We present polarimetric differential imaging (PDI) data of the circumstellar disk around the Herbig Ae/Be star HD100546 obtained with Very Large Telescope/NACO. We resolve the disk in polarized light ...in the H and Ks filter between ~01 and 14 (i.e., ~10-140 AU). The innermost disk regions are directly imaged for the first time and the mean apparent disk inclination and position angle are derived. The surface brightness along the disk major axis drops off roughly with S(r)r --3 but has a maximum around 015 suggesting a marginal detection of the main disk inner rim at ~15 AU. We find a significant brightness asymmetry along the disk minor axis in both filters with the far side of the disk appearing brighter than the near side. This enhanced backward scattering and a low total polarization degree of the scattered disk flux of 14+19 -- 8% suggest that the dust grains on the disk surface are larger than typical interstellar medium grains. Empirical scattering functions reveal the backward scattering peak at the largest scattering angles and a second maximum for the smallest scattering angles. This indicates a second dust grain population preferably forward scattering and smaller in size. It shows that, relatively, in the inner disk regions (40-50 AU) a higher fraction of larger grains is found compared to the outer disk regions (100-110 AU). Finally, our images reveal distinct substructures between 25 and 35 AU physical separation from the star and we discuss the possible origin for the two features in the context of ongoing planet formation.
This article focuses on increasing the computational efficiency of 3D multi-static magnetic finite element analysis (FEA) for electrical machines (EMs), which have a magnetic field evolving in 3D ...space. Although 3D FEA is crucial for analyzing these machines and their operational behavior, it is computationally expensive. A novel approach is proposed in order to solve the magnetic field equations by exclusively using the magnetic scalar potential. For this purpose, virtual variable permanent magnets (vPMs) are introduced to model the impact of the machine’s coils. The effect on which this approach is based is derived from and explained by Maxwell’s equations. To validate the new approach, an axial flux machine (AFM) is simulated using both 2D and 3D FEA with the magnetic vector potential and current-carrying coils as a reference. The results demonstrate a high level of agreement between the new approach and the reference simulations as well as an acceleration of the computation by a factor of 15 or even more. Additionally, the research provides valuable insights into meshing techniques and torque calculation for EMs in FEA.
Calcium (Ca) is an essential element for almost all living organisms. Here, we examined global variation and controls of freshwater Ca concentrations, using 440 599 water samples from 43 184 inland ...water sites in 57 countries. We found that the global median Ca concentration was 4.0 mg L
with 20.7% of the water samples showing Ca concentrations ≤ 1.5 mg L
, a threshold considered critical for the survival of many Ca-demanding organisms. Spatially, freshwater Ca concentrations were strongly and proportionally linked to carbonate alkalinity, with the highest Ca and carbonate alkalinity in waters with a pH around 8.0 and decreasing in concentrations towards lower pH. However, on a temporal scale, by analyzing decadal trends in >200 water bodies since the 1980s, we observed a frequent decoupling between carbonate alkalinity and Ca concentrations, which we attributed mainly to the influence of anthropogenic acid deposition. As acid deposition has been ameliorated, in many freshwaters carbonate alkalinity concentrations have increased or remained constant, while Ca concentrations have rapidly declined towards or even below pre-industrial conditions as a consequence of recovery from anthropogenic acidification. Thus, a paradoxical outcome of the successful remediation of acid deposition is a globally widespread freshwater Ca concentration decline towards critically low levels for many aquatic organisms.
A comprehensive study was performed to determine an optimum enantioseparation method for fluorine-substituted amphetamine and cathinone derivatives (fluor-amphetamine and fluor-cathinone ...derivatives), using a binary system consisting of carboxymethyl-β-CD (CM-β-CD) and a deep eutectic solvent (DES), namely choline chloride-ethylene glycol (ChCl-EG). Under this framework, the optimization and modeling of the separation conditions in a binary system were performed with the objective of maximizing resolution and minimizing analysis time. This was achieved through the application of response surface methodology. In particular, the effect of chiral selector concentration and percentage of DES on resolution and analysis time were investigated and optimized using a complete experimental design. The optimum enantioseparation conditions were determined to be 13.84 mM CM-β-CD and 0.15% v/v ChCl-EG for fluorine-substituted amphetamine derivatives and 14.36 mM and 0.75% v/v ChCl-EG for fluorine-substituted cathinone derivatives, respectively. This combination resulted in a baseline separation for eight out of the nine analytes studied. Overall, the results demonstrated the synergistic effect of the CM-β-CD/DES dual system and highlighted the significance of DESs as additives in capillary electrophoresis.
