Over the last few years, pacing of the conduction system (CSP) has emerged as the new standard pacing modality for bradycardia indications, allowing a more physiological ventricular activation ...compared to conventional right ventricular pacing. CSP has also emerged as an alternative modality to conventional biventricular pacing for the delivery of cardiac resynchronization therapy (CRT) in heart failure patients. However, if the initial clinical data seem to support this new physiological-based approach to CRT, the lack of large randomized studies confirming these preliminary results prevents CSP from being used routinely in clinical practice. Furthermore, concerns are still present regarding the long-term performance of pacing leads when employed for CSP, as well as their extractability. In this review article, we provide the state-of-the-art of CSP as an alternative to biventricular pacing for CRT delivery in heart failure patients. In particular, we describe the physiological concepts supporting this approach and we discuss the future perspectives of CSP in this context according to the implant techniques (His bundle pacing and left bundle branch area pacing) and the clinical data published so far.
This study assessed the feasibility and potential benefit of performing ventricular tachycardia (VT) substrate ablation procedures guided by cardiac magnetic resonance (CMR)-derived pixel signal ...intensity (PSI) maps.
CMR-aided VT ablation using PSI maps from late gadolinium enhancement-CMR (LGE-CMR), together with electroanatomical map (EAM) information, has been shown to improve outcomes of VT substrate ablation.
Eighty-four patients with scar-dependent monomorphic VT who underwent substrate ablation were included in the study. In the last 28 (33%) consecutive patients, the procedure was guided by CMR. Procedural data, as well as acute and follow-up outcomes, were compared between patients who underwent guided CMR and 2 control groups: 1) patients who had PSI maps were available but the EAM was acquired and used to select the ablation targets (CMR aided); and 2) patients with no CMR-derived PSI maps available (no CMR).
Mean procedure duration was lower in CMR-guided substrate ablation compared with CMR-aided and no CMR (107 ± 59 min vs. 203 ± 68 min and 227 ± 52 min; p < 0.001 for both comparisons). CMR-guided ablation required less fluoroscopy time than CMR-aided ablation and no CMR (10 ± 4 min vs. 23 ± 11 min and 20 ± 9 min, respectively; p < 0.001 for both comparisons) and less radiofrequency time (15 ± 8 min vs. 20 ± 15 min and 26 ± 10 min; p = 0.16 and p < 0.001, respectively). After substrate ablation, VT inducibility was lower in CMR-guided ablation compared with CMR-aided ablation and no CMR (18% vs. 32% and 46%; p = 0.35 and p = 0.04, respectively), without significant differences in complications. After 12 months, VT recurrence was lower in those who underwent CMR-guided ablation compared with no CMR (log-rank: 0.019), with no differences with CMR-aided ablation.
CMR-guided VT ablation is feasible and safe, significantly reduces the procedural, fluoroscopy, and radiofrequency times, and is associated with a higher noninducibility rate and lower VT recurrence after substrate ablation.
Display omitted
Background
Left atrial wall thickness (LAWT) has been related to pulmonary vein (PV) reconnections after atrial fibrillation (AF) ablation. The aim was to integrate 3D‐LAWT maps in the navigation ...system and analyze the relationship with local reconnection sites during AF‐redo procedures.
Methods
Consecutive patients referred for AF‐redo ablation were included. Procedure was performed using a single catheter technique. LAWT maps obtained from multidetector computerized tomography (MDCT) were imported into the navigation system. LAWT of the circumferential PV line, the reconnected segment and the reconnected point, were analyzed.
Results
Sixty patients 44 (73%) male, age 61 ± 10 years were included. All reconnected veins were isolated using a single catheter technique with 55 min (IQR 47–67) procedure time and 75 s (IQR 50–120) fluoroscopy time. Mean LAWT of the circumferential PV line was 1.46 ± 0.22 mm. The reconnected segment was thicker than the rest of segments of the circumferential PV line (2.05 + 0.86 vs. 1.47 + 0.76, p < .001 for the LPVs; 1.55 + 0.57 vs. 1.27 + 0.57, p < .001 for the RPVs). Mean reconnection point wall thickness (WT) was at the 82nd percentile of the circumferential line in the LPVs and at the 82nd percentile in the RPVs.
