Background Only limited data from large randomized clinical trials have been published on the long-term performance of second-generation drug-eluting stents in bifurcation lesions. Methods We ...investigated in patients in the randomized TWENTE trial the long-term safety and efficacy of treating bifurcation lesions with 2 widely applied second-generation drug-eluting stents, the zotarolimus-eluting Resolute stent (Medtronic Inc, Santa Rosa, CA) and the everolimus-eluting Xience V stent (Abbott Vascular, Santa Clara, CA). Three-year follow-up was available in 99.3%. Patients were categorized into treatment for ≥1 bifurcation lesion versus treatment for nonbifurcation lesions only. Results Among the 1,391 patients of the TWENTE trial, 362 (26%) were treated for bifurcation lesions. At 3-year follow-up, target-vessel failure did not differ between patients treated for bifurcation versus nonbifurcation lesions (13.1% vs 12.6%; P = .84), whereas the periprocedural myocardial infarction rate was higher in patients with bifurcation lesions (6.9% vs 3.1%; P < .01). Of the 362 patients with bifurcation lesion treatment, 179 (49.4%) were treated with Resolute and 183 (50.6%) with Xience V. There was no significant difference in target-vessel failure between the Resolute and Xience V groups with bifurcation treatment (13.6% vs 12.6%; P = .78), and their incidence of definite-or-probable stent thrombosis was low and similar (1.1% vs 0.5%, respectively; P = .62). Conclusion Despite a significant difference in periprocedural myocardial infarction, 3-year clinical outcome after implantation of second-generation stents was favorable and similar for patients with and without bifurcation lesions. In addition, we observed no difference in long-term clinical outcome after bifurcation lesion treatment with Resolute and Xience V stents.
Aim To evaluate the safety and efficacy of 2 novel drug-eluting stents (DES) with biodegradable polymer-based coatings versus a durable coating DES. Methods and Results BIO-RESORT is an ...investigator-initiated, prospective, patient-blinded, randomized multicenter trial in 3540 Dutch all-comers with various clinical syndromes, requiring percutaneous coronary interventions (PCI) with DES implantation. Randomization (stratified for diabetes mellitus) is being performed in a 1:1:1 ratio between ORSIRO sirolimus-eluting stent with circumferential biodegradable coating, SYNERGY everolimus-eluting stent with abluminal biodegradable coating, and RESOLUTE INTEGRITY zotarolimus-eluting stent with durable coating. The primary endpoint is the incidence of the composite endpoint target vessel failure at 1 year, consisting of cardiac death, target vessel-related myocardial infarction, or clinically driven target vessel revascularization. Power calculation assumes a target vessel failure rate of 8.5% with a 3.5% non‐inferiority margin, giving the study a power of 85% (α level .025 adjusted for multiple testing). The impact of diabetes mellitus on post-PCI outcome will be evaluated. The first patient was enrolled on December 21, 2012. Conclusions BIO-RESORT is a large, prospective, randomized, multicenter trial with three arms, comparing two DES with biodegradable coatings versus a reference DES with a durable coating in 3540 all-comers. The trial will provide novel insights into the clinical outcome of modern DES and will address the impact of known and so far undetected diabetes mellitus on post-PCI outcome.
Optimal ostial seating and adequate back-up of guide catheters are required for challenging percutaneous coronary interventions (PCI). The GuideLiner™ (GL) (Vascular Solutions Inc., Minneapolis, MN, ...USA) is a guide catheter extension system that provides active back-up support by deep coronary intubation. We aimed to assess feasibility and safety of GL-use in routine clinical practice.
We prospectively recorded patient and procedural details, technical success, and in-hospital outcome of 65 consecutive patients undergoing "5-in-6" Fr GL-facilitated PCI of 70 target vessels. The GL was mainly used for PCI of complex coronary lesions: 97% (68/70) had American Heart Association/American College of Cardiology (AHA/ACC) lesion types B2/C; 53% (37/70) were distally located; and 23% (17/70) were heavily calcified. Indications were to increase back-up of the guide and facilitate stent delivery (59%; 41/70), achievement of coaxial alignment of the guide catheter (29%; 20/70), and selective contrast injections (13%; 9/70). Device success rate was 93% (65/70). There were no major complications and two minor complications managed without clinical sequelae: one air embolism and one stent dislodgement.
