Background Calcific tendinopathy is one of the most frequent causes of pain in the shoulder and is characterized by the presence of calcific deposits in the rotator cuff; however, calcific deposits ...have also been described in asymptomatic individuals. Only a few authors have reported epidemiologic data on the prevalence of calcific deposits in the rotator cuff. Methods This study analyzed clinical and radiological data of 1219 adults with and without subacromial pain syndrome (SAPS) to assess the prevalence of calcific deposits in the rotator cuff. Multivariate analysis was used to define risk factors associated with the presence of symptomatic calcific tendinopathy. Results Calcific deposits were found in the rotator cuff of 57 of 734 asymptomatic patients (7.8%). Of 485 patients with SAPS, 42.5% had calcific deposits. Age between 30 and 60 years (odds ratio OR, 8.0; 95% confidence interval CI, 2.5-26.3; P < .001), subacromial pain (OR, 7.1; 95% CI, 5.1-9.9, P < .001), and female gender (OR, 1.5; 95% CI, 1.1-2.0; P = .014) were significantly associated with increased odds of calcific deposits. Conclusion This study demonstrates that women aged between 30 and 60 years with SAPS and a calcific deposit of >1.5 cm in length have the highest chance of suffering from symptomatic calcific tendinopathy of the rotator cuff. The prevalence rates of 7.8% in asymptomatic patients and 42.5% in patients with SAPS provide a current view on the epidemiology of calcific deposits in the rotator cuff.
Background and purpose - After introducing a new local infiltration anesthesia (LIA) protocol with addition of 30 mL ropivacaine 2% and 1 mg epinephrine, we noted an increase in early wound leakage. ...As wound leakage is associated with prosthetic joint infection, our department aims to minimize postoperative wound leakage. This study evaluates the incidence of early wound leakage and postoperative pain after knee arthroplasty (KA) following adjustment of the LIA protocol with addition of 30 cc ropivacaine 2% and 1 mg epinephrine.
Patients and methods - In this retrospective medical dossier study all patients (n = 502) undergoing a primary total or unicondylar knee arthroplasty between January 1, 2018 and July 1, 2019 were included. Patients received an LIA protocol containing 120 mL 2 mg/mL ropivacaine (ROPI- group; n = 256). After October 30, patients received an LIA protocol containing 150 mL 2 mg/mL ropivacaine with 1 mg epinephrine in the first 100 mL (ROPI + group; n = 246). The primary outcome measure was early wound leakage (< 72 hours postoperatively), defined as wound fluid leaking past the barrier of the wound dressing. Secondary outcome measure, 10-point numeric rating scale (NRS) pain (< 72 hours postoperatively) was also assessed. Data was evaluated using logistic regression.
Results - The incidence of wound leakage was higher in the ROPI + group: 24% versus 17% in the ROPI- group (p = 0.06). After adjusting for the differences between surgeons the relative risk of this increase was 1.4 (1.0-2.0). The ROPI + and ROPI- group were similar regarding postoperative pain assessment.
Interpretation - Adjustment of the LIA protocol with 30 mL 2% ropivacaine and 1 mg epinephrine led to an increase in early wound leakage in knee arthroplasty but no difference in pain scores.
Aims
Pelvic floor symptoms (PFS), including lower urinary tract symptoms, defecation problems, sexual dysfunction, and pelvic pain, are common in males and females. Comparing pelvic floor musculature ...(PFM) function between sexes may reveal important differences relevant to clinical care. This study aimed to compare male and female PFM function and to assess the function of both sexes with the number and type of PFS.
Methods
We purposively enrolled males and females aged ≥ 21 years with 0–4 PFS based on questionnaire responses in an observational cohort study. Participants then underwent PFM assessment, and muscle function in the external anal sphincter (EAS) and puborectal muscle (PRM) were compared between sexes. The relationships between muscle function and the number and type of PFS were explored.
Results
Of the invited 400 males and 608 females, 199 and 187 underwent PFM assessment, respectively. Compared with females, males more often showed increased EAS and PRM tone during assessments. Compared with males, females more often showed weaker maximum voluntary contraction (MVC) of the EAS and dysfunctional endurance of both muscles; additionally, those with zero or one PFS, sexual dysfunction, and pelvic pain more often showed a weak MVC of the PRM.
Conclusions
Despite a few similarities between males and, females we found differences in muscle tone, MVC, and endurance between male and female PFM function. These findings provide useful insights into the differences in PFM function between males and females.
Purpose
Improvement of biomechanical properties of cobalt–chromium–molybdenum (CoCrMo) implant surface and reduction of adhesive wear is achieved by titanium–nitride (TiN) coating in vitro. Less ...pain, higher postoperative outcome scores and a lower revision rate after TKA with a TiN-coated CoCrMo TKA compared with uncoated CoCrMo TKA after 10-year follow-up was hypothesized.
