The preparation of aqueous graphene dispersions by exfoliation of pristine graphite in the presence of a wide range of surfactants is reported. High graphene concentrations, up to about 1
mg
mL
−1, ...were obtained with the use of some non-ionic surfactants. The dispersions consisted of single- and few-layer graphene platelets with their basal planes virtually free of even atomic-sized (point) defects. The potential utility of such highly concentrated dispersions toward the low-cost, large-scale manipulation and processing of graphene was demonstrated by processing them into electrically conductive, free-standing paper-like films.
Aliment Pharmacol Ther 2011; 34: 125–145
Summary
Background Cross‐sectional imaging techniques, including ultrasonography (US), computed tomography (CT) and magnetic resonance imaging (MRI), are ...increasingly used for evaluation of Crohn’s disease (CD).
Aim To perform an assessment of the diagnostic accuracy of cross‐sectional imaging techniques for diagnosis of CD, evaluation of disease extension and activity and diagnosis of complications, and to provide recommendations for their optimal use.
Methods Relevant publications were identified by literature search and selected based on predefined quality parameters, including a prospective design, sample size and reference standard. A total of 68 publications were chosen.
Results Ultrasonography is an accurate technique for diagnosis of suspected CD and for evaluation of disease activity (sensitivity 0.84, specificity 0.92), is widely available and non‐invasive, but its accuracy is lower for disease proximal to the terminal ileum. MRI has a high diagnostic accuracy for the diagnosis of suspected CD and for evaluation of disease extension and activity (sensitivity 0.93, specificity 0.90), and is less dependent on the examiner and disease location compared with US. CT has a similar accuracy to MRI for assessment of disease extension and activity. The three techniques have a high accuracy for identification of fistulas, abscesses and stenosis (sensitivities and specificities >0.80), although US has false positive results for abscesses. As a result of the lack of radiation, US or MRI should be preferred over CT, particularly in young patients.
Conclusions Cross‐sectional imaging techniques have a high accuracy for evaluation of suspected and established CD, reliably measure disease severity and complications; they may offer the possibility to monitor disease progression.
Stellar-mass black holes have all been discovered through X-ray emission, which arises from the accretion of gas from their binary companions (this gas is either stripped from low-mass stars or ...supplied as winds from massive ones). Binary evolution models also predict the existence of black holes accreting from the equatorial envelope of rapidly spinning Be-type stars (stars of the Be type are hot blue irregular variables showing characteristic spectral emission lines of hydrogen). Of the approximately 80 Be X-ray binaries known in the Galaxy, however, only pulsating neutron stars have been found as companions. A black hole was formally allowed as a solution for the companion to the Be star MWC 656 (ref. 5; also known as HD 215227), although that conclusion was based on a single radial velocity curve of the Be star, a mistaken spectral classification and rough estimates of the inclination angle. Here we report observations of an accretion disk line mirroring the orbit of MWC 656. This, together with an improved radial velocity curve of the Be star through fitting sharp Fe II profiles from the equatorial disk, and a refined Be classification (to that of a B1.5-B2 III star), indicates that a black hole of 3.8 to 6.9 solar masses orbits MWC 656, the candidate counterpart of the γ-ray source AGL J2241+4454 (refs 5, 6). The black hole is X-ray quiescent and fed by a radiatively inefficient accretion flow giving a luminosity less than 1.6 × 10(-7) times the Eddington luminosity. This implies that Be binaries with black-hole companions are difficult to detect in conventional X-ray surveys.
The pulsar/massive star binary system PSR B1259−63/LS 2883 is one of the best-studied gamma-ray binaries, a class of systems whose bright gamma-ray flaring can provide important insights into ...high-energy physics. Using the Australian Long Baseline Array, we have conducted very long baseline interferometric observations of PSR B1259−63 over 4.4 years, fully sampling the 3.4-year orbital period. From our measured parallax of 0.38 ± 0.05 mas- we use a Bayesian approach to infer a distance of |$2.6^{+0.4}_{-0.3}$| kpc. We find that the binary orbit is viewed at an angle of 154 ± 3° to the line of sight, implying that the pulsar moves clockwise around its orbit as viewed on the sky. Taking our findings together with previous results from pulsar timing observations, all seven orbital elements for the system are now fully determined. We use our measurement of the inclination angle to constrain the mass of the stellar companion to lie in the range 15–31 M_⊙. Our measured distance and proper motion are consistent with the system having originated in the Cen OB1 association and receiving a modest natal kick, causing it to have moved ∼8 pc from its birthplace over the past ∼3 × 10^5 years. The orientation of the orbit on the plane of the sky matches the direction of motion of the X-ray synchrotron-emitting knot observed by the Chandra X-ray Observatory to be moving away from the system.
