Measurements of cross sections and couplings of the Higgs boson using the ATLAS detector at CERN’s LHC are presented. Data from proton proton collisions at
s
=
7
, 8 and 13 TeV are discussed. A range ...of production and decay couplings can be tested with a precision that depends on the generality of the assumptions made. Data at 7 and 8 TeV are also combined with CMS results to enhance the precision. The results are all consistent with predictions of the Standard Model.
Highlights • We have developed silicon sensors for online beam monitoring of MRT beams. • The sensors have been tested in sessions at the ID17 and ID21 beamline. • The sensors behave as per design ...specifications. • The sensors are radiation hard, showing no signs of damage up to doses of 250 MRad. • The electrode configuration correctly isolates the regions of interest, preventing cross-talk between the different strips.
Abstract Stereotactic Synchrotron Radiotherapy (SSRT) and Microbeam Radiation Therapy (MRT) are both novel approaches to treat brain tumor and potentially other tumors using synchrotron radiation. ...Although the techniques differ by their principles, SSRT and MRT share certain common aspects with the possibility of combining their advantages in the future. For MRT, the technique uses highly collimated, quasi-parallel arrays of X-ray microbeams between 50 and 600 keV. Important features of highly brilliant Synchrotron sources are a very small beam divergence and an extremely high dose rate. The minimal beam divergence allows the insertion of so called Multi Slit Collimators (MSC) to produce spatially fractionated beams of typically ∼25–75 micron-wide microplanar beams separated by wider (100–400 microns center-to-center(ctc)) spaces with a very sharp penumbra. Peak entrance doses of several hundreds of Gy are extremely well tolerated by normal tissues and at the same time provide a higher therapeutic index for various tumor models in rodents. The hypothesis of a selective radio-vulnerability of the tumor vasculature versus normal blood vessels by MRT was recently more solidified. SSRT (Synchrotron Stereotactic Radiotherapy) is based on a local drug uptake of high-Z elements in tumors followed by stereotactic irradiation with 80 keV photons to enhance the dose deposition only within the tumor. With SSRT already in its clinical trial stage at the ESRF, most medical physics problems are already solved and the implemented solutions are briefly described, while the medical physics aspects in MRT will be discussed in more detail in this paper.
We describe a measurement of the time-integrated luminosity of the data collected by the BABAR experiment at the PEP-II asymmetric-energy e+e- collider at the Upsilon(4S), Upsilon(3S), and ...Upsilon(2S) resonances and in a continuum region below each resonance. We measure the time-integrated luminosity by counting e+e- --> e+e- and (for the Upsilon(4S) only) e+e- --> mu+mu- candidate events, allowing additional photons in the final state. We use data-corrected simulation to determine the cross sections and reconstruction efficiencies for these processes, as well as the major backgrounds. Due to the large cross sections of e+e- --> e+e- and +e- --> mu+mu-, the statistical uncertainties of the measurement are substantially smaller than the systematic uncertainties. The dominant systematic uncertainties are due to observed differences between data and simulation, as well as uncertainties on the cross sections. For data collected on the Upsilon(3S) and Upsilon(2S) resonances, an additional uncertainty arises due to Upsilon --> e+e- background. For data collected off the Upsilon resonances, we estimate an additional uncertainty due to the time-dependent efficiency variations, which can affect the short off-resonance runs.
Silicon microstrip detectors for the ATLAS SCT Robinson, D.; Allport, P.; Andricek, L. ...
Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment,
06/2002, Letnik:
485, Številka:
1
Journal Article
Recenzirano
The ATLAS Semiconductor Tracker at the Large Hadron Collider (LHC) will incorporate ∼20,000 individual silicon microstrip sensors representing
∼60
m
2
of silicon. Production and delivery of the ...sensors is already underway and scheduled for completion by late 2002. The sensors have been optimised for operation in the harsh radiation environment of the LHC, and subjected to an extensive qualification program in which their pre- and post-irradiation characteristics have been evaluated. The sensor design features are reviewed, together with their electrical characteristics and the Quality Control procedures adopted by ATLAS during production.