To determine the extent to which stereoscopic depth perception influences the performance of tasks executed under an operating microscope.
Laboratory of Experimental Ophthalmology, University Medical ...Center Groningen, the Netherlands.
Experimental study.
Medical students were assigned (on the basis of their stereoacuity) to a stereo-sufficient group (depth perception ≤240 seconds of arc arcsec) or stereo-deficient group (≥480 arcsec). They performed a bead-stringing task (a mockup surgical test) under an operating microscope or a task on a cataract surgery simulator. The stereo-sufficient subjects also performed the bead-stringing task under artificial stereo-deficient conditions (binocular and monocular viewing).
The study comprised 77 medical students. The stereo-sufficient subjects performed both tasks faster than the stereo-deficient subjects and artificially stereo-deficient subjects (P ≤ .024). In addition, a within-group analysis established that the stereo-sufficient subjects were faster at the bead-stringing task with stereoscopic viewing than under artificial stereo-deficient conditions with binocular viewing (P ≤ .011).
Having stereovision resulted in better initial performance on certain tasks involving the use of an operating microscope or cataract surgery simulator. However, this study did not show that stereo deficiency necessarily results in an inability to perform such tasks properly. Hence, it was not evident that for admission to an ophthalmology residency program, stereovision should be judged more stringently than other traits.
No author has a financial or proprietary interest in any material or method mentioned.
To determine the vision-related quality of life (VR-QOL) after surgery for macula-off rhegmatogenous retinal detachment (RRD) in relation to visual acuity, contrast acuity, and color vision.
In a ...prospective observational study, we included 55 patients with a macula-off RRD. Best corrected visual acuity (BCVA), color vision (saturated and desaturated color confusion indices (CCI)) and contrast acuity were measured at 12 months postoperatively in both the RRD eye and the fellow control eye, and the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) was filled out.
Operated and fellow control eyes differed significantly in mean LogMAR BCVA (P<0.0001), median Log contrast acuity (P<0.0001), saturated CCI (P = 0.009), and desaturated CCI (P = 0.016). Significant correlations were observed between the NEI VFQ-25 overall composite score and postoperative LogMAR BCVA (R = -0.551, P<0.0001), contrast acuity (R = 0.472, P<0.0001), saturated CCI (R = -0.315, P = 0.023), and desaturated CCI (R = -0.283, P = 0.044).
A lower VR-QOL was highly correlated to a worse postoperative BCVA and contrast acuity and to a lesser extent to color vision disturbances.
Oxidation of high-strength ammonium wastewater can lead to exceptionally high nitrite concentrations; therefore, the effect of high nitrite concentration (>400
mM) was studied using an ...ammonium-oxidizing enrichment culture in a batch reactor. Ammonium was fed to the reactor in portions of 40–150
mM until ammonium oxidation rates decreased and finally stopped. Activity was restored by replacing half of the medium, while biomass was retained by a membrane. The ammonium-oxidizing population obtained was able to oxidize ammonium at nitrite concentrations of up to 500
mM. The maximum specific oxidation activity of the culture in batch test was about 0.040
mmol O
2
g
−1
protein
min
−1 and the
K
s value was 1.5
mM ammonium. In these tests, half of the maximum oxidation activity was still present at a concentration of 600
mM nitrite and approximately 10% residual activity could still be measured at 1200
mM nitrite (pH 7.4), or as a free nitrous acid (FNA) concentration of 6.6
mg
l
−1. Additional experiments showed that the inhibition was caused by nitrite and not by the high sodium chloride concentration of the medium. The added ammonium was mainly converted into nitrite and no nitrite oxidation was observed. In addition, gaseous nitrogen compounds were detected and mass balance calculations revealed a nitrogen loss of approximately 20% using this system. Phylogenetic analyses of 16S rRNA and ammonium monooxygenase (
amoA) genes of the obtained enrichment culture showed that ammonium-oxidizing bacteria of the
Nitrosomonas europaea/
Nitrosococcus mobilis cluster dominated the two clone libraries. Approximately 25% of the 16S rRNA clones showed a similarity of 92% to
Deinococcus-like organisms. Specific fluorescence in situ hybridization (FISH) probes confirmed that these microbes comprised 10–20% of the microbial community in the enrichment. The
Deinococcus-like organisms were located around the
Nitrosomonas clusters, but their role in the community is currently unresolved.
