Purpose
To study the influence of gradient echo–based contrasts as input channels to a 3D patch‐based neural network trained for synthetic CT (sCT) generation in canine and human populations.
Methods
...Magnetic resonance images and CT scans of human and canine pelvic regions were acquired and paired using nonrigid registration. Magnitude MR images and Dixon reconstructed water, fat, in‐phase and opposed‐phase images were obtained from a single T1‐weighted multi‐echo gradient‐echo acquisition. From this set, 6 input configurations were defined, each containing 1 to 4 MR images regarded as input channels. For each configuration, a UNet‐derived deep learning model was trained for synthetic CT generation. Reconstructed Hounsfield unit maps were evaluated with peak SNR, mean absolute error, and mean error. Dice similarity coefficient and surface distance maps assessed the geometric fidelity of bones. Repeatability was estimated by replicating the training up to 10 times.
Results
Seventeen canines and 23 human subjects were included in the study. Performance and repeatability of single‐channel models were dependent on the TE‐related water–fat interference with variations of up to 17% in mean absolute error, and variations of up to 28% specifically in bones. Repeatability, Dice similarity coefficient, and mean absolute error were statistically significantly better in multichannel models with mean absolute error ranging from 33 to 40 Hounsfield units in humans and from 35 to 47 Hounsfield units in canines.
Conclusion
Significant differences in performance and robustness of deep learning models for synthetic CT generation were observed depending on the input. In‐phase images outperformed opposed‐phase images, and Dixon reconstructed multichannel inputs outperformed single‐channel inputs.
Magnetic resonance imaging (MRI) is increasingly utilized as a radiation‐free alternative to computed tomography (CT) for the diagnosis and treatment planning of musculoskeletal pathologies. MR ...imaging of hard tissues such as cortical bone remains challenging due to their low proton density and short transverse relaxation times, rendering bone tissues as nonspecific low signal structures on MR images obtained from most sequences. Developments in MR image acquisition and post‐processing have opened the path for enhanced MR‐based bone visualization aiming to provide a CT‐like contrast and, as such, ease clinical interpretation. The purpose of this review is to provide an overview of studies comparing MR and CT imaging for diagnostic and treatment planning purposes in orthopedic care, with a special focus on selective bone visualization, bone segmentation, and three‐dimensional (3D) modeling. This review discusses conventional gradient‐echo derived techniques as well as dedicated short echo time acquisition techniques and post‐processing techniques, including the generation of synthetic CT, in the context of 3D and specific bone visualization. Based on the reviewed literature, it may be concluded that the recent developments in MRI‐based bone visualization are promising. MRI alone provides valuable information on both bone and soft tissues for a broad range of applications including diagnostics, 3D modeling, and treatment planning in multiple anatomical regions, including the skull, spine, shoulder, pelvis, and long bones.
Level of Evidence
3
Technical Efficacy
Stage 3
This study evaluated the accuracy of synthetic computed tomography (sCT), as compared to CT, for the 3D assessment of the hip morphology. Thirty male patients with asymptomatic hips, referred for ...magnetic resonance (MR) imaging and CT, were included in this retrospective study. sCT images were generated from three‐dimensional radiofrequency‐spoiled T1‐weighted multi‐echo gradient‐echo MR images using a commercially available deep learning‐enabled software and were compared with CT images through mean error and surface distance computation and by means of eight clinical morphometric parameters relevant for hip care. Parameters included center‐edge angle (CEA), sharp angle, acetabular index, extrusion index, femoral head center‐to‐midline distance, acetabular version (AV), and anterior and posterior acetabular sector angles. They were measured by two senior orthopedic surgeons and a radiologist in‐training on CT and sCT images. The reliability and agreement of CT‐ and sCT‐based measurements were assessed using intraclass correlation coefficients (ICCs) for absolute agreement, Bland–Altman plots, and two one‐sided tests for equivalence. The surface distance between CT‐ and sCT‐based bone models were on average submillimeter. CT‐ and sCT‐based measurements showed moderate to excellent interobserver and intraobserver correlation (0.56 < ICC < 0.99). In particular, the inter/intraobserver agreements were good for AV (ICC > 0.75). For CEA, the intraobserver agreement was good (ICC > 0.75) and the interobserver agreement was moderate (ICC > 0.69). Limits of agreements were similar between intraobserver CT and intermodal measurements. All measurements were found statistically equivalent, with average intermodal differences within the intraobserver limits of agreement. In conclusion, sCT and CT were equivalent for the assessment of the hip joint bone morphology.
This study compared magnetic resonance imaging‐based synthetic computed tomography (sCT) to conventional CT for the morphological assessment of the hip joint. The sCT generation technique reconstructed radiodensity contrast accurately, providing bone models within a submillimeter accuracy to CT‐based bone models. CT and sCT images were found statistically equivalent for measuring eight morphometric parameters clinically relevant in hip care. For both modalities, moderate to excellent interobserver and intraobserver reliability were obtained. This provides new possibilities in the radiation‐free diagnosis and surgical planning.
