This paper describes the 25 year effort to measure vacuum magnetic birefringence and dichroism with the PVLAS experiment. The experiment went through two main phases: the first using a rotating ...superconducting magnet and the second using two rotating permanent magnets. The experiment was not able to reach the predicted value from QED. Nonetheless the experiment has set the current best limits on vacuum magnetic birefringence and dichroism for a field of Bext=2.5 T, namely, Δn(PVLAS)=(12±17)×10−23 and |Δκ|(PVLAS)=(10±28)×10−23. The uncertainty on Δn(PVLAS) is about a factor 7 above the predicted value of Δn(QED)=2.5×10−23 @ 2.5 T.
We present a proposal to search for QCD axions with mass in the 200μeV range, assuming that they make a dominant component of dark matter. Due to the axion–electron spin coupling, their effect is ...equivalent to the application of an oscillating rf field with frequency and amplitude fixed by the axion mass and coupling respectively. This equivalent magnetic field would produce spin flips in a magnetic sample placed inside a static magnetic field, which determines the resonant interaction at the Larmor frequency. Spin flips would subsequently emit radio frequency photons that can be detected by a suitable quantum counter in an ultra-cryogenic environment. This new detection technique is crucial to keep under control the thermal photon background which would otherwise produce a too large noise.
The PVLAS collaboration is presently assembling a new apparatus (at the INFN section of Ferrara, Italy) to detect vacuum magnetic birefringence (VMB). VMB is related to the structure of the quantum ...electrodynamics (QED) vacuum and is predicted by the Euler-Heisenberg-Weisskopf effective Lagrangian. It can be detected by measuring the ellipticity acquired by a linearly polarized light beam propagating through a strong magnetic field. Using the very same optical technique it is also possible to search for hypothetical low-mass particles interacting with two photons, such as axion-like (ALP) or millicharged particles. Here we report the results of a scaled-down test setup and describe the new PVLAS apparatus. This latter is in construction and is based on a high-sensitivity ellipsometer with a high-finesse Fabry-Perot cavity (>4 × 105) and two 0.8 m long 2.5 T rotating permanent dipole magnets. Measurements with the test setup have improved, by a factor 2, the previous upper bound on the parameter Ae, which determines the strength of the nonlinear terms in the QED Lagrangian: A(PVLAS)e < 3.3 × 10−21 T−2 at 95% c.l. Furthermore, new laboratory limits have been put on the inverse coupling constant of ALPs to two photons and confirmation of previous limits on the fractional charge of millicharged particles is given.
Although experimental efforts have been active for about 30 years, a direct laboratory observation of vacuum magnetic birefringence, due to vacuum fluctuations, still needs confirmation: the ...predicted birefringence of vacuum is
Δ
n
=
4.0
×
10
-
24
@ 1 T. Key ingredients of a polarimeter for detecting such a small birefringence are a long optical path within the magnetic field and a time dependent effect. To lengthen the optical path a Fabry–Perot is generally used with a finesse ranging from
F
≈
10
4
to
F
≈
7
×
10
5
. Interestingly, there is a difficulty in reaching the predicted shot noise limit of such polarimeters. We have measured the ellipticity and rotation noises along with Cotton-Mouton and Faraday effects as a function of the finesse of the cavity of the PVLAS polarimeter. The observations are consistent with the idea that the cavity mirrors generate a birefringence-dominated noise whose ellipticity is amplified by the cavity itself. The optical path difference sensitivity at
10
Hz
is
S
Δ
D
=
6
×
10
-
19
m
/
Hz
, a value which we believe is consistent with an intrinsic thermal noise in the mirror coatings. Our findings prove that the continuous efforts to increase the finesse of the cavity to improve the sensitivity has reached a limit.
Aim of the QUAX (QUaerere AXion) proposal is to exploit the interaction of cosmological axions with the spin of electrons in a magnetized sample. Their effect is equivalent to the application of an ...oscillating rf field with frequency and amplitude which are fixed by axion mass and coupling constant, respectively. The rf receiver module of the QUAX detector consists of magnetized samples with the Larmor resonance frequency tuned to the axion mass by a polarizing static magnetic field. The interaction of electrons with the axion-equivalent rf field produces oscillations in the total magnetization of the samples. To amplify such a tiny field, a pump field at the same frequency is applied in a direction orthogonal to the polarizing field. The induced oscillatory magnetization along the polarizing field is measured by a SQUID amplifier operated at its quantum noise level.
We report on the resonant Fabry Perot cavity of the PVLAS (Polarization of the Vacuum with LASer) experiment operating at λ = 1064 nm with a record decay time of 2.7 ms, a factor more than two larger ...than any previously reported optical resonator. This corresponds to a coherence length of 8.1 · 10(5) m. The cavity length is 3.303 m, and the resulting finesse is 770,000.