataset to classify the data. In this study, a hand-gripping (closing and opening) two-class motor activity dataset from twenty healthy participants is acquired, and an integrated contextual gate network (ICGN) algorithm (proposed) is applied to that dataset to enhance the classification accuracy. The proposed algorithm extracts the features from the filtered data and generates the patterns based on the information from the previous cells within the network. Accordingly, classification is performed based on the similar generated patterns within the dataset. The accuracy of the proposed algorithm is compared with the long short-term memory (LSTM) and bidirectional long short-term memory (Bi-LSTM). The proposed ICGN algorithm yielded a classification accuracy of 91.23 ± 1.60%, which is significantly (
< 0.025) higher than the 84.89 ± 3.91 and 88.82 ± 1.96 achieved by LSTM and Bi-LSTM, respectively. An open access, three-class (right- and left-hand finger tapping and dominant foot tapping) dataset of 30 subjects is used to validate the proposed algorithm. The results show that ICGN can be efficiently used for the classification of two- and three-class problems in fNIRS-based BCI applications.
Human gait is a complex activity that requires high coordination between the central nervous system, the limb, and the musculoskeletal system. More research is needed to understand the latter ...coordination's complexity in designing better and more effective rehabilitation strategies for gait disorders. Electroencephalogram (EEG) and functional near-infrared spectroscopy (fNIRS) are among the most used technologies for monitoring brain activities due to portability, non-invasiveness, and relatively low cost compared to others. Fusing EEG and fNIRS is a well-known and established methodology proven to enhance brain-computer interface (BCI) performance in terms of classification accuracy, number of control commands, and response time. Although there has been significant research exploring hybrid BCI (hBCI) involving both EEG and fNIRS for different types of tasks and human activities, human gait remains still underinvestigated. In this article, we aim to shed light on the recent development in the analysis of human gait using a hybrid EEG-fNIRS-based BCI system. The current review has followed guidelines of preferred reporting items for systematic reviews and meta-Analyses (PRISMA) during the data collection and selection phase. In this review, we put a particular focus on the commonly used signal processing and machine learning algorithms, as well as survey the potential applications of gait analysis. We distill some of the critical findings of this survey as follows. First, hardware specifications and experimental paradigms should be carefully considered because of their direct impact on the quality of gait assessment. Second, since both modalities, EEG and fNIRS, are sensitive to motion artifacts, instrumental, and physiological noises, there is a quest for more robust and sophisticated signal processing algorithms. Third, hybrid temporal and spatial features, obtained by virtue of fusing EEG and fNIRS and associated with cortical activation, can help better identify the correlation between brain activation and gait. In conclusion, hBCI (EEG + fNIRS) system is not yet much explored for the lower limb due to its complexity compared to the higher limb. Existing BCI systems for gait monitoring tend to only focus on one modality. We foresee a vast potential in adopting hBCI in gait analysis. Imminent technical breakthroughs are expected using hybrid EEG-fNIRS-based BCI for gait to control assistive devices and Monitor neuro-plasticity in neuro-rehabilitation. However, although those hybrid systems perform well in a controlled experimental environment when it comes to adopting them as a certified medical device in real-life clinical applications, there is still a long way to go.
In this study, we determine the optimal feature-combination for classification of functional near-infrared spectroscopy (fNIRS) signals with the best accuracies for development of a two-class ...brain-computer interface (BCI). Using a multi-channel continuous-wave imaging system, mental arithmetic signals are acquired from the prefrontal cortex of seven healthy subjects. After removing physiological noises, six oxygenated and deoxygenated hemoglobin (HbO and HbR) features-mean, slope, variance, peak, skewness and kurtosis-are calculated. All possible 2- and 3-feature combinations of the calculated features are then used to classify mental arithmetic vs. rest using linear discriminant analysis (LDA). It is found that the combinations containing mean and peak values yielded significantly higher (p < 0.05) classification accuracies for both HbO and HbR than did all of the other combinations, across all of the subjects. These results demonstrate the feasibility of achieving high classification accuracies using mean and peak values of HbO and HbR as features for classification of mental arithmetic vs. rest for a two-class BCI.
This research presents a brain-computer interface (BCI) framework for brain signal classification using deep learning (DL) and machine learning (ML) approaches on functional near-infrared ...spectroscopy (fNIRS) signals. fNIRS signals of motor execution for walking and rest tasks are acquired from the primary motor cortex in the brain's left hemisphere for nine subjects. DL algorithms, including convolutional neural networks (CNNs), long short-term memory (LSTM), and bidirectional LSTM (Bi-LSTM) are used to achieve average classification accuracies of 88.50%, 84.24%, and 85.13%, respectively. For comparison purposes, three conventional ML algorithms, support vector machine (SVM), k-nearest neighbor (k-NN), and linear discriminant analysis (LDA) are also used for classification, resulting in average classification accuracies of 73.91%, 74.24%, and 65.85%, respectively. This study successfully demonstrates that the enhanced performance of fNIRS-BCI can be achieved in terms of classification accuracy using DL approaches compared to conventional ML approaches. Furthermore, the control commands generated by these classifiers can be used to initiate and stop the gait cycle of the lower limb exoskeleton for gait rehabilitation.