Previous work used the sampling technique diffusive gradients in thin films analysed by laser ablation mass spectrometry to measure sulfide, P, V and As at a microniche of reactive organic carbon in ...a freshwater sediment. Here we present new developments of this technique. The number of analytes has been extended and we demonstrate the technique for depth profiling of analytes in both one and two dimensions. The physical dimensions of the cell in the laser ablation unit restrict the maximum length of gel that can be analysed. We address this problem by proposing a method for obtaining better data continuity when analysing multiple segments of gel from the same probe. (13)C is used as the internal standard for each gel segment. For the cross-standardisation of different gel segments (58)Fe signals are obtained from ablation of a small piece of standard ferrihydrite gel analysed during the same run as the sample gel. As the ferrihydrite gel is a subsection of a much larger gel (i.e. the Fe concentration is consistent for all subsections), any difference in signal can be attributed to changes in detector sensitivity, allowing consistent standardisation of gels analysed in different runs and on different days.
Using previously established procedures that utilise linear free energy relationships, we estimated binding constants for the Windermere Humic Aqueous Model VII (WHAM/Model VII) for several ...radionuclide cations (Pd(2+), Sn(2+), U(4+), NpO(2)(2+), Pu(4+) and PuO(2)(2+)). This extends the number of cations that can be calculated with the model above the 40 included in the original Model VII work. When combined with equilibrium constants for inorganic species this allows the calculation of equilibrium distributions of chemical species under a wide range of conditions.
Establishing a diverse gut microbiota after birth is being increasingly recognised as important for preventing illnesses later in life. It is well established that bacterial diversity rapidly ...increases post-partum; however, few studies have examined the infant gut virome/phageome during this developmental period. We performed a metagenomic analysis of 20 infant faecal viromes at one year of age to determine whether spontaneous vaginal delivery (SVD) or caesarean section (CS) influenced viral composition. We find that birth mode results in distinctly different viral communities, with SVD infants having greater viral and bacteriophage diversity. We demonstrate that CrAssphage is acquired early in life, both in this cohort and two others, although no difference in birth mode is detected. A previous study has shown that bacterial OTU's (operational taxonomic units) identified in the same infants could not discriminate between birth mode at 12 months of age. Therefore, our results indicate that vertical transmission of viral communities from mother to child may play a role in shaping the early life microbiome, and that birth mode should be considered when studying the early life gut virome.
Soils are structurally heterogeneous across a wide range of spatio-temporal scales. Consequently, external environmental conditions do not have a uniform effect throughout the soil, resulting in a ...large diversity of micro-habitats. It has been suggested that soil function can be studied without explicit consideration of such fine detail, but recent research has indicated that the micro-scale distribution of organisms may be of importance for a mechanistic understanding of many soil functions. Current techniques still lack the adequate sensitivity and resolution for data collection at the micro-scale, and the question ‘How important are various soil processes acting at different scales for ecological function?’ is therefore challenging to answer. The nano-scale secondary ion mass spectrometer (NanoSIMS) represents the latest generation of ion microprobes, which link high-resolution microscopy with isotopic analysis. The main advantage of NanoSIMS over other secondary ion mass spectrometers is its ability to operate at high mass resolution, whilst maintaining both excellent signal transmission and spatial resolution (down to 50
nm). NanoSIMS has been used previously in studies focussing on presolar materials from meteorites, in material science, biology, geology and mineralogy. Recently, the potential of NanoSIMS as a new tool in the study of biophysical interfaces in soils has been demonstrated. This paper describes the principles of NanoSIMS and discusses the potential of this tool to contribute to the field of biogeochemistry and soil ecology. Practical considerations (sample size and preparation, simultaneous collection of isotopes, mass resolution, isobaric interference and quantification of the isotopes of interest) are discussed. Adequate sample preparation, avoiding bias due to artefacts, and identification of regions-of-interest will be critical concerns if NanoSIMS is used as a new tool in biogeochemistry and soil ecology. Finally, we review the areas of research most likely to benefit from the high spatial and high mass resolution attainable with this new approach.
