Measurement of the half-life of 68Ga García-Toraño, Eduardo; Peyrés Medina, Virginia; Romero, Eduardo ...
Applied radiation and isotopes,
20/May , Letnik:
87
Journal Article
Recenzirano
The half-life of the positron-emitter 68Ga has been measured by following the decay rate with two systems based on ionization chamber and Ge detectors. The decay rate was measured for periods of time ...up to 10 half-lives. The combination of the 6 results obtained with both systems gives a value of T1/2=67.845(18)min, in good agreement with recommended data and with an uncertainty lower than any other previously reported value.
•The half-life of the positron-emitter radionuclide 68Ga was measured.•Two measurement setups (ionization chamber and Ge detector) were used.•Results agree with evaluated data but exhibit lower uncertainty.
The half-life of 18F García-Toraño, Eduardo; Medina, Virginia Peyrés; Ibarra, Miguel Roteta
Applied radiation and isotopes,
2010 Jul-Aug, Letnik:
68, Številka:
7
Journal Article
Recenzirano
The half-life of the positron-emitter
18F has been measured by following the decay rate with three systems: ionization chambers, Ge detectors and coincidence with fast scintillators. The decay rate ...was measured for periods of time up to 9 half-lives. The combination of the results obtained with the three measuring systems gives a value of
T
1/2=1.82871 (18)
h, in good agreement with recommended data and with an estimated uncertainty lower than any other previously reported value.
Measurement of the half-life of super(68)Ga Garcia-Torano, Eduardo; Medina, Virginia Peyres; Romero, Eduardo ...
Applied radiation and isotopes,
05/2014, Letnik:
87
Journal Article
Recenzirano
The half-life of the positron-emitter super(68)Ga has been measured by following the decay rate with two systems based on ionization chamber and Ge detectors. The decay rate was measured for periods ...of time up to 10 half-lives. The combination of the 6 results obtained with both systems gives a value of T sub(1/2)=67.845(18) min, in good agreement with recommended data and with an uncertainty lower than any other previously reported value.
Virginia Peyrés Medina ; bajo la dirección, Eduardo García-Toraño Martínez.
Tesis de la Universidad Complutense de Madrid, Facultad de Ciencias Físicas, Departamento de Física Atómica, Molecular y ...Nuclear, leída el 07-05-2010.
Audience: Specialized
Virginia Peyrés Medina ; bajo la dirección, Eduardo García-Toraño Martínez.
Tesis de la Universidad Complutense de Madrid, Facultad de Ciencias Físicas, Departamento de Física Atómica, Molecular y Nuclear, leída el 07-05-2010.