The desired control of size, structure, and optical properties of fluorescent carbon dots (CDs) is critical for understanding the fluorescence mechanism and exploring their potential application. ...Herein, a top‐down strategy to chemically tailor the inexpensive coal to fluorescent CDs by a combined method of carbonization and acidic oxidation etching is reported. The size and optical properties of the as‐made CDs are tuned by controlling the structures of graphitic crystallites in the starting precursor. The coal‐derived CDs exhibit two different distinctive emission modes, where the intensity of the short‐wavelength emission is significantly enhanced by partial reduction treatment. The evolution of the electronic structure and the surface states analysis show that two different types of fluorescence centers, nano‐sized sp2 carbon domains and surface defects, are responsible for the observed emission characteristics. The reduced CDs are demonstrated as an effective fluorescent sensing material for label‐free and selective detection of Cu(II) ions with a detection limit as low as 2.0 nm, showing a great promise for real‐world sensor applications.
Coal‐based CDs for Cu2+ detection: An effective “top‐down” strategy is developed for synthesis of size‐controlled fluorescent carbon dots (CDs) from coal. The reduced CDs (r‐CDs) are used as an effective fluorescent sensor for label‐free fast and selective detection of Cu(II) ions with a detection limit as low as 2.0 nm.
Perioperative use of dexmedetomidine is associated with reduction in postoperative analgesic requirements. This study examined whether dexmedetomidine added to i.v. patient-controlled analgesia (PCA) ...morphine could improve analgesia while reducing opioid-related side-effects.
In this double-blinded, randomized, controlled study, 100 women undergoing abdominal total hysterectomy were allocated to receive either morphine 1 mg ml−1 alone (Group M) or morphine 1 mg ml−1 plus dexmedetomidine 5 μg ml−1 (Group D) for postoperative i.v. PCA, which was programmed to deliver 1 ml per demand with a 5 min lockout interval and no background infusion. Cumulative PCA requirements, pain intensities, cardiovascular and respiratory variables, and PCA-related adverse events were recorded for 24 h after operation.
Compared with Group M, patients in Group D required 29% less morphine during the 0–24 h postoperative period and reported significantly lower pain levels from the second postoperative hour onwards and throughout the study. Whereas levels of sedation were similar between the groups at each observational time point, decreases in heart rate and mean blood pressure from presurgery baseline at 1, 2, and 4 h after operation were significantly greater in Group D (by a range of 5–7 beats min−1 and 10–13%, respectively). The 4–24 h incidence of nausea was significantly lower in Group D (34% vs 56.3%, P<0.05). There was no bradycardia, hypotension, oversedation, or respiratory depression.
The addition of dexmedetomidine to i.v. PCA morphine resulted in superior analgesia, significant morphine sparing, less morphine-induced nausea, and was devoid of additional sedation and untoward haemodynamic changes.
Fullerenes as a unique class of carbon allotropes have been studied extensively for their distinctive material properties and potential technological applications, including those in biology and ...medicine. Since a major focus in the latter has been on drug development and formulation, in this paper we highlight some representative studies related to such a focus, including the use of fullerenes for drug-like functions and for their improving the formulation of established drugs. Also discussed are some other potential medically relevant applications of fullerenes, such as their serving as potent agents in photodynamic therapy and magnetic imaging.
Icotinib has been previously shown to be non-inferior to gefitinib in non-selected advanced non-small-cell lung cancer patients when given as second- or further-line treatment. In this open-label, ...randomized, phase 3 CONVINCE trial, we assessed the efficacy and safety of first-line icotinib versus cisplatin/pemetrexed plus pemetrexed maintenance in lung adenocarcinoma patients with epidermal growth factor receptor (EGFR) mutation.
Eligible participants were adults with stage IIIB/IV lung adenocarcinoma and exon 19/21 EGFR mutations. Participants were randomly allocated (1 : 1) to receive oral icotinib or 3-week cycle of cisplatin plus pemetrexed for up to four cycles; non-progressive patients after four cycles were maintained with pemetrexed until disease progression or intolerable toxicity. The primary end point was progression-free survival (PFS) assessed by independent response evaluation committee. Other end points included overall survival (OS) and safety.
Between January 2013 and August 2014, 296 patients were randomized, and 285 patients were treated (148 to icotinib, 137 to chemotherapy). Independent response evaluation committee-assessed PFS was significantly longer in the icotinib group (11.2 versus 7.9 months; hazard ratio, 0.61, 95% confidence interval 0.43-0.87; P = 0.006). No significant difference for OS was observed between treatments in the overall population or in EGFR-mutated subgroups (exon 19 Del/21 L858R). The most common grade 3 or 4 adverse events (AEs) in the icotinib group were rash (14.8%) and diarrhea (7.4%), compared with nausea (45.9%), vomiting (29.2%), and neutropenia (10.9%) in the chemotherapy group. AEs (79.1% versus 94.2%; P < 0.001) and treatment-related AEs (54.1% versus 90.5%; P < 0.001) were significantly fewer in the icotinib group than in the chemotherapy group.
First-line icotinib significantly improves PFS of advanced lung adenocarcinoma patients with EGFR mutation with a tolerable and manageable safety profile. Icotinib should be considered as a first-line treatment for this patient population.
Two-mode interferometers lay the foundations for quantum metrology. Instead of exploring quantum entanglement in the two-mode interferometers, a single bosonic mode also promises a measurement ...precision beyond the shot-noise limit (SNL) by taking advantage of the infinite-dimensional Hilbert space of Fock states. Here, we demonstrate a single-mode phase estimation that approaches the Heisenberg limit (HL) unconditionally. Due to the strong dispersive nonlinearity and long coherence time of a microwave cavity, quantum states of the form Formula: see text can be generated, manipulated and detected with high fidelities, leading to an experimental phase estimation precision scaling as ∼N
. A 9.1 dB enhancement of the precision over the SNL at N = 12 is achieved, which is only 1.7 dB away from the HL. Our experimental architecture is hardware efficient and can be combined with quantum error correction techniques to fight against decoherence, and thus promises quantum-enhanced sensing in practical applications.