Oxygenation measurements are widely used in patient care. However, most clinically available instruments currently consist of contact probes that only provide global monitoring of the patient (e.g., ...pulse oximetry probes) or local monitoring of small areas (e.g., spectroscopy-based probes). Visualization of oxygenation over large areas of tissue, without a priori knowledge of the location of defects, has the potential to improve patient management in many surgical and critical care applications. In this study, we present a clinically compatible multispectral spatial frequency domain imaging (SFDI) system optimized for surgical oxygenation imaging. This system was used to image tissue oxygenation over a large area (16×12 cm) and was validated during preclinical studies by comparing results obtained with an FDA-approved clinical oxygenation probe. Skin flap, bowel, and liver vascular occlusion experiments were performed on Yorkshire pigs and demonstrated that over the course of the experiment, relative changes in oxygen saturation measured using SFDI had an accuracy within 10% of those made using the FDA-approved device. Finally, the new SFDI system was translated to the clinic in a first-in-human pilot study that imaged skin flap oxygenation during reconstructive breast surgery. Overall, this study lays the foundation for clinical translation of endogenous contrast imaging using SFDI.
Although various methods exist for monitoring flaps during reconstructive surgery, surgeons primarily rely on assessment of clinical judgment. Early detection of vascular complications improves rate ...of flap salvage. Spatial frequency domain imaging (SFDI) is a promising new technology that provides oxygenation images over a large field of view. The goal of this clinical pilot study is to use SFDI in perforator flap breast reconstruction.
Three women undergoing unilateral breast reconstruction after mastectomy were enrolled for our study. The SFDI system was deployed in the operating room, and images acquired over the course of the operation. Time points included images of each hemiabdominal skin flap before elevation, the selected flap after perforator dissection, and after microsurgical transfer.
Spatial frequency domain imaging was able to measure tissue oxyhemoglobin concentration (ctO2Hb), tissue deoxyhemoglobin concentration, and tissue oxygen saturation (stO2). Images were created for each metric to monitor flap status and the results quantified throughout the various time points of the procedure. For 2 of 3 patients, the chosen flap had a higher ctO2Hb and stO2. For 1 patient, the chosen flap had lower ctO2Hb and stO2. There were no perfusion deficits observed based on SFDI and clinical follow-up.
The results of our initial human pilot study suggest that SFDI has the potential to provide intraoperative oxygenation images in real-time during surgery. With the use of this technology, surgeons can obtain tissue oxygenation and hemoglobin concentration maps to assist in intraoperative planning; this can potentially prevent complications and improve clinical outcome.
Men diagnosed with low-risk prostate cancer (PC) are increasingly electing active surveillance (AS) as their initial management strategy. While this may reduce the side effects of treatment for PC, ...many men on AS eventually convert to active treatment. PC is one of the most heritable cancers, and genetic factors that predispose to aggressive tumors may help distinguish men who are more likely to discontinue AS. To investigate this, we undertook a multi-institutional genome-wide association study (GWAS) of 5,222 PC patients and 1,139 other patients from replication cohorts, all of whom initially elected AS and were followed over time for the potential outcome of conversion from AS to active treatment. In the GWAS we detected 18 variants associated with conversion, 15 of which were not previously associated with PC risk. With a transcriptome-wide association study (TWAS), we found two genes associated with conversion (MAST3, p = 6.9 × 10−7 and GAB2, p = 2.0 × 10−6). Moreover, increasing values of a previously validated 269-variant genetic risk score (GRS) for PC was positively associated with conversion (e.g., comparing the highest to the two middle deciles gave a hazard ratio HR = 1.13; 95% confidence interval CI = 0.94–1.36); whereas decreasing values of a 36-variant GRS for prostate-specific antigen (PSA) levels were positively associated with conversion (e.g., comparing the lowest to the two middle deciles gave a HR = 1.25; 95% CI, 1.04–1.50). These results suggest that germline genetics may help inform and individualize the decision of AS—or the intensity of monitoring on AS—versus treatment for the initial management of patients with low-risk PC.
Genetic factors may distinguish who should receive active surveillance (AS) versus treatment following prostate cancer diagnosis. We undertook the first study to investigate this and report novel variants, genes, and risk scores associated with AS outcomes. These findings could help inform and individualize the decision of AS.
Astrometric satellite positions are derived from timings of their eclipses in the shadow of Jupiter. The 548 data points span 20
years and are accurate to about 0.006
arcsec for Io and Europa and ...about 0.015
arcsec or better for Ganymede and Callisto. The precision of the data set and its nearly continuous distribution in time allows measurement of regular oscillations with an accuracy of 0.001
arcsec. This level of sensitivity permits detailed evaluation of modern ephemerides and reveals anomalies at the 1.3
year period of the resonant perturbations between Io, Europa and Ganymede. The E5 ephemeris shows large errors at that period for all three satellites as well as other significant anomalies. The L1 ephemeris fits the observations much more closely than E5 but discrepancies for the resonant satellites are still apparent and the measured positions of Io are drifting away from the predictions. The JUP230 ephemeris fits the observations more accurately than L1 although there is still a measurable discordance between the predictions and observations for Europa at the resonance period.