Purpose
To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM).
Methods
We collected a consecutive ...series of 111,898 DM examinations (2003–2011) from one screening unit of the Dutch biennial screening program (age 50–75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the American College of Radiology (ACR) breast density categories.
Results
Of all the examinations, 21.6% were categorized as density category 1 (‘almost entirely fatty’) and 41.5, 28.9, and 8.0% as category 2–4 (‘extremely dense’), respectively. We identified 667 screen-detected and 234 interval cancers. Interval cancer rates were 0.7, 1.9, 2.9, and 4.4‰ and false positive rates were 11.2, 15.1, 18.2, and 23.8‰ for categories 1–4, respectively (both
p
-trend < 0.001). The screening sensitivity, calculated as the proportion of screen-detected among the total of screen-detected and interval tumors, was lower in higher density categories: 85.7, 77.6, 69.5, and 61.0% for categories 1–4, respectively (
p
-trend < 0.001).
Conclusions
Volumetric mammographic density, automatically measured on digital mammograms, impacts screening performance measures along the same patterns as established with ACR breast density categories. Since measuring breast density fully automatically has much higher reproducibility than visual assessment, this automatic method could help with implementing density-based supplemental screening.
In the light of the breast density legislation in the USA, it is important to know a woman's breast cancer risk, but particularly her risk of a tumor that is not detected through mammographic ...screening (interval cancer). Therefore, we examined the associations of automatically measured volumetric breast density with screen-detected and interval cancer risk, separately.
Volumetric breast measures were assessed automatically using Volpara version 1.5.0 (Matakina, New Zealand) for the first available digital mammography (DM) examination of 52,814 women (age 50 - 75 years) participating in the Dutch biennial breast cancer screening program between 2003 and 2011. Breast cancer information was obtained from the screening registration system and through linkage with the Netherlands Cancer Registry. We excluded all screen-detected breast cancers diagnosed as a result of the first digital screening examination. During a median follow-up period of 4.2 (IQR 2.0-6.2) years, 523 women were diagnosed with breast cancer of which 299 were screen-detected and 224 were interval breast cancers. The associations between volumetric breast measures and breast cancer risk were determined using Cox proportional hazards analyses.
Percentage dense volume was found to be positively associated with both interval and screen-detected breast cancers (hazard ratio (HR) 8.37 (95% CI 4.34-16.17) and HR 1.39 (95% CI 0.82-2.36), respectively, for Volpara density grade category (VDG) 4 compared to VDG1 (p for heterogeneity < 0.001)). Dense volume (DV) was also found to be positively associated with both interval and screen-detected breast cancers (HR 4.92 (95% CI 2.98-8.12) and HR 2.30 (95% CI 1.39-3.80), respectively, for VDG-like category (C)4 compared to C1 (p for heterogeneity = 0.041)). The association between percentage dense volume categories and interval breast cancer risk (HR 8.37) was not significantly stronger than the association between absolute dense volume categories and interval breast cancer risk (HR 4.92).
Our results suggest that both absolute dense volume and percentage dense volume are strong markers of breast cancer risk, but that they are even stronger markers for predicting the occurrence of tumors that are not detected during mammography breast cancer screening.
ABCD3 is one of three ATP-binding cassette (ABC) transporters present in the peroxisomal membrane catalyzing ATP-dependent transport of substrates for metabolic pathways localized in peroxisomes. So ...far, the precise function of ABCD3 is not known. Here, we report the identification of the first patient with a defect of ABCD3. The patient presented with hepatosplenomegaly and severe liver disease and showed a striking accumulation of peroxisomal C27-bile acid intermediates in plasma. Investigation of peroxisomal parameters in skin fibroblasts revealed a reduced number of enlarged import-competent peroxisomes. Peroxisomal beta-oxidation of C26:0 was normal, but beta-oxidation of pristanic acid was reduced. Genetic analysis revealed a homozygous deletion at the DNA level of 1758bp, predicted to result in a truncated ABCD3 protein lacking the C-terminal 24 amino acids (p.Y635NfsX1). Liver disease progressed and the patient required liver transplantation at 4 years of age but expired shortly after transplantation. To corroborate our findings in the patient, we studied a previously generated Abcd3 knockout mouse model. Abcd3-/- mice accumulated the branched chain fatty acid phytanic acid after phytol loading. In addition, analysis of bile acids revealed a reduction of C24 bile acids, whereas C27-bile acid intermediates were significantly increased in liver, bile and intestine of Abcd3-/- mice. Thus, both in the patient and in Abcd3-/- mice, there was evidence of a bile acid biosynthesis defect. In conclusion, our studies show that ABCD3 is involved in transport of branched-chain fatty acids and C27 bile acids into the peroxisome and that this is a crucial step in bile acid biosynthesis.
