We present a new measurement of $J/\psi$ production in Pb-Pb collisions at 158 GeV/nucleon, from the data sample collected in year 2000 by the NA50 Collaboration, under improved experimental ...conditions with respect to previous years. With the target system placed in vacuum, the setup was better adapted to study, in particular, the most peripheral nuclear collisions with unprecedented accuracy. The analysis of this data sample shows that the ($J/\psi$)/Drell-Yan cross-sections ratio measured in the most peripheral Pb-Pb interactions is in good agreement with the nuclear absorption pattern extrapolated from the studies of proton-nucleus collisions. Furthermore, this new measurement confirms our previous observation that the ($J/\psi$)/Drell-Yan cross-sections ratio departs from the normal nuclear absorption pattern for semi-central Pb-Pb collisions and that this ratio persistently decreases up to the most central collisions.
We report a new measurement of J/ψ, ψ′ and Drell–Yan cross-sections, in the kinematical domain -0.425<ycm<0.575 and -0.5<cosθCS<0.5, performed at the CERN-SPS using 400 GeV/c incident protons on Be, ...Al, Cu, Ag, W and Pb targets. The dependence of the charmonia production cross-sections on the size of the target nucleus allows to quantify the so-called normal nuclear absorption. In the framework of the Glauber model, this new measurement is combined with results previously obtained with the same apparatus, under different experimental conditions, and leads to a precise determination of the J/ψ and ψ′ absorption cross-sections in the surrounding nuclear matter.
A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of ...20–40 μm. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5cm×3cm ALPIDE chips. Already with their thickness of 50µm, they can be successfully bent to radii of about 2cm without any signs of mechanical or electrical damage. During a subsequent characterisation using a 5.4GeV electron beam, it was further confirmed that they preserve their full electrical functionality as well as particle detection performance.
In this article, the bending procedure and the setup used for characterisation are detailed. Furthermore, the analysis of the beam test, including the measurement of the detection efficiency as a function of beam position and local inclination angle, is discussed. The results show that the sensors maintain their excellent performance after bending to radii of 2cm, with detection efficiencies above 99.9% at typical operating conditions, paving the way towards a new class of detectors with unprecedented low material budget and ideal geometrical properties.