The spatial resolution along the pad-row direction was measured with a GEM-based TPC prototype for the future linear collider experiment in order to understand its performance for tracks with finite ...projected angles with respect to the pad-row normal. The degradation of the resolution due to the angular pad effect was confirmed to be consistent with the prediction of a simple calculation taking into account the cluster-size distribution and the avalanche fluctuation.
A time projection chamber (TPC) is a strong candidate for the central tracker of the international linear collider (ILC) experiment and we have been conducting a series of cosmic ray experiments ...under a magnetic field up to 4T, using a small prototype TPC with a replaceable readout device: multi-wire proportional chamber (MWPC) or gas electron multiplier (GEM). We first confirmed that the MWPC readout could not be a fall-back option of the ILC-TPC under a strong axial magnetic field of 4T since its spatial resolution suffered severely from the so called E×B effect in the vicinity of the wire planes. The GEM readout, on the other hand, was found to be virtually free from the E×B effect and gave the resolution determined by the transverse diffusion of the drift electrons (diffusion limited). Furthermore, GEMs allow a wider choice of gas mixtures than MWPCs. Among the gases we tried so far a mixture of Ar–CF4-isobutane seems promising as the operating gas of the ILC-TPC because of its small diffusion constant especially under a strong magnetic field. We report the spatial resolution obtained with the GEM readout in this gas mixture. Also presented is the spatial resolution of a GEM-based ILC-TPC estimated from the measurement with the prototype.
We present a search for lepton-flavor-violating τ decays into three leptons (electrons or muons) using 782 fb−1 of data collected with the Belle detector at the KEKB asymmetric-energy e+e− collider. ...No evidence for these decays is observed and we set 90% confidence level upper limits on the branching fractions between 1.5×10−8 and 2.7×10−8.
We conducted a series of beam tests of prototype TPCs for the International Linear Collider (ILC) experiment, equipped with an MWPC, a MicroMEGAS, or GEMs as a readout device. The prototype operated ...successfully in a test beam at KEK under an axial magnetic field of up to 1
T. The analysis of data is now in progress and some of the preliminary results obtained with GEMs and MicroMEGAS are presented along with our interpretation. Also given is the extrapolation of the obtained spatial resolution to that of a large TPC expected as the central tracker of the ILC experiment.
We search for lepton-flavor and lepton-number-violating τ decays into a lepton (ℓ= electron or muon) and two charged mesons (h,h′=π± or K±) using 854 fb−1 of data collected with the Belle detector at ...the KEKB asymmetric-energy e+e− collider. We obtain 90% confidence level upper limits on the τ→ℓhh′ branching fractions in the range (2.0–8.4)×10−8. These results improve upon our previously published upper limits by factors of about 1.8 on average.