The concept of a novel patient-specific 3D-printed shelf implant should be evaluated in a relevant large animal model with hip dysplasia. Therefore, three dogs with radiographic bilateral hip ...dysplasia and a positive subluxation test underwent unilateral acetabular augmentation with a 3D-printed dog-specific titanium implant. The contralateral side served as control. The implants were designed on CT-based pelvic bone segmentations and extended the dysplastic acetabular rim to increase the weight bearing surface without impairing the range of motion. Outcome was assessed by clinical observation, manual subluxation testing, radiography, CT, and gait analysis from 6 weeks preoperatively until termination at 26 weeks postoperatively. Thereafter, all hip joints underwent histopathological examination. The implantation and recovery from surgery was uneventful. Clinical subluxation tests at the intervention side became negative. Imaging showed medialization of the femoral head at the intervention side and the mean (range) CE-angle increased from 94° (84°-99°) preoperative to 119° (117°-120°) postoperative. Gait analysis parameters returned to pre-operative levels after an average follow-up of 6 weeks. Histology showed a thickened synovial capsule between the implant and the femoral head without any evidence of additional damage to the articular cartilage compared to the control side. The surgical implantation of the 3D shelf was safe and feasible. The patient-specific 3D-printed shelf implants restored the femoral head coverage and stability of dysplastic hips without complications. The presented approach holds promise to treat residual hip dysplasia justifying future veterinary clinical trials to establish clinical effectiveness in a larger cohort to prepare for translation to human clinic.
Background and purpose - The shelf arthroplasty was the regular treatment for residual hip dysplasia before it was substituted by the peri-acetabular osteotomy. Yet, evidence regarding the survival ...of shelf arthroplasty surgery has never been systematically documented. Hence, we investigated the survival time of the shelf procedure until revision to THA in patients with primary hip dysplasia. Factors that influenced survival and complications were also examined, along with the accuracy of correcting radiographic parameters to characterize dysplasia.
Material and methods - The inclusion criteria were studies of human adolescents and adults (> 16 years) with primary or congenital hip dysplasia who were treated with a shelf arthroplasty procedure. Data were extracted concerning patient characteristics, survival time, complications, operative techniques, and accuracy of correcting radiographic parameters.
Results - Our inclusion criteria were applicable to 9 studies. The average postoperative Center-Edge Angle and Acetabular Head Index were mostly within target range, but large variations were common. Kaplan-Meier curves (endpoint: conversion to THA) varied between 37% at 20 years' follow-up and 72% at 35 years' follow-up. Clinical failures were commonly associated with pain and radiographic osteoarthritis. Only minor complications were reported with incidences between 17% and 32%.
Interpretation - The shelf arthroplasty is capable of restoring normal radiographic hip parameters and is not associated with major complications. When carefully selected on minimal osteoarthritic changes, hip dysplasia patients with a closed triradiate cartilage may benefit from the shelf procedure with satisfactory survival rates. The importance of the shelf arthroplasty in relation to peri-acetabular osteotomies needs to be further (re)explored.
A digital twin (DT), originally defined as a virtual representation of a physical asset, system, or process, is a new concept in health care. A DT in health care is not a single technology but a ...domain-adapted multimodal modeling approach incorporating the acquisition, management, analysis, prediction, and interpretation of data, aiming to improve medical decision-making. However, there are many challenges and barriers that must be overcome before a DT can be used in health care. In this viewpoint paper, we build on the current literature, address these challenges, and describe a dynamic DT in health care for optimizing individual patient health care journeys, specifically for women at risk for cardiovascular complications in the preconception and pregnancy periods and across the life course. We describe how we can commit multiple domains to developing this DT. With our cross-domain definition of the DT, we aim to define future goals, trade-offs, and methods that will guide the development of the dynamic DT and implementation strategies in health care.
The Chiari osteotomy was a regular treatment for developmental hip dysplasia before it became mostly reserved as a salvage therapy. However, the long-term survival of the Chiari osteotomy has not ...been systematically investigated. We investigated the survival time of the Chiari osteotomy until conversion to total hip arthroplasty (THA) in patients with primary hip dysplasia, and factors which correlated with survival, complications, and the improvement measured in radiographic parameters.
Studies were included when describing patients (> 16 years) with primary hip dysplasia treated with a Chiari osteotomy procedure with 8 years' follow-up. Data on patient characteristics, indications, complications, radiographic parameters, and survival time (endpoint: conversion to THA) were extracted.
8 studies were included. The average postoperative center-edge angle, acetabular head index, and Sharp angle were generally restored within the target range. 3 studies reported Kaplan-Meier survival rates varying from 96% at 10 years to 72% at 20 years' follow-up. Negative survival factors were high age at intervention and pre-existing advanced preoperative osteoarthritis. Moreover, reported complications ranged between 0% and 28.3 %.
