The goal of the CYGNO project is to deploy at Laboratori Nazionali del Gran Sasso (LNGS) an high resolution Time Projection Chamber (TPC) with Gas Electron Multipliers (GEMs) amplification and ...optical 3D readout of an Helium/Fluorine based gas mixture for directional Dark Matter (DM) searches at low 1-10 GeV WIMP masses. The determination of the incoming direction of WIMP particles can in fact offer not only additional handles for discrimination of the annoying backgrounds, but especially an unique key for a positive, unambiguous identification of a DM signal.
Systematic studies on the GEM foil material are performed to measure the moisture diffusion rate and saturation level. These studies are important because the presence of this compound inside the ...detector’ s foil can possibly change its mechanical and electrical properties, and in such a way, the detector performance can be affected. To understand this phenomenon, a model is developed with COMSOL Multiphysics v. 4.3 1, which described the adsorption and diffusion within the geometry of GEM foil, the concentration profiles and the time required to saturate the foil. The COMSOL model is verified by experimental observations on a GEM foil sample. This note will describe the model and its experimental verification results.
Study of gas purifiers for the CMS RPC detector Benussi, L.; Bianco, S.; Colafranceschi, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
01/2012, Letnik:
661
Journal Article
Recenzirano
Odprti dostop
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out ...over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clarify the presence of pollutants, the chemistry of purifiers used in the CL, and the regeneration procedure. Preliminary results on contaminants release and purifier characterization are reported.
Performances of the Gas Gain Monitoring system of the CMS RPC muon detectors after one year of operation at the scaled down closed loop recirculation gas system are presented. The GGM is made of 12 ...single-gap RPC's arranged in a cosmic ray telescope, with charge readout for online monitoring of working point. Preliminary results on sensitivity to gas changes and to environmental variables will be reported on.