For the first time secondary scintillation, generated within the holes of a thick gas electron multiplier (TGEM) immersed in liquid argon, has been observed and measured using a silicon ...photomultiplier device (SiPM). 250 electron-ion pairs, generated in liquid argon via the interaction of a 5.9KeV Fe-55 gamma source, were drifted under the influence of a 2.5KV/cm field towards a 1.5mm thickness TGEM, the local field sufficiently high to generate secondary scintillation light within the liquid as the charge traversed the central region of the TGEM hole. The resulting VUV light was incident on an immersed SiPM device coated in the waveshifter tetraphenyl butadiene (TPB), the emission spectrum peaked at 460nm in the high quantum efficiency region of the device. For a SiPM over-voltage of 1V, a TGEM voltage of 9.91KV, and a drift field of 2.5KV/cm, a total of 62 ± 20 photoelectrons were produced at the SiPM device per Fe-55 event, corresponding to an estimated gain of 150 ± 66 photoelectrons per drifted electron.
Calorimeter development for the SuperNEMO double beta decay experiment Barabash, A.S.; Basharina-Freshville, A.; Blot, S. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
10/2017, Letnik:
868, Številka:
C
Journal Article
Recenzirano
Odprti dostop
SuperNEMO is a double-β decay experiment, which will employ the successful tracker–calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-β ...decay isotope, reaching a sensitivity to the neutrinoless double-β decay (0νββ) half-life of the order of 1026 yr, corresponding to a Majorana neutrino mass of 50–100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, ΔE∕E, around 3%∕E(MeV)σ, or 7%∕E(MeV) FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. We describe the R&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.
Cresst-II: dark matter search with scintillating absorbers Angloher, G.; Bucci, C.; Cozzini, C. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/2004, Letnik:
520, Številka:
1-3
Journal Article
Recenzirano
In the CRESST-II experiment, scintillating CaWO4 crystals are used as absorbers for direct weakly interacting massive particles (WIMP) detection. Nuclear recoils can be discriminated against electron ...recoils by measuring phonons and scintillation light simultaneously. The absorber crystal and the silicon light detector are read out by tungsten superconducting phase transition thermometers. Results on the sensitivity of the phonon and the light channel, radiopurity, the scintillation properties of CaWO4, and on the WIMP sensitivity are presented.
CaWO4 crystals as scintillators for cryogenic dark matter search Ninković, J.; Angloher, G.; Bucci, C. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
01/2005, Letnik:
537, Številka:
1-2
Journal Article
Recenzirano
Although it is well known that CaWO4 is a scintillator it is not often used, mainly because it has a slow light response. However, a high Z and a good light output make this crystal a candidate for ...use in direct dark matter search experiments. The Cryogenic Rare Event Search using Superconducting Thermometers (CRESST II) experiment looks for hypothetical massive elementary particles called Weakly Interacting Massive Particles (WIMPs). In an elastic collision of WIMPs with ordinary matter a WIMP transfers part of its energy to a nucleus. Such nuclear recoils are the signals dark matter searches look for. CRESST is using CaWO4 crystals with coincident detection of phonons and scintillation light to suppress radioactive background. Light output and energy resolution of different CaWO4 samples were systematically measured. Best samples have an energy resolution at the 137Cs line (661keV)<8%. As CRESST is a rare event search experiment it has to prevent the background caused by natural radioactivity; therefore, a study of the radiopurity of CaWO4 crystals has been performed. X-ray luminescence properties of crystal samples, in the temperature range 77–500K, will be presented.
Multichannel SQUID readout for CRESST II Henry, S; Kraus, H; Majorovits, B ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
03/2004, Letnik:
520, Številka:
1-3
Journal Article
Recenzirano
We have developed a 66-channel SQUID system to read out the detectors for the second phase of the CRESST dark matter search using SQUID sensors, electronics and cryocables supplied by different ...manufacturers. The system has been extensively tested at Oxford to characterise the sensitivity, bandwidth, slew rate, noise, thermal drift, and crosstalk. By using the SQUID sensors as magnetometers we can confirm the input circuit for the detectors is superconducting, thus ensuring there will be no noise from parasitic resistance. Multichannel SQUID systems have further applications in particle physics experiments, such as precision magnetometry in the search for the neutron electric dipole moment.
The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at ...the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39Ar. Despite the outstanding capability of discriminating γ/β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37Ar and 3H are shown not to be relevant due to short half-life and assumed purification methods.
Abstract The NEMO-3 results for the double- $$\beta $$ β decay of $$^{150}$$ 150 Nd to the 0 $$^+_1$$ 1 + and 2 $$^+_1$$ 1 + excited states of $$^{150}$$ 150 Sm are reported. The data recorded during ...5.25 year with 36.6 g of the isotope $$^{150}$$ 150 Nd are used in the analysis. The signal of the $$2\nu \beta \beta $$ 2 ν β β transition to the 0 $$^+_1$$ 1 + excited state is detected with a statistical significance exceeding 5 $$\sigma $$ σ . The half-life is measured to be $$T_{1/2}^{2\nu \beta \beta }(0^+_1) = \left 1.11 ^{+0.19}_{-0.14} \,\left( \hbox {stat}\right) ^{+0.17}_{-0.15}\,\left( \hbox {syst}\right) \right \times 10^{20}$$ T 1 / 2 2 ν β β ( 0 1 + ) = 1 . 11 - 0.14 + 0.19 stat - 0.15 + 0.17 syst × 10 20 year, which is the most precise value that has been measured to date. 90% confidence-level limits are set for the other decay modes. For the $$2\nu \beta \beta $$ 2 ν β β decay to the 2 $$^+_1$$ 1 + level the limit is $$T^{2\nu \beta \beta }_{1/2}(2^+_1) > 2.42 \times 10^{20}~\hbox {year}$$ T 1 / 2 2 ν β β ( 2 1 + ) > 2.42 × 10 20 year . The limits on the $$0\nu \beta \beta $$ 0 ν β β decay to the 0 $$^+_1$$ 1 + and 2 $$^+_1$$ 1 + levels of $$^{150}$$ 150 Sm are significantly improved to $$T_{1/2}^{0\nu \beta \beta }(0^+_1) > 1.36 \times 10^{22}~\hbox {year}$$ T 1 / 2 0 ν β β ( 0 1 + ) > 1.36 × 10 22 year and $$T_{1/2}^{0\nu \beta \beta }(2^+_1) > 1.26 \times 10^{22}~\hbox {year}$$ T 1 / 2 0 ν β β ( 2 1 + ) > 1.26 × 10 22 year .