The Chiari osteotomy has high reported survival rates and is capable of restoring radiographic hip parameters to healthy values. When carefully selected by young age, and a low osteoarthritis score, patients benefit from the Chiari osteotomy with satisfactory survival rates. The position of the Chiari osteotomy in relation to the periacetabular osteotomies should be further (re-)explored.
This work describes the fabrication, characterization, and biological evaluation of a thin protein-resistant poly(ethylene glycol) (PEG)-based hydrogel coating for antifouling applications. The ...coating was fabricated by free-radical polymerization on silanized glass and silicon and on polystyrene-covered silicon and gold. The physicochemical properties of the coating were characterized by infrared spectroscopy, ellipsometry, and contact angle measurements. In particular, the chemical stability of the coating in artificial seawater was evaluated over a six-month period. These measurements indicated that the degradation process was slow under the test conditions chosen, with the coating thickness and composition changing only marginally over the period. The settlement behavior of a broad and diverse group of marine and freshwater fouling organisms was evaluated. The tested organisms were barnacle larvae (Balanus amphitrite), algal zoospores (Ulva linza), diatoms (Navicula perminuta), and three bacteria species (Cobetia marina, Marinobacter hydrocarbonoclasticus, and Pseudomonas fluorescens). The biological results showed that the hydrogel coating exhibited excellent antifouling properties with respect to settlement and removal.
Background
Three-dimensional (3D)-printed saw guides are frequently used to optimize osteotomy results and are usually designed based on computed tomography (CT), despite the radiation burden, as ...radiation-less alternatives like magnetic resonance imaging (MRI) have inferior bone visualization capabilities. This study investigated the usability of MR-based synthetic-CT (sCT), a novel radiation-less bone visualization technique for 3D planning and design of patient-specific saw guides.
Methods
Eight human cadaveric lower arms (mean age: 78y) received MRI and CT scans as well as high-resolution micro-CT. From the MRI scans, sCT were generated using a conditional generative adversarial network. Digital 3D bone surface models based on the sCT and general CT were compared to the surface model from the micro-CT that was used as ground truth for image resolution. From both the sCT and CT digital bone models saw guides were designed and 3D-printed in nylon for one proximal and one distal bone position for each radius and ulna. Six blinded observers placed these saw guides as accurately as possible on dissected bones. The position of each guide was assessed by optical 3D-scanning of each bone with positioned saw guide and compared to the preplanning. Eight placement errors were evaluated: three translational errors (along each axis), three rotational errors (around each axis), a total translation (∆T) and a total rotation error (∆R).
Results
Surface models derived from micro-CT were on average smaller than sCT and CT-based models with average differences of 0.27 ± 0.30 mm for sCT and 0.24 ± 0.12 mm for CT. No statistically significant positioning differences on the bones were found between sCT- and CT-based saw guides for any axis specific translational or rotational errors nor between the ∆T (
p
= .284) and ∆R (
p
= .216). On Bland-Altman plots, the ∆T and ∆R limits of agreement (LoA) were within the inter-observer variability LoA.
Conclusions
This research showed a similar error for sCT and CT digital surface models when comparing to ground truth micro-CT models. Additionally, the saw guide study showed equivalent CT- and sCT-based saw guide placement errors. Therefore, MRI-based synthetic CT is a promising radiation-less alternative to CT for the creation of patient-specific osteotomy surgical saw guides.
Self-assembled monolayers (SAMs) of galactoside-terminated alkanethiols have protein-resistance properties which can be tuned via the degree of methylation Langmuir 2005, 21, 2971-2980. Specifically, ...a partially methylated compound was more resistant to nonspecific protein adsorption than the hydroxylated or fully methylated counterparts. We investigate whether this also holds true for resistance to the attachment and adhesion of a range of marine species, in order to clarify to what extent resistance to protein adsorption correlates with the more complex adhesion of fouling organisms. The partially methylated galactoside-terminated SAM was further compared to a mixed monolayer of ω-substituted methyl- and hydroxyl-terminated alkanethiols with wetting properties and surface ratio of hydroxyl to methyl groups matching that of the galactoside. The settlement (initial attachment) and adhesion strength of four model marine fouling organisms were investigated, representing both micro- and macrofoulers; two bacteria (Cobetia marina and Marinobacter hydrocarbonoclasticus), barnacle cypris larvae (Balanus amphitrite), and algal zoospores (Ulva linza). The minimum in protein adsorption onto the partially methylated galactoside surface was partly reproduced in the marine fouling assays, providing some support for a relationship between protein resistance and adhesion of marine fouling organisms. The mixed alkanethiol SAM, which was matched in wettability to the partially methylated galactoside SAM, consistently showed higher settlement (initial attachment) of test organisms than the galactoside, implying that both wettability and surface chemistry are insufficient to explain differences in fouling resistance. We suggest that differences in the structure of interfacial water may explain the variation in adhesion to these SAMs.