The most important information still missing in the field of the low-energy antikaon-nucleon inter actions studies is the experimental determination of the hadronic energy shift and width of kaonic ...deuterium. This measurement will be performed by the SIDDHARTA-2 experiment, installed at the DAΦNE collider and presently in data taking campaign. The precise measurement of the shift and width of the 1s level with respect to the purely electromagnetic calculated values, generated by the presence of the strong interaction, through the measurement of the X-ray transitions to this level, in kaonic hydrogen, was performed by the SIDDHARTA collaboration, the kaonic deuterium is underway by SIDDHARTA-2. These measurement will allow the first precise experimental extraction of the isospin dependent antikaon-nucleon scattering lengths, funda mental quantities for understanding low-energy QCD in the strangeness sector. The experimental challenge of the kaonic deuterium measurement is the very small X-rays yield, the even larger width (compared to kaonic hy drogen), and the difficulty to perform X-rays spectroscopy with weak signals in the high radiation environment of DAΦNE. It was, therefore, crucial to develop a new apparatus involving large-area X-rays detector system, to optimize the signal and to control and by improve the signal-to-background ratio by gaining in solid angle, increasing the timing capability, and as well implementing additional charge particle tracking veto systems.
A
bstract
The ratio
R
= Γ(
K
S
→ πeν
)
/
Γ(
K
S
→ π
+
π
−
) has been measured with a sample of 300 million
K
S
mesons produced in
ϕ → K
L
K
S
decays recorded by the KLOE experiment at the DAΦNE
e
+
e
...−
collider.
K
S
→ πeν
events are selected by a boosted decision tree built with kinematic variables and time-of-flight measurements. Data control samples of
K
L
→ πeν
decays are used to evaluate signal selection efficiencies. With 49647
±
316 signal events we measure
R
= (1
.
0421
±
0
.
0066
stat
±
0
.
0075
syst
)
×
10
−
3
. The combination with our previous measurement gives
R
= (1
.
0338
±
0
.
0054
stat
±
0
.
0064
syst
)
×
10
−
3
. From this value we derive the branching fraction
B
(
K
S
→ πeν
) = (7
.
153
±
0
.
037
stat
±
0
.
044
syst
)
×
10
−
4
and
f
+
(0)
|V
us
|
= 0
.
2170
±
0
.
009.
Purpose
In living organisms, the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the ...pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511 keV photons. In this article, we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include the (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using 2
γ
annihilations and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner.
Methods
Simulations are conducted assuming that radiopharmaceutical is labeled with
44
S
c
isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution, the four cases were considered assuming that CRT is equal to 500 ps, 140 ps, 50 ps, and 10 ps.
Results
The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences (2
γ
+
γ
prompt
) is larger by a factor of 13.5 (for LYSO PET) and by factor of 5.2 (for plastic PET) with respect to the sensitivity for the standard 2
γ
imaging by LYSO PET scanners with AFOV = 20 cm. The spatial resolution of the ortho-positronium image is comparable with the resolution achievable when using TOF-FBP algorithms already for CRT = 50 ps. For the 20-min scan, the resolution better than 20 ps is expected for the mean ortho-positronium lifetime image determination.
Conclusions
Ortho-positronium mean lifetime imaging based on the annihilations into two photons and prompt gamma is shown to be feasible with the advent of the high sensitivity total-body PET systems and time resolution of the order of tens of picoseconds.
Abstract
Currently, the most used methods of plastic scintillator (PS) manufacturing are cell casting and bulk polymerisation, extrusion, injection molding, whereas digital light processing (DLP) 3D ...printing technique has been recently introduced. For our research, we measured blue-emitting EJ-200, EJ-208, green-emitting EJ-260, EJ-262 cell cast and two types of blue-emitting DLP-printed PSs. The light output of the samples, with the same dimension of 10 mm × 10 mm × 10 mm, was compared. The light output of the samples, relative to the reference EJ-200 cell-cast scintillator, equals about 40–49 and 70–73% for two types of 3D-printed, and two green-emitting cell-casted PSs, respectively. Performance of the investigated scintillators is sufficient to use them in a plastic scintillation dosemeter operating in high fluence gamma radiation fields.
Research conducted in the framework of the Jagiellonian-PET (J-PET) project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a ...full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, which have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required the development of new calibration methods including time, thresholds, and gain synchronization. The system and elaborated calibration methods, including first results of the 24-module J-PET prototype, are presented and discussed. The achieved coincidence resolving time equals to <inline-formula> <tex-math notation="LaTeX">{\mathrm {CRT}}=490\pm 9 </tex-math></inline-formula> ps. This value can be translated to the position reconstruction accuracy <inline-formula> <tex-math notation="LaTeX">\sigma (\Delta l) =18 </tex-math></inline-formula> mm, which is fairly position independent.
We present the tests performed by the SIDDHARTA-2 collaboration at the
DA
Φ
NE
collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in ...a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy mass kaonic atoms. The CdZnTe detector was installed for the first time in an accelerator environment to perform tests on the background rejection capabilities, which were achieved by exploiting the SIDDHARTA-2 Luminosity Monitor. A spectrum with an
241
Am
source has been acquired, with beams circulating in the main rings, and peak resolutions of 6% at 60 keV and of 2.2% at 511 keV have been achieved. The background suppression factor, which turned out to be of the order of
≃
10
5
-
6
, opens the possibility to plan for future kaonic atom measurements with CdZnTe detectors.
The KS → 3π0 decay is a pure CP violating process which, assuming CPT invariance, gives access to the CP – violating phase of the weak decay amplitude into I=1 final states. This decay has not been ...observed so far, and the best upper limit on the branching ratio BR(KS → 3π0) < 1.2 · 10−7 is two orders of magnitude larger than predictions based on the Standard Model. In this article we present the search for the KS → 3π0 decay performed with the KLOE detector operating at the DAΦNE ϕ – factory at the Frascati Laboratory. We describe the analysis techniques used for the background rejection and signal events selection leading to the result of an almost five times lower upper limit on the KS → 3π0 branching ratio. We also discuss the perspectives for a new measurement using the KLOE – 2 apparatus equipped with a new inner tracker and the calorimeters at low θ angle.
Light kaonic atoms spectroscopy provides a unique approach to study the low-energy strong interaction in the strangeness sector. Precise measurements of X-ray emission from light kaonic atoms provide ...valuable information on kaon-nucleus interaction at threshold without the need for extrapolation as required in scattering experiments. The SIDDHARTA-2 experiment at the DAΦNE collider of INFN-LNF is now poised to perform the challenging measurements of the K
−
- d 2p → 1s transition to extract the isospin-dependent antikaonnucleon scattering lengths. To achieve this goal, the background reduction is a crucial factor. This paper provides an overview of the SIDDHARTA-2 Veto-1 system, which uses scintillators outside the vacuum chamber to detect charged particles produced by K− absorption by the nucleus. The arrival time of these particles is correlated with the position where the kaonic atom has been created inside the setup, allowing for the rejection of kaons stopped outside the target cell, which is a critical component for reducing the background and improve the accuracy of the measurement.