Incomplete stent apposition (ISA) is characterized by the lack of contact of at least 1 stent strut with the vessel wall in a segment not overlying a side branch; it is more commonly found in ...drug-eluting stents than bare-metal stents. The accurate diagnosis of ISA, initially only possible with intravascular ultrasound, can currently be performed with higher accuracy by optical coherence tomography, which also enables strut-level assessment due to its higher axial resolution. Different circumstances related both to the index procedure and to vascular healing might influence ISA occurrence. Although several histopathology and clinical studies linked ISA to stent thrombosis, potential selection bias precluded definitive conclusions. Initial studies usually performed single time point assessments comparing overall ISA percentage and magnitude in different groups (i.e., stent type), thus hampering a comprehensive understanding of its relationship with vascular healing. Serial intravascular imaging studies that evaluated vascular response heterogeneity recently helped fill this gap. Some particular clinical scenarios such as acute coronary syndromes, bifurcations, tapered vessels, overlapping stents, and chronic total occlusions might predispose to ISA. Interventional cardiologists should be committed to optimal stent choices and techniques of implantation and use intravascular imaging guidance when appropriate to aim at minimizing acute ISA. In addition, the active search for new stent platforms that could accommodate vessel remodeling over time (i.e., self-expandable stents) and for new polymers and/or eluting drugs that could induce less inflammation (hence, less positive remodeling) could ultimately reduce the occurrence of ISA and its potentially harmful consequences.
Abstract Objectives The purpose of this analysis was to assess 5-year outcomes of transcatheter aortic valve implantation (TAVI) using the current technology of the self-expanding CoreValve ...prosthesis (Medtronic Inc., Minneapolis, Minnesota). Background There is a paucity of evidence on long-term durability of currently available transcatheter heart valves. Methods Starting in June 2007, all consecutive patients with severe aortic stenosis undergoing TAVI with the third-generation 18-F CoreValve device in 8 Italian centers were prospectively included in the ClinicalService Project. For the purposes of this study, we included only consecutive patients with 5-year follow-up data available (n = 353) treated from June 2007 to August 2009. All outcomes were reported according to VARC (Valve Academic Research Consortium)-1 criteria. Results All-cause mortality rates at 1, 2, 3, 4, and 5 years were 21%, 29%, 38%, 48%, and 55.0%, respectively. Cardiovascular mortality rates at 1, 2, 3, 4, and 5 years were 10%, 14%, 19%, 23%, and 28.0%, respectively. The overall neurological event rate at 5 years was 7.5%, of which more than two-thirds occurred early after the procedure. During follow-up, there were 241 rehospitalizations for cardiovascular reasons in 164 (46%) patients. Among all rehospitalizations, acute heart failure was the most frequently reported (42.7%), followed by requirement of permanent pacemaker implantation (17.4%). On echocardiography, mean transaortic gradients decreased from 55.6 ± 16.8 mm Hg (pre-TAVI) to 12.8 ± 10.9 mm Hg (5-year post-TAVI) (p < 0.001). Late prosthesis failure occurred in 5 cases (1.4%); among these, redo TAVI was successfully carried out in 2 patients (0.6%) presenting with symptomatic prosthesis restenosis. The remaining 3 cases of prosthesis failure did not undergo further invasive interventions. Ten patients (2.8%) showed late mild stenosis with a mean transaortic gradient ranging from 20 to 40 mm Hg. No other cases of structural or nonstructural valvular deterioration were observed. Valve thrombosis or late valve embolization were not reported. Conclusions TAVI with the currently adopted CoreValve generation was associated with sustained clinical outcomes up to 5-year follow-up, with a low rate (1.4%) of significant prosthetic valve degeneration. The procedure appears to be an adequate and lasting resolution of aortic stenosis in selected high-risk patients.
Objectives This study sought to evaluate the association between contrast-induced acute kidney injury (CI-AKI) after percutaneous coronary intervention and severity of bleeding estimated from ...periprocedural hemoglobin (Hb) measurement. Background The relationship between CI-AKI and bleeding in contemporary practice remains controversial. Methods In a retrospective analysis of the prospectively maintained Japan Cardiovascular Database-Keio Interhospital Cardiovascular Studies (JCD-KICS) multicenter registry, we divided 2,646 consecutive patients into 5 groups according to the change of Hb level after compared with before percutaneous coronary intervention: patients without a decrease in Hb level (group A) and patients with a decreased Hb level: <1 g/dl (group B); 1 to <2 g/dl (group C); 2 to <3g/dl (group D); and >3 g/dl (group E). CI-AKI was defined as an increase in serum creatinine level ≥0.5 mg/dl or ≥25% above baseline values at 48 h after administration of contrast media. Procedure and outcome variables were compared. Results The mean patient age was 67 ± 11 years. Of the 2,646 patients, CI-AKI developed in 315 (11.9%). The CI-AKI incidence was 6.2%, 7.5%, 10.7%, 17.0%, and 26.2%, in groups A through E, respectively (p < 0.01), whereas the incidence of major bleeding was 0.7%, 1.3%, 2.0%, 4.1%, and 28.3%, respectively (p < 0.01). CI-AKI was associated with higher rates of mortality (5.4% vs. 0.6%, p < 0.01) and of composite of heart failure, cardiogenic shock, and death (16.5% vs. 2.8%, p < 0.01). Conclusions Periprocedural bleeding was significantly associated with CI-AKI, with CI-AKI incidence correlating with bleeding severity.