GL-use resulted in increased back-up and guide catheter alignment for stent delivery in unfavourable tortuous coronary anatomies and complex, heavily calcified, and often distally located lesions, which otherwise may have been considered unsuitable for PCI. Procedural success rate was high and there were no major complications.
In patients without a history of diabetes mellitus, increased levels of glycated hemoglobin (HbA1c) are associated with higher cardiovascular risk. The relation between undetected diabetes and ...clinical outcome after percutaneous coronary intervention is unknown. To investigate whether these patients may have an increased risk of periprocedural myocardial infarction (PMI), the most frequent adverse event after percutaneous coronary intervention, we assessed patients of the TWENTE trial (a randomized, controlled, second-generation drug-eluting stent trial) in whom HbA1c data were available. Patients were classified as known diabetics or patients without a history of diabetes who were subdivided into undetected diabetics (HbA1c ≥6.5%) and nondiabetics (HbA1c <6.5%). Systematic measurement of cardiac biomarkers and electrocardiographic assessment were performed. One-year clinical outcome was also compared. Of 626 patients, 44 (7%) were undetected diabetics, 181 (29%) were known diabetics, and 401 (64%) were nondiabetics. In undetected diabetics the PMI rate was higher than in nondiabetics (13.6% vs 3.7%, p = 0.01) and known diabetics (13.6% vs 6.1%, p = 0.11). Multivariate analysis adjusting for covariates confirmed a significantly higher PMI risk in undetected diabetics compared to nondiabetics (odds ratio 6.13, 95% confidence interval 2.07 to 18.13, p = 0.001) and known diabetics (odds ratio 3.73, 95% confidence interval 1.17 to 11.89, p = 0.03). After 1 year, target vessel MI rate was significantly higher in undetected diabetics (p = 0.02) than in nondiabetics, which was related mainly to differences in PMI. Target vessel failure was numerically larger in unknown diabetics than in nondiabetics, but this difference did not reach statistical significance (13.6% vs 8.0%, p = 0.25). In conclusion, undetected diabetics were shown to have an increased risk of PMI.
Background Drug-eluting stents (DES) are increasingly used for the treatment of coronary artery disease. An optimized DES performance is desirable to successfully treat various challenging coronary ...lesions in a broad population of patients. In response to this demand, third-generation DES with an improved deliverability were developed. Promus Element (Boston Scientific, Natick, MA) and Resolute Integrity (Medtronic Vascular, Santa Rosa, CA) are 2 novel third-generation DES for which limited clinical data are available. Accordingly, we designed the current multicenter study to investigate in an all-comers population whether the clinical outcome is similar after stenting with Promus Element versus Resolute Integrity. Methods DUTCH PEERS is a multicenter, prospective, single-blinded, randomized trial in a Dutch all-comers population. Patients with all clinical syndromes who require percutaneous coronary interventions with DES implantation are eligible. In these patients, the type of DES implanted will be randomized in a 1:1 ratio between Resolute Integrity versus Promus Element. The trial is powered based on a noninferiority hypothesis. For each stent arm, 894 patients will be enrolled, resulting in a total study population of 1,788 patients. The primary end point is the incidence of target vessel failure at 1-year follow-up. Summary DUTCH PEERS is the first randomized multicenter trial with a head-to-head comparison of Promus Element and Resolute Integrity to investigate the safety and efficacy of these third-generation DES.