Conclusion
A single catheter technique is feasible and efficient for AF‐redo procedures. Integrating the 3D‐LAWT map into the navigation system allows a direct periprocedural estimation of the WT at any point of the LA. Reconnection points were more frequently present in thicker segments of the PV line. The use of 3D‐LAWT maps can facilitate reconnection point identification during AF‐redo ablation.
Cardiac sarcoidosis is associated with heart failure, conduction abnormalities, and life-threatening arrhythmias including ventricular tachycardia (VT). Radiotherapy has been suggested as a treatment ...for extra-cardiac sarcoidosis in patients refractory to immunomodulatory treatment.
The effectiveness and safety of low-dose whole-heart radiotherapy for therapy refractory cardiac sarcoidosis were evaluated in a pre- and post-intervention case report comparing the 54 months before and after treatment. Immunomodulatory low-dose whole-heart irradiation as sarcoidosis treatment consisted of a 2 × 2 Gy scheme. Additionally, high-dose single-fraction stereotactic arrhythmia radioablation of 1 × 20 Gy was applied to the pro-arrhythmic region to manage the ventricular tachycardia episodes. Cardiac sarcoidosis disease activity was measured by hypermetabolic areas on repeated fluorodeoxyglucose (
FFDG)-PET/computed tomography (CT) scans and by evaluating changes in ventricular tachycardia episodes before and after treatment.
One patient with therapy refractory progressive cardiac sarcoidosis and recurrent ventricular tachycardia was treated. The cardiac sarcoidosis disease activity showed a durable regression of inflammatory disease activity from 3 months onwards. The
FFDG-PET/CT scan at 54 months did not show any signs of active cardiac sarcoidosis, and a state of remission was achieved. The number of sustained VT episodes was reduced by 95%. We observed that the development of moderate aortic valve regurgitation was likely irradiation-related. No other irradiation-related adverse events occurred, and the left ventricular ejection fraction remained stable.
We report here for the first time on the beneficial and lasting effects of combined immunomodulatory low-dose whole-heart radiotherapy and high-dose stereotactic arrhythmia radioablation in a patient with therapy refractory cardiac sarcoidosis and recurrent VT.
Over the last decades, the implementation of new technology in cardiac pacemakers and defibrillators as well as the increasing life expectancy have been associated with a higher incidence of ...transvenous lead complications over time. Variable degrees of venous stenosis at the level of the subclavian vein, the innominate trunk and the superior vena cava are reported in up to 50% of implanted patients. Importantly, the number of implanted leads seems to be the main risk factor for such complications. Extraction of abandoned or dysfunctional leads is a potential solution to overcome venous stenosis in case of device upgrades requiring additional leads, but also, in addition to venous angioplasty and stenting, to reduce symptoms related to the venous stenosis itself, i.e., the superior vena cava syndrome. This review explores the role of transvenous lead extraction procedures as therapeutical option in case of central venous disorders related to transvenous cardiac leads. We also describe the different extraction techniques available and other clinical indications for lead extractions such as lead infections. Finally, we discuss the alternative therapeutic options for cardiac stimulation or defibrillation in case of chronic venous occlusions that preclude the implant of conventional transvenous cardiac devices.
Pacemapping (PM) is a useful maneuver for aiding premature ventricular complex (PVC) ablation. Its standalone clinical value is still to be defined.
The purpose of this study was to analyze the ...efficacy of a predefined PM protocol for low-burden PVC ablation, regardless of their site of origin (SOO) and the presence of structural heart disease.
This was a prospective, nonrandomized, multicenter study. The PM protocol was performed when <1 PVC/min was found. The "target area" was delimited by the 3 best matching points >94% correlation, and 3 radiofreqency (RF) applications were delivered.
Of 185 patients, 105 (57%) underwent activation mapping, 60 (32%) were PM-guided, and 20 (11%) were canceled due to absence of PVCs. Baseline QRS, PVC burden, and outflow tract origin were independent predictors of PM-guided ablation. A higher proportion of right ventricular outflow tract SOO in the PM group (52% vs 40%; P = .03) was observed. Mean target area was 0.6 ± 0.9 cm
. Mean 10-ms isochronal area in local activation time (LAT)-guided procedures was higher (1.7 ± 2.3 cm
; P <.001). Mean number of PM matching points acquired was 39 ± 21 (range 6-98). Mean mapping and RF times were similar in both groups. However, significantly shorter procedural (53 ± 24 vs 61 ± 26 minutes; P = .04) as well as RF times (111 ± 51 vs 149 ± 149 seconds; P = .05) were needed in the PM group using the proposed protocol. Global clinical success reached 87% for the PM group and 90% (P = .58) the for LAT mapping group.