The current transcatheter aortic valve implantation (TAVI) devices have been designed to fit Caucasian and Latin American aortic root anatomies. We evaluated the racial differences in aortic root ...anatomy and calcium distribution in patients with aortic stenosis who underwent TAVI. We conducted a multicenter study of 4 centers in Asia and Europe, which includes consecutive patients who underwent TAVI with preprocedural multidetector computed tomography. Quantitative assessment of aortic root dimensions, calcium volume for leaflet, and left ventricular outflow tract were retrospectively performed in a centralized core laboratory. A total of 308 patients (Asian group, n = 202; Caucasian group, n = 106) were analyzed. Compared to Caucasian group, Asian group had smaller annulus area (406.3 ± 69.8 vs 430.0 ± 76.8 mm2 ; p = 0.007) and left coronary cusp diameter (30.2 ± 3.2 vs 31.1 ± 3.4 mm; p = 0.02) and lower height of left coronary artery ostia (12.0 ± 2.5 vs 13.4 ± 3.4 mm; p <0.001). Of baseline anatomic characteristics, body height showed the highest correlation with annulus area (Pearson correlation r = 0.64; p <0.001). Co-existence of lower height of left coronary artery ostia (<12 mm) and small diameter of left coronary cusp (<30 mm) were more frequent in Asian group compared with Caucasian group (35.6% vs 20.8%; p = 0.02). In contrast, there were no differences in calcium volumes of leaflet (367.2 ± 322.5 vs 359.1 ± 325.7 mm3 ; p = 0.84) and left ventricular outflow tract (8.9 ± 23.4 vs 10.1 ± 23.8 mm3 ; p = 0.66) between 2 groups. In conclusion, judicious consideration will be required to perform TAVI for short patients with lower height of left coronary artery ostia and small sinus of Valsalva.
...determining the most appropriate therapy (i.e., PMVR or surgical reoperation) for patients with SMVR failure warrants future investigation. ...we were able to demonstrate in a preliminary ...experience the safety and efficacy of PMVR with the MitraClip therapy in patients with surgical mitral valve annuloplasty failure.
Abstract Objectives The aim of this study was to assess the incidence and clinical impact of balloon post-dilation (BPD) after transcatheter aortic valve replacement (TAVR) with the CoreValve ...prosthesis (Medtronic Inc., Minneapolis, Minnesota). Background BPD is a widely adopted strategy to reduce the degree of paraprosthetic regurgitation in case of transcatheter heart valve underexpansion. However, controversies still remain regarding its real effectiveness and safety. Methods The ClinicalService (a nation-based data repository and medical care project) dataset was analyzed. All patients were dichotomized according to the need for BPD during the index procedure. Results Among 1,376 patients, BPD of the transcatheter heart valve was performed in 272 (19.8%). In 37% of cases, it was unsuccessful at reducing the paravalvular regurgitation to mild or less. No case of valve embolization, new intravalvular regurgitation, coronary occlusion, and aortic root injury occurred during BPD. There were no statistically significant differences between the 2 groups in the incidence of in-hospital all-cause and cardiovascular mortality, neurological events, myocardial infarction, bleeding, conversion to open-chest surgery, and the need for a permanent pacemaker. The need for BPD did not emerge as an independent risk factor for all-cause (adjusted hazard ratio HR: 1.33, 95% confidence interval CI: 0.81 to 2.19, p = 0.264) and cardiovascular (adjusted HR: 1.48, 95% CI: 0.74 to 2.97, p = 0.265) mortality at 1 year after the procedure. In addition, BPD did not predispose to higher odds of neurological events during 12 months after TAVR (HR: 0.92, 95% CI: 0.45 to 1.88, p = 0.815). Conclusions This large study showed that BPD after TAVR was safe and not associated with increased rates of cerebrovascular events, mortality, myocardial infarction, and aortic root injury.
Although transcatheter aortic valve implantation (TAVI) is still currently guided by transesophageal echocardiography (TEE) in a considerable number of hospitals, exclusive angiographic (Angio) ...guidance seems a reasonable approach in this setting. To date, however, no studies have directly compared the outcomes of TAVI according to the imaging modality used for procedural guidance. We, therefore, used data from a large multicenter data repository to compare the outcomes of TAVI guided exclusively by Angio and ATEE. All consecutive patients with severe aortic stenosis who underwent TAVI with the CoreValve Revalving System (CRS) in 9 Italian centers from September 2007 to March 2014, dichotomized according to the imaging support used to guide the procedure (ATEE and Angio), were included. Thirty-day and 12-month clinical outcomes were evaluated. Propensity matching analysis was performed to adjust for baseline differences. A total of 625 patients were included (256 and 369 patients were included in the ATEE and Angio groups, respectively). Patients from the ATEE more frequently underwent TAVI under general anesthesia compared with Angio group (37.9% vs 22.8%, respectively, p <0.001). Importantly, ∼80% of the patients experienced mild or even less aortic regurgitation as assessed by angiography after the procedure, without between-group differences. Postdilation and valve-in-valve rates were equivalent (24.7% vs 25%, p = 0.934 and 5.5% vs 3.4%, respectively, p = 0.217). No differences were revealed in the rates of death, cardiovascular death, and stroke or transient ischemic attack at 12-month follow-up. These results were sustained after propensity matching analysis. In conclusion, as long as a comprehensive procedural planning is performed, TAVI with CRS may be performed exclusively under angiographic guidance without the need for associated TEE.
The median logistic EuroSCORE I was 13.3% (interquartile range IQR: 8.4% to 26.3%). ...a certain amount of patients had prior cardiac intervention such as cardiac surgery (18.2%), percutaneous ...coronary intervention (36.4%), and balloon aortic valvuloplasty (18.2%). ...our preliminary experience utilizing data from a large multicenter registry suggests in a mid-term follow-up, favorable safety, and efficacy of TAVR in patients with severe AS and chronic dialysis.