Objectives The aim of this study was to compare the safety and efficacy of Resolute zotarolimus-eluting stents (ZES) (Medtronic Cardiovascular, Santa Rosa, California) with Xience V ...everolimus-eluting stents (EES) (Abbott Vascular Devices, Santa Clara, California) at 1-year follow-up. Background Only 1 randomized trial previously compared these stents. Methods This investigator-initiated, patient-blinded, randomized noninferiority study had limited exclusion criteria (acute ST-segment elevation myocardial infarctions not eligible). Patients (n = 1,391; 81.4% of eligible population) were randomly assigned to ZES (n = 697) or EES (n = 694). Liberal use of stent post-dilation was encouraged. Cardiac biomarkers were systematically assessed. The primary endpoint was target vessel failure (TVF), a composite of cardiac death, myocardial infarction not clearly attributable to non-target vessels, and clinically indicated target-vessel revascularization. An external independent research organization performed clinical event adjudication (100% follow-up data available). Analysis was by intention-to-treat. Results Acute coronary syndromes were present in 52% and “off-label” feature in 77% of patients. Of the lesions, 70% were type B2/C; the post-dilation rate was very high (82%). In ZES and EES, TVF occurred in 8.2% and 8.1%, respectively (absolute risk-difference 0.1%; 95% confidence interval: −2.8% to 3.0%, pnoninferiority = 0.001). There was no significant between-group difference in TVF components. The definite-or-probable stent thrombosis rates were relatively low and similar for ZES and EES (0.9% and 1.2%, respectively, p = 0.59). Definite stent thrombosis rates were also low (0.58% and 0%, respectively, p = 0.12). In EES, probable stent thrombosis beyond day 8 was observed only in patients not adhering to dual antiplatelet therapy. Conclusions Resolute ZES were noninferior to Xience V EES in treating “real-world” patients with a vast majority of complex lesions and “off-label” indications for drug-eluting stents, which were implanted with liberal use of post-dilation. (The Real-World Endeavor Resolute Versus XIENCE V Drug-Eluting SteNt Study: Head-to-head Comparison of Clinical Outcome After Implantation of Second Generation Drug-eluting Stents in a Real World Scenario; NCT01066650 )
Abstract Objectives This study assessed clinical events and patient-reported chest pain 2 years after treatment of all-comers with Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, ...Santa Rosa, California) and Promus Element everolimus-eluting stents (Boston Scientific, Natick, Massachusetts). Background For both drug-eluting stents (DES), no all-comer outcome data from >12 months of follow-up have been published. Although there is increasing interest in patient-reported chest pain following stenting, data with novel DES are scarce. Methods The DUTCH PEERS multicenter trial (TWENTE II) (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial TWENTE II) randomized 1,811 all-comer patients to treatment with 1 type of DES. Monitoring and event adjudication were performed by independent contract research organizations. Results The 2-year follow-up of 1,810 patients (99.9%) was available. The primary composite endpoint target vessel failure occurred in 8.6% and 7.8% of patients treated with zotarolimus- and everolimus-eluting stents, respectively (p = 0.55). Rates of components of target vessel failure were: cardiac death (2.4% vs. 1.9%, p = 0.42); target vessel–related myocardial infarction (2.4% vs. 1.8%, p = 0.33); clinically-indicated target vessel revascularization (4.6% vs. 4.9%, p = 0.83). At 1- and 2-year follow-up, >80% of patients were free from chest pain (no between-stent difference). In addition, >87% of patients were either free from chest pain or experienced pain only at maximal physical exertion, but not during normal daily activities. Patients with chest pain after 12 months at no more than moderate physical effort had a higher risk of target vessel revascularization during the following year (hazard ratio: 1.89 95% confidence interval: 1.05 to 3.39, p = 0.03). Conclusions During the second year of follow-up, the incidence of adverse clinical endpoints remained similar and low for both DES. The vast majority of patients were free from chest pain.
Objectives The aim of this study was to assess the safety and efficacy of the implantation of Resolute zotarolimus-eluting stents (ZES) (Medtronic Inc., Santa Rosa, California) and Xience V ...everolimus-eluting stents (EES) (Abbott Vascular, Santa Clara, California) following strict discontinuation of dual antiplatelet therapy (DAPT) after 12 months. Background Only limited long-term follow-up data are available from head-to-head comparisons of second-generation drug-eluting stents. Methods The randomized TWENTE (The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente) trial is an investigator-initiated study performed in a population with many complex patients and lesions and only limited exclusion criteria. Patients were randomly assigned 1:1 to ZES (n = 697) or EES (n = 694). Results Two-year follow-up information was available on all patients. The rate of continuation of DAPT beyond 12 months was very low (5.4%). The primary endpoint of target vessel failure, a composite of cardiac death, target vessel–related myocardial infarction, and target vessel revascularization, did not differ between ZES and EES (10.8% vs. 11.6, p = 0.65), despite fewer target lesion revascularizations in patients with EES (2.6% vs. 4.9%, p = 0.03). The patient-oriented composite endpoint was similar (16.4% vs. 17.1%, p = 0.75). Two-year rates of definite or probable stent thrombosis were 1.2% and 1.4%, respectively (p = 0.63). Very late definite or probable stent thrombosis occurred only in 2 patients in each study arm (0.3% vs. 0.3%, p = 1.00). Conclusions After 2 years of follow-up and stringent discontinuation of DAPT beyond 12 months, Resolute ZES and Xience V EES showed similar results in terms of safety and efficacy for treating patients with a majority of complex lesions and off-label indications for drug-eluting stents. (The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente TWENTE; NCT01066650 )
The aim of this study was to compare the safety and efficacy of Resolute zotarolimus-eluting stents (ZES) (Medtronic Cardiovascular, Santa Rosa, California) with Xience V everolimus-eluting stents ...(EES) (Abbott Vascular Devices, Santa Clara, California) at 1-year follow-up.