When LAT mapping is precluded, application of a PM-guided ablation protocol directed to >94% matching correlation target area is a more efficient alternative with comparable clinical results.
Abstract
Aims
Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) permits characterizing ischaemic scars, detecting heterogeneous tissue channels (HTCs) which constitute the ...arrhythmogenic substrate (AS). Late gadolinium enhancement cardiac magnetic resonance also improves the arrhythmia-free survival when used to guide ventricular tachycardia (VT) substrate ablation. However, its availability may be limited. We sought to evaluate the performance of multidetector cardiac computed tomography (MDCT) imaging in identifying HTCs detected by LGE-CMR in ischaemic patients undergoing VT substrate ablation.
Methods and results
Thirty ischaemic patients undergoing both LGE-CMR and MDCT before VT substrate ablation were included. Using a dedicated post-processing software, two blinded operators, assigned either to LGE-CMR or MDCT analysis, characterized the presence of CMR and computed tomography (CT) channels, respectively. Cardiac magnetic resonance channels were classified as endocardial (layers < 50%), epicardial (layers ≥ 50%), or transmural. Cardiac magnetic resonance- vs. CT-channel concordance was considered when showing the same orientation and American Heart Association (AHA) segment. Mean age was 69 ± 10 years; 90% were male. Mean left ventricular ejection fraction was 35 ± 10%. All patients had CMR channels (n = 76), whereas only 26/30 (86.7%) had CT channels (n = 91). Global sensitivity (Se) and positive predictive values for detecting CMR channels were 61.8% and 51.6%, respectively. MDCT performance improved in patients with epicardial CMR channels (Se 80.5%) and transmural scars (Se 72.2%). In 4/11 (36%) patients with subendocardial myocardial infarction (MI), MDCT was unable to identify the AS.
Conclusions
Compared to LGE-CMR, myocardial wall thickness assessment using MDCT fails to detect the presence of AS in 36% of patients with subendocardial MI, showing modest sensitivity identifying HTCs but a better performance in patients with transmural scars.
Patients with atrial fibrillation (AF) have an increased risk of cognitive decline, potentially resulting from clinically unrecognized vascular brain lesions.
This study sought to assess the ...relationships between cognitive function and vascular brain lesions in patients with AF.
Patients with known AF were enrolled in a multicenter study in Switzerland. Brain magnetic resonance imaging (MRI) and cognitive testing using the Montreal Cognitive Assessment (MoCA) were performed in all participants. Large noncortical or cortical infarcts (LNCCIs), small noncortical infarcts (SNCIs), microbleeds, and white matter lesions were quantified by a central core laboratory. Clinically silent infarcts were defined as infarcts on brain MRI in patients without a clinical history of stroke or transient ischemic attack.
The study included 1,737 patients with a mean age of 73 ± 8 years (28% women, 90% taking oral anticoagulant agents). On MRI, LNCCIs were found in 387 patients (22%), SNCIs in 368 (21%), microbleeds in 372 (22%), and white matter lesions in 1715 (99%). Clinically silent infarcts among the 1,390 patients without a history of stroke or transient ischemic attack were found in 201 patients with LNCCIs (15%) and 245 patients with SNCIs (18%). The MoCA score was 24.7 ± 3.3 in patients with and 25.8 ± 2.9 in those without LNCCIs on brain MRI (p < 0.001). The difference in MoCA score remained similar when only clinically silent LNCCIs were considered (24.9 ± 3.1 vs. 25.8 ± 2.9; p < 0.001). In a multivariable regression model including all vascular brain lesion parameters, LNCCI volume was the strongest predictor of a reduced MoCA (β = −0.26; 95% confidence interval: −0.40 to −0.13; p < 0.001).
Patients with AF have a high burden of LNCCIs and other brain lesions on systematic brain MRI screening, and most of these lesions are clinically silent. LNCCIs were associated with worse cognitive function, even among patients with clinically silent infarcts. Our findings raise the question of MRI screening in patients with AF.