Peroxisomes play a major role in human cellular lipid metabolism, including the β‐oxidation of fatty acids. The most frequent peroxisomal disorder is X‐linked adrenoleukodystrophy (X‐ALD), which is ...caused by mutations in the ABCD1 gene. The protein involved, called ABCD1, or alternatively ALDP, is a member of the ATP‐binding‐cassette (ABC) transporter family and is located in the peroxisomal membrane. The biochemical hallmark of X‐ALD is the accumulation of very long‐chain fatty acids (VLCFAs), due to an im paired peroxisomal β‐oxidation. Although this suggests a role of ALDP in VLCFA import, no experimental evidence is available to substantiate this. In the yeast Saccharomyces cerevisiae, peroxisomes are the exclusive site of fatty acid β‐oxidation. Earlier work has shown that uptake of fatty acids into peroxisomes may occur via two routes, either as free fatty acids thus requiring intraperoxisomal activation into acyl‐CoA esters or as long‐chain acyl‐CoA esters. The latter route involves the two peroxisomal half ABC transporters Pxalp and Pxa2p that form a heterodimeric complex in the perox isomal membrane. Using different strategies, including the analysis of intracellular acyl‐CoA esters by tandem‐MS, we show that the Pxa1p/Pxa2p heterodimer is involved in the transport of a spectrum of acyl‐CoA esters. Interestingly, we found that the mutant phenotype of the pxa1/pxa2Δ mutant can be rescued, at least par tially, by the sole expression of the human ABCD1 cDNA coding for ALDP, the protein that is defective in the human disease X‐linked adrenoleukodystrophy. Our data indicate that ALDP can function as a ho modimer and is involved in the transport of acyl‐CoA esters across the peroxisomal membrane.— van Roer mund, C. W. T., Visser, W. F., IJlst, L., van Cruchten, A., Boek, M., Kulik, W., Waterham, H. R., Wanders, R. J. A. The human peroxisomal ABC half transporter ALDP functions as a homodimer and accepts acyl–CoA esters. FASEB J. 22, 4201–4208 (2008)
A preliminary study toward consistent soil moisture products from the Advanced Microwave Scanning Radiometer 2 (AMSR2) is presented. Its predecessor, the Advanced Microwave Scanning Radiometer for ...Earth Observing System (AMSR-E), has providedEarth scientists with a consistent and continuous global soil moisture dataset. A major challenge remains to achieve synergy between these soil moisture datasets, which is hampered by the lack of an overlapping observation period of the sensors. Here, observations of the multifrequency microwave radiometer on board the Tropical Rainfall Measuring Mission (TRMM) satellite were used to improve consistency between AMSR-E and AMSR2. Several scenarios to achieve synergy between the AMSR-E and AMSR2 soil moisture products were evaluated. The novel soil moisture retrievals from C-band observations, a frequency band that is lacking on board the TRMM satellite, are also presented. A global comparison of soil moisture retrievals against ERA-Interim soil moisture demonstrates the need for an intercalibration procedure. Several different scenarios based on filtering were tested, and the impact on the soil moisture retrievals was evaluated against two independent reference soil moisture datasets (reanalysis and in situ soil moisture) that cover both individual observation periods of the AMSR-E and AMSR2 sensors. Results show a high degree of consistency between both satellite products and two independent reference products for the soil moisture products retrieved from X-band observations. Care should be taken in the interpretation of the presented soil moisture products, and future research is needed to further align the AMSR2 and AMSR-E sensor calibrations.