In the recent years, hundreds of Novel Psychoactive Substances (NPS) have entered both the European and the global drug market. These drugs, which are mainly used for recreational matters, have ...caused serious social problems. Every year, the spectrum of these misused drugs is enlarged by new derivatives, which are produced by modifications of basic structures of already well‐known substances. Additionally, a lot of them possess a stereogenic center which leads to 2 enantiomeric forms. The fact that the pharmacological effects and potencies of the enantiomers of these chiral NPS may differ can be assumed from a broad spectrum of active pharmaceutical ingredients. For this reason, analytical method development regarding enantiomeric separation for these classes of substances is of great pharmaceutical and medical interest. The aim of this work was to create an easy‐to‐prepare chiral capillary electrophoresis method for the enantioseparation of NPS which contains a primary amino group by means of (+)‐18‐crown‐6‐tetracarboxylic acid as chiral selector. Novel Psychoactive Substances were purchased at various Internet stores or represent samples seized by Austrian police. The effects of selector concentration, the electrolyte composition, and the addition of organic modifiers to the background electrolyte on enantioseparation were investigated. Under optimized conditions, the use of 20‐mM (+)‐18‐crown‐6‐tetracarboxylic acid, 10‐mM Tris, and 30‐mM citric acid buffer at pH 2.10 turned out to be effective. Fifteen of 24 tested NPS were resolved in their enantiomers within 15 minutes. It was found that all NPS were traded as racemic mixtures.
Schematical diagram showing a tripod interaction between (+)‐18‐crown‐6‐tetracarboxylic acid and a primary amine.
We present H- and K sub(s)-band polarized differential images of the Herbig Ae/Be star HD142527, revealing its optically thick outer disk and the nearly empty gap. The very small inner working angle ...(~0".1) and high-resolution achievable with an 8 m class telescope, together with a careful polarimetric calibration strategy, allow us to achieve images that surpass the quality of previous scattered-light images. Previously known substructures are resolved more clearly and new structures are seen. Specifically, we are able to resolve (1) half a dozen spiral structures in the disk, including previously known outer-disk spirals as well as new spiral arms and arcs close to the inner rim of the disk, (2) peculiar holes in the polarized surface brightness at position angles (P.A.'s) of ~0degrees and ~160degrees, (3) the inner rim on the eastern side of the disk, and (4) the gap between the outer and inner disk, ranging from the inner working angle of 0."1 out to between 0."7 and 1."0, which is nearly devoid of dust. We then use a Markov Chain Monte Carlo algorithm to determine several structural parameters of the disk, using very simple assumptions, including its inclination, eccentricity, and the scale height of the inner rim. We compare our results with previous work on this object and try to produce a consistent picture of the system and its transition disk.
Display omitted
The screening part of an earlier defined chiral separation strategy in capillary electrochromatography (CEC) was used for the separation of ten cathinone- and amphetamine derivatives. ...They were analyzed using 4 polysaccharide-based chiral stationary phases (CSPs), containing cellulose tris(3,5-dimethylphenylcarbamate) (ODRH), amylose tris(3,5-dimethylphenylcarbamate) (ADH), amylose tris(5-chloro-2-methylphenylcarbamate) (LA2), and cellulose tris(4-chloro-3-methylphenylcarbamate) (LC4) as chiral selectors. After applying the screening to each compound, ADH and LC4 showed the highest success rate. In a second part of the study, a comparison between CEC and other analytical techniques used for chiral separations i.e., supercritical fluid chromatography (SFC), polar organic solvent chromatography (POSC), reversed-phase (RPLC) and normal-phase liquid chromatography (NPLC), was made. For this purpose, earlier defined screening approaches for each technique were applied to separate the 10 test substances. This allowed an overall comparison of the success rates of the screening steps of the 5 techniques for these compounds. The results showed that CEC had a similar enantioselectivity rate as NPLC and RPLC, producing the highest number of separations (9 out of 10 racemates). SFC resolved 7 compounds, while POSC gave only 2 separations. On the other hand, the baseline separation success rates for NPLC and RPLC was better than for CEC. For a second comparison, the same chiral stationary phases as in the CEC screening were also tested with all techniques at their specific screening conditions, which allowed a direct comparison of the performance of CEC versus the same CSPs in the other techniques. This comparison revealed that RPLC was able to separate all tested compounds, and also produced the highest number of baseline separations on the CSP that were used in the CEC screening step. CEC and NPLC showed the same success rate: nine out of ten substances were separated. When CEC and NPLC are combined, separation of the ten compounds can be achieved. SFC and POSC resolved eight and three compounds, respectively. POSC was the least attractive option as it expressed only limited enantioselectivity toward these compounds.