We present a global analysis of leptonic and semileptonic kaon decay data, including all recent results published by the BNL-E865, KLOE, KTeV, ISTRA+ and NA48 experiments. This analysis, in ...conjunction with precise lattice calculations of the hadronic matrix elements now available, leads to a very precise determination of |
V
us
| and allows us to perform several stringent tests of the Standard Model.
We present a precise measurement of the ratio RK=Γ(K→eν(γ))/Γ(K→μν(γ)) and a study of the radiative process K→eνγ, performed with the KLOE detector. The results are based on data collected at the ...Frascati e+e− collider DAΦNE for an integrated luminosity of 2.2 fb−1. We find RK=(2.493±0.025stat±0.019syst)×10−5, in agreement with the Standard Model expectation. This result is used to improve constraints on parameters of the Minimal Supersymmetric Standard Model with lepton flavor violation. We also measured the differential decay rate dΓ(K→eνγ)/dEγ for photon energies 10<Eγ< 250 MeV. Results are compared with predictions from theory.
Data handling, reconstruction, and simulation for the KLOE experiment Ambrosino, F.; Antonelli, A.; Antonelli, M. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
12/2004, Letnik:
534, Številka:
3
Journal Article
Recenzirano
Odprti dostop
The broad physics program of the KLOE experiment is based on the high event rate at the Frascati φ
factory, and calls for an up-to-date system for data acquisition and processing. In this review of ...the KLOE offline environment, the architecture of the data-processing system and the programs developed for data reconstruction and Monte Carlo simulation are described, as well as the various procedures used for data handling and transfer between the different components of the system.
Using a large sample of pure, slow, short lived K0 mesons collected with KLOE detector at DAΦNE, we have measured the KS lifetime. From a fit to the proper time distribution we find ...τ(KS)=(89.562±0.029stat±0.043syst) ps. This is the most precise measurement to date of the short lived K0 meson lifetime, in good agreement with the world average derived from previous measurements. We observe no dependence of the lifetime on the direction of the KS in galactic coordinates.
The trigger system of the KLOE experiment Adinolfi, M; Ambrosino, F; Antonelli, M ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2002, Letnik:
492, Številka:
1
Journal Article
Recenzirano
Odprti dostop
We present the design of the trigger system for the KLOE experiment at the Frascati
φ-factory DAΦNE. The detector consists of a large-volume drift chamber and a calorimeter both immersed in a
0.52
T
...solenoidal field. The trigger, structured with a first- and a second-decision level, is based on the multiplicity of energy deposits in the calorimeter and of hits in the drift chamber. The selection criteria are described and the efficiency for detecting
φ decays is evaluated using data.