Anodic exfoliation of graphite has emerged as an attractive method to access graphene nanosheets in large quantities, but oxidation reactions associated to this process compromise the structural ...quality of the resulting materials. Here, we demonstrate that the type of starting graphite material impacts the oxygen and defect content of anodically exfoliated graphenes obtained thereof. We investigated highly oriented pyrolytic graphite (HOPG) as well as graphite foil, flakes and powder as electrode in the anodic process. Importantly, materials with low levels of oxidation and disorder (similar to those typically achieved with cathodic exfoliation approaches) could be attained through proper choice of the graphite electrode. Specifically, using graphite foil afforded nanosheets of higher quality than that of HOPG-derived nanosheets. This discrepancy was interpreted to arise from the structural peculiarities of the former, where the presence of folds, voids and wrinkles would make its exfoliation process to be less reliant on oxidation reactions. Furthermore, cell viability tests carried out with murine fibroblasts on thin graphene films suggested that the anodically exfoliated graphenes investigated here (possessing low or high oxidation levels) are highly biocompatible. Overall, control upon the extent of oxidation and disorder should expand the scope of anodically exfoliated graphenes in prospective applications.
We report on broad multiwavelength observations of the 2010-2011 periastron passage of the γ-ray loud binary system PSR B1259−63. High-resolution interferometric radio observations establish extended ...radio emission trailing the position of the pulsar. Observations with the Fermi
Gamma-ray Space Telescope reveal GeV γ-ray flaring activity of the system, reaching the spin-down luminosity of the pulsar, around 30 d after periastron. There are no clear signatures of variability at radio, X-ray and TeV energies at the time of the GeV flare. Variability around periastron in the Hα emission line, can be interpreted as the gravitational interaction between the pulsar and the circumstellar disc. The equivalent width of the Hα grows from a few days before periastron until a few days later, and decreases again between 18 and 46 d after periastron. In near-infrared we observe the similar decrease of the equivalent width of Brγ line between the 40th and 117th day after the periastron. For the idealized disc, the variability of the Hα line represents the variability of the mass and size of the disc. We discuss possible physical relations between the state of the disc and GeV emission under assumption that GeV flare is directly related to the decrease of the disc size.
MWC 656 is the first known Be/black hole (BH) binary system. Be/BH binaries are important in the context of binary system evolution and sources of detectable gravitational waves because they are ...possible precursors of coalescing neutron star/BH binaries. X-ray observations conducted in 2013 revealed that MWC 656 is a quiescent high-mass X-ray binary (HMXB), opening the possibility to explore X-ray/radio correlations and the accretion/ejection coupling down to low luminosities for BH HMXBs. Here we report on a deep joint Chandra/VLA observation of MWC 656 (and contemporaneous optical data) conducted in 2015 July that has allowed us to unambiguously identify the X-ray counterpart of the source. The X-ray spectrum can be fitted with a power law with Γ ∼ 2, providing a flux of 4 × 10−15 erg cm−2 s−1 in the 0.5-8 keV energy range and a luminosity of LX 3 × 1030 erg s−1 at a 2.6 kpc distance. For a 5 M BH this translates into 5 × 10−9 LEdd. These results imply that MWC 656 is about 7 times fainter in X-rays than it was two years before and reaches the faintest X-ray luminosities ever detected in stellar-mass BHs. The radio data provide a detection with a peak flux density of 3.5 1.1 Jy beam−1. The obtained X-ray/radio luminosities for this quiescent BH HMXB are fully compatible with those of the X-ray/radio correlations derived from quiescent BH low-mass X-ray binaries. These results show that the accretion/ejection coupling in stellar-mass BHs is independent of the nature of the donor star.
The liquid-phase exfoliation of graphitic carbon nitride (g-C3N4) to afford colloidal dispersions of two-dimensional flakes constitutes an attractive route to facilitate the processing and ...implementation of this novel material toward different technological applications, but quantitative knowledge about its dispersibility in solvents is lacking. Here, we investigate the dispersion behavior of exfoliated g-C3N4 in a wide range of solvents and evaluate the obtained results on the basis of solvent surface energy and Hildebrand/Hansen solubility parameters. Estimates of the three Hansen parameters for exfoliated g-C3N4 from the experimentally derived data yielded δD ≈ 17.8 MPa(1/2), δP ≈ 10.8 MPa(1/2), and δH ≈ 15.4 MPa(1/2). The relatively high δH value suggested that, contrary to the case of other two-dimensional materials (e.g., graphene or transition metal dichalcogenides), hydrogen-bonding plays a substantial role in the efficient interaction, and thus dispersibility, of exfoliated g-C3N4 with solvents. Such an outcome was attributed to a high density of primary and/or secondary amines in the material, the presence of which was associated with incomplete condensation of the structure. Furthermore, cell proliferation tests carried out on thin films of exfoliated g-C3N4 using murine fibroblasts suggested that this material is highly biocompatible and noncytotoxic. Finally, the exfoliated g-C3N4 flakes were used as supports in the synthesis of Pd nanoparticles, and the resulting hybrids exhibited an exceptional catalytic activity in the reduction of nitroarenes.