A
bstract
The ratio
R
= Γ(
K
S
→ πeν
)
/
Γ(
K
S
→ π
+
π
−
) has been measured with a sample of 300 million
K
S
mesons produced in
ϕ → K
L
K
S
decays recorded by the KLOE experiment at the DAΦNE
e
+
e
...−
collider.
K
S
→ πeν
events are selected by a boosted decision tree built with kinematic variables and time-of-flight measurements. Data control samples of
K
L
→ πeν
decays are used to evaluate signal selection efficiencies. With 49647
±
316 signal events we measure
R
= (1
.
0421
±
0
.
0066
stat
±
0
.
0075
syst
)
×
10
−
3
. The combination with our previous measurement gives
R
= (1
.
0338
±
0
.
0054
stat
±
0
.
0064
syst
)
×
10
−
3
. From this value we derive the branching fraction
B
(
K
S
→ πeν
) = (7
.
153
±
0
.
037
stat
±
0
.
044
syst
)
×
10
−
4
and
f
+
(0)
|V
us
|
= 0
.
2170
±
0
.
009.
A
bstract
The quantum interference between the decays of entangled neutral kaons is studied in the process
ϕ
→ K
S
K
L
→
π
+
π
−
π
+
π
−
, which exhibits the characteristic Einstein-Podolsky-Rosen ...correlations that prevent both kaons to decay into
π
+
π
−
at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon pair state, and to search for tiny decoherence and
CPT
violation effects, which may be justified in a quantum gravity framework.
The analysed data sample was collected with the KLOE detector at DAΦNE, the Frascati
ϕ
-factory, and corresponds to an integrated luminosity of about 1.7 fb
−
1
, i.e. to about 1
.
7 × 10
9
ϕ
→ K
S
K
L
decays produced. From the fit of the observed ∆
t
distribution, being ∆
t
the difference of the kaon decay times, the decoherence and
CPT
violation parameters of various phenomenological models are measured with a largely improved accuracy with respect to previous analyses.
The results are consistent with no deviation from quantum mechanics and
CPT
symmetry, while for some parameters the precision reaches the interesting level at which — in the most optimistic scenarios — quantum gravity effects might show up. They provide the most stringent limits up to date on the considered models.
Abstract
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies ...in predictions for the electron–positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10
−4
, with an over threefold improvement on the previous measurement.
Based on a sample of 300 million KS mesons produced in ϕ→KLKS decays recorded by the KLOE experiment at the DAΦNE e+e− collider we have measured the branching fraction for the decay KS→πμν. The KS ...mesons are identified by the interaction of KL mesons in the detector. The KS→πμν decays are selected by a boosted decision tree built with kinematic variables and by a time-of-flight measurement. Signal efficiencies are evaluated with data control samples of KL→πμν decays. A fit to the reconstructed muon mass distribution finds 7223±180 signal events. Normalising to the KS→π+π− decay events the result for the branching fraction is B(KS→πμν)=(4.56±0.11stat±0.17syst)×10−4. It is the first measurement of this decay mode and the result allows an independent determination of |Vus| and a test of the lepton-flavour universality.
A novel method of hit time and hit position reconstruction in scintillator detectors is described. The method is based on comparison of detector signals with results stored in a library of ...synchronized model signals registered for a set of well-defined positions of scintillation points. The hit position is reconstructed as the one corresponding to the signal from the library which is most similar to the measurement signal. The time of the interaction is determined as a relative time between the measured signal and the most similar one in the library. A degree of similarity of measured and model signals is defined as the distance between points representing the measurement- and model-signal in the multi-dimensional measurement space. Novelty of the method lies also in the proposed way of synchronization of model signals enabling direct determination of the difference between time-of-flights (TOF) of annihilation quanta from the annihilation point to the detectors. The introduced method was validated using experimental data obtained by means of the double strip prototype of the J-PET detector and 22Na sodium isotope as a source of annihilation gamma quanta. The detector was built out from plastic scintillator strips with dimensions of 5mm×19mm×300mm, optically connected at both sides to photomultipliers, from which signals were sampled by means of the Serial Data Analyzer. Using the introduced method, the spatial and TOF resolution of about 1.3cm (σ) and 125ps (σ) were established, respectively.
A detection system of the conventional PET tomograph is set-up to record data from annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a ...radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in point-like sources and in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of 40 ps. Recent positron annihilation lifetime spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.
J-PET is a detector optimized for registration of photons from the electron–positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration ...of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of 511 keV photons via Compton scattering. For scattering angles of about 82
∘
(where the best contrast for polarization measurement is theoretically predicted) we find that the single event resolution for the determination of the polarization is about 40
∘
(predominantly due to properties of the Compton effect). However, for samples larger than ten thousand events the J-PET is capable of determining relative average polarization of these photons with the precision of about few degrees. The obtained results open new perspectives for studies of various physics phenomena such as quantum entanglement and tests of discrete symmetries in decays of positronium and extend the energy range of polarization measurements by five orders of magnitude beyond the optical wavelength regime.
Recent tests of a single module of the Jagiellonian Positron Emission Tomography system (J-PET) consisting of 30 cm long plastic scintillator strips have proven its applicability for the detection of ...annihilation quanta (0.511 MeV) with a coincidence resolving time (CRT) of 0.266 ns. The achieved resolution is almost by a factor of two better with respect to the current TOF-PET detectors and it can still be improved since, as it is shown in this article, the intrinsic limit of time resolution for the determination of time of the interaction of 0.511 MeV gamma quanta in plastic scintillators is much lower. As the major point of the article, a method allowing to record timestamps of several photons, at two ends of the scintillator strip, by means of matrix of silicon photomultipliers (SiPM) is introduced. As a result of simulations, conducted with the number of SiPM varying from 4 to 42, it is shown that the improvement of timing resolution saturates with the growing number of photomultipliers, and that the Formula: see text configuration at two ends allowing to read twenty timestamps, constitutes an optimal solution. The conducted simulations accounted for the emission time distribution, photon transport and absorption inside the scintillator, as well as quantum efficiency and transit time spread of photosensors, and were checked based on the experimental results. Application of the Formula: see text matrix of SiPM allows for achieving the coincidence resolving time in positron emission tomography of Formula: see text0.170 ns for 15 cm axial field-of-view (AFOV) and Formula: see text0.365 ns for 100 cm AFOV. The results open perspectives for construction of a cost-effective TOF-PET scanner with significantly better TOF resolution and larger AFOV with respect to the current TOF-PET modalities.