UP - logo

Rezultati iskanja

Osnovno iskanje    Ukazno iskanje   

Trenutno NISTE avtorizirani za dostop do e-virov UPUK. Za polni dostop se PRIJAVITE.

1 2 3 4 5
zadetkov: 178
1.
  • BrachyView, a novel in‐body... BrachyView, a novel in‐body imaging system for HDR prostate brachytherapy: Experimental evaluation
    Safavi‐Naeini, M.; Han, Z.; Alnaghy, S. ... Medical physics (Lancaster), December 2015, Letnik: 42, Številka: 12
    Journal Article
    Recenzirano
    Odprti dostop

    Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in‐body source tracking system for HDR brachytherapy based on a multipinhole ...
Celotno besedilo

PDF
2.
Celotno besedilo

PDF
3.
  • Charge Collection in SOI Mi... Charge Collection in SOI Microdosimeters and their Radiation Hardness
    Pan, V. A.; Tran, L. T.; Pastuovic, Z. ... IEEE transactions on nuclear science, 04/2023, Letnik: 70, Številka: 4
    Journal Article
    Recenzirano

    A new batch of microdosimeters has been extensively studied for their charge collection efficiency (CCE) properties, as well as their radiation hardness for medical, space and accident applications. ...
Celotno besedilo
4.
  • Absorbed dose-to-water protocol applied to synchrotron-generated x-rays at very high dose rates
    Fournier, P; Crosbie, J C; Cornelius, I ... Physics in medicine & biology, 07/2016, Letnik: 61, Številka: 14
    Journal Article
    Recenzirano

    Microbeam radiation therapy (MRT) is a new radiation treatment modality in the pre-clinical stage of development at the ID17 Biomedical Beamline of the European synchrotron radiation facility (ESRF) ...
Preverite dostopnost
5.
  • The feasibility study and c... The feasibility study and characterization of a two-dimensional diode array in “magic phantom” for high dose rate brachytherapy quality assurance
    Espinoza, A.; Beeksma, B.; Petasecca, M. ... Medical physics (Lancaster), November 2013, Letnik: 40, Številka: 11
    Journal Article
    Recenzirano

    Purpose: High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly ...
Celotno besedilo
6.
  • Study of the X‐ray radiatio... Study of the X‐ray radiation interaction with a multislit collimator for the creation of microbeams in radiation therapy
    Pellicioli, P.; Donzelli, M.; Davis, J. A. ... Journal of synchrotron radiation, March 2021, 2021-Mar-01, 2021-03-01, 20210301, Letnik: 28, Številka: 2
    Journal Article
    Recenzirano
    Odprti dostop

    Microbeam radiation therapy (MRT) is a developing radiotherapy, based on the use of beams only a few tens of micrometres wide, generated by synchrotron X‐ray sources. The spatial fractionation of the ...
Celotno besedilo

PDF
7.
  • The evaluation of a 2D diod... The evaluation of a 2D diode array in “magic phantom” for use in high dose rate brachytherapy pretreatment quality assurance
    Espinoza, A.; Petasecca, M.; Fuduli, I. ... Medical physics (Lancaster), February 2015, Letnik: 42, Številka: 2
    Journal Article
    Recenzirano
    Odprti dostop

    Purpose: High dose rate (HDR) brachytherapy is a treatment method that is used increasingly worldwide. The development of a sound quality assurance program for the verification of treatment ...
Celotno besedilo

PDF
8.
  • A Solid-State Microdosimete... A Solid-State Microdosimeter for Dose and Radiation Quality Monitoring for Astronauts in Space
    Peracchi, S.; Matsufuji, N.; Kok, A. ... IEEE transactions on nuclear science, 01/2020, Letnik: 67, Številka: 1
    Journal Article
    Recenzirano

    This article presents a study of the response of the silicon on insulator (SOI) microdosimeter with 3-D sensitive volumes (SVs) to 400 MeV/u 16 O and 500 MeV/u 56 Fe ions mimicking galactic cosmic ...
Celotno besedilo
9.
  • BrachyView: development of an algorithm for real-time automatic LDR brachytherapy seed detection
    Brennen, T; Galli, L; Cutajar, D L ... Physics in medicine & biology, 11/2020, Letnik: 65, Številka: 21
    Journal Article
    Recenzirano

    BrachyView is a novel in-body imaging system developed to provide real-time intraoperative dosimetry for low dose rate prostate brachytherapy treatments. Seed positions can be reconstructed after ...
Preverite dostopnost
10.
  • Application of an SOI Micro... Application of an SOI Microdosimeter for Monitoring of Neutrons in Various Mixed Radiation Field Environments
    Pan, V. A.; Vohradsky, J.; James, B. ... IEEE transactions on nuclear science, 03/2022, Letnik: 69, Številka: 3
    Journal Article
    Recenzirano

    Radiation monitoring in space radiation is complex due to galactic cosmic rays (GCRs), solar particle events (SPEs), and albedo particles. Thermal neutrons are an important component in the Moon ...
Celotno besedilo
1 2 3 4 5
zadetkov: 178

Nalaganje filtrov