Only 1 randomized trial previously compared these stents.
This investigator-initiated, patient-blinded, randomized noninferiority study had limited exclusion criteria (acute ST-segment elevation myocardial infarctions not eligible). Patients (n = 1,391; 81.4% of eligible population) were randomly assigned to ZES (n = 697) or EES (n = 694). Liberal use of stent post-dilation was encouraged. Cardiac biomarkers were systematically assessed. The primary endpoint was target vessel failure (TVF), a composite of cardiac death, myocardial infarction not clearly attributable to non-target vessels, and clinically indicated target-vessel revascularization. An external independent research organization performed clinical event adjudication (100% follow-up data available). Analysis was by intention-to-treat.
Acute coronary syndromes were present in 52% and "off-label" feature in 77% of patients. Of the lesions, 70% were type B2/C; the post-dilation rate was very high (82%). In ZES and EES, TVF occurred in 8.2% and 8.1%, respectively (absolute risk-difference 0.1%; 95% confidence interval: -2.8% to 3.0%, p(noninferiority) = 0.001). There was no significant between-group difference in TVF components. The definite-or-probable stent thrombosis rates were relatively low and similar for ZES and EES (0.9% and 1.2%, respectively, p = 0.59). Definite stent thrombosis rates were also low (0.58% and 0%, respectively, p = 0.12). In EES, probable stent thrombosis beyond day 8 was observed only in patients not adhering to dual antiplatelet therapy.
Resolute ZES were noninferior to Xience V EES in treating "real-world" patients with a vast majority of complex lesions and "off-label" indications for drug-eluting stents, which were implanted with liberal use of post-dilation. (The Real-World Endeavor Resolute Versus XIENCE V Drug-Eluting SteNt Study: Head-to-head Comparison of Clinical Outcome After Implantation of Second Generation Drug-eluting Stents in a Real World Scenario; NCT01066650).
Objectives To investigate the safety and efficacy of durable polymer drug eluting stents (DES) and biodegradable polymer biolimus eluting stents (biolimus-ES).Design Network meta-analysis of ...randomised controlled trials.Data sources and study selection Medline, Google Scholar, Embase, and Cochrane Central Register of Controlled Trials (CENTRAL) database search for randomised controlled trials comparing at least two of durable polymer sirolimus eluting stents (sirolimus-ES) and paclitaxel eluting stents (paclitaxel-ES), newer durable polymer everolimus eluting stents (everolimus-ES), Endeavor and Resolute zotarolimus eluting stents (zotarolimus-ES), and biodegradable polymer biolimus-ES.Primary outcomes Safety (death, myocardial infarction, definite or probable stent thrombosis) and efficacy (target lesion and target vessel revascularisation) assessed at up to one year and beyond.Results 60 randomised controlled trials were compared involving 63 242 patients with stable coronary artery disease or acute coronary syndrome treated with a DES. At one year, there were no differences in mortality among devices. Resolute and Endeavor zotarolimus-ES, everolimus-ES, and sirolimus-ES, but not biodegradable polymer biolimus-ES, were associated with significantly reduced odds of myocardial infarction (by 29-34%) compared with paclitaxel-ES. Compared with everolimus-ES, biodegradable polymer biolimus-ES were associated with significantly increased odds of myocardial infarction (by 29%), while Endeavor zotarolimus-ES and paclitaxel-ES were associated with significantly increased odds of stent thrombosis. All investigated DES were similar with regards to efficacy endpoints, except for Endeavor zotarolimus-ES and paclitaxel-ES, which were associated with significantly increased the odds of target lesion and target vessel revascularisations compared with other devices. Direction of results beyond one year did not diverge from the findings for up to one year follow-up. Bayesian probability curves showed a gradient in the magnitude of effect, with everolimus-ES and Resolute zotarolimus-ES offering the highest safety profiles.Conclusions The newer durable polymer everolimus-ES and Resolute zotarolimus-ES and the biodegradable polymer biolimus-ES maintain the efficacy of sirolimus-ES; however, for safety endpoints, differences become apparent, with everolimus-ES and Resolute zotarolimus-ES emerging as the safest stents to date.