Methods
In a double-blinded RCT, 101 patients received a cementless mobile-bearing CoCrMo TKA, either TiN-coated or uncoated. The primary outcome measure was the visual analogue scale (VAS) score for pain and secondary outcome measures were the Knee Society Score (KSS), Oxford Knee Score (OKS), revision rate and adverse events. Patients were assessed at 6 weeks, 6 months, 1 year, 5 years and 10 years, postoperatively.
Results
68 patients (67%) were available for 10-year follow-up. No difference was found in any of the assessed outcome measures with a mean decrease in VAS score (31.6 ± 22.9) and a mean increase in OKS (10.9 ± 8.4), KSS (29.3 ± 31.4), KSSK (26.4 ± 18.2) and KSSF (4.1 ± 22.9). Overall revision rate was 7% (coated 6% vs uncoated 8%) without additional revision procedures between 5 and 10-year follow-up.
Conclusions
The in vitro potential benefits of TiN coating did not result in better clinical outcome when compared to an uncoated cementless TKA. Pain, functional outcome and revision rates were comparable after 10-year follow-up. TiN-coated cementless TKA provides comparable good long-term results, similar to uncoated cementless CoCrMo TKA.
Level of evidence
Level 1, Therapeutic Study
Netherlands Trial Register
NL2887/NTR3033.
Objective During laparoscopic surgery distractions often occur and multitasking between surgery and other tasks, such as technical equipment handling, is a necessary competence. In psychological ...research, reduction of adverse effects of distraction is demonstrated when specifically multitasking is trained. The aim of this study was to examine whether multitasking and more specifically task-switching can be trained in a virtual-reality (VR) laparoscopic skills simulator. Design After randomization, the control group trained separately with an insufflator simulation module and a laparoscopic skills exercise module on a VR simulator. In the intervention group, insufflator module and VR skills exercises were combined to develop a new integrated training in which multitasking was a required competence. At random moments, problems with the insufflator appeared and forced the trainee to multitask. During several repetitions of a different multitask VR skills exercise as posttest, performance parameters (laparoscopy time, insufflator time, and errors) were measured and compared between both the groups as well with a pretest exercise to establish the learning effect. A face-validity questionnaire was filled afterward. Setting University Medical Centre Utrecht, The Netherlands. Participants Medical and PhD students ( n = 42) from University Medical Centre Utrecht, without previous experience in laparoscopic simulation, were randomly assigned to either intervention ( n = 21) or control group ( n = 21). Results All participants performed better in the posttest exercises without distraction of the insufflator compared with the exercises in which multitasking was necessary to solve the insufflator problems. After training, the intervention group was significantly quicker in solving the insufflator problems (mean = 1.60 Log(s) vs 1.70 Log(s), p = 0.02). No significant differences between both the groups were seen in laparoscopy time and errors. Conclusion Multitasking has negative effects on the laparoscopic performance. This study suggests an additional learning effect of training multitasking in VR laparoscopy simulation, because the trainees are able to handle a secondary task (solving insufflator problems) quicker. These results may aid the development of laparoscopy VR training programs in approximating real-life laparoscopic surgery.
Abstract Matrix strains due to external loading are different in bones of different pathologies with different bone mineral density (BMD), and are likely sensed by the osteocytes, the putative bone ...mechanosensors. The mechanosensitivity of osteocytes appears to be strongly influenced by their morphology. In this study, we explored the possibility that osteocyte morphology might play a role in various bone pathologies with different BMD. Confocal laser scanning microscopy and nano-CT were used to quantitatively determine 3D morphology and alignment of osteocytes and osteocyte lacunae in human proximal tibial bone with relatively low (osteopenic), medium (osteoarthritic), and high (osteopetrotic) BMD. Osteopenic osteocytes were relatively large and round (lengths 8.9:15.6:13.4 μm), osteopetrotic osteocytes were small and discoid shaped (lengths 5.5:11.1:10.8 μm), and osteoarthritic osteocytes were large and elongated (lengths 8.4:17.3:12.2 μm). Osteopenic osteocyte lacunae showed 3.5 fold larger volume and 2.2 fold larger surface area than osteoarthritic lacunae, whereas osteopetrotic lacunae were 1.9 fold larger and showed 1.5 fold larger surface area than osteoarthritic lacunae. Osteopetrotic osteocyte lacunae had lower alignment than osteopenic and osteoarthritic lacunae as indicated by their lower degree of anisotropy. The differences in 3D morphology of osteocytes and their lacunae in long bones of different pathologies with different BMD might reflect an adaptation to matrix strain due to different external loading conditions. Moreover, since direct mechanosensing of matrix strain likely occurs by the cell bodies, the differences in osteocyte morphology and their lacunae might indicate differences in osteocyte mechanosensitivity. The exact relationship between osteocyte morphology and bone architecture, however, is complex and deserves further study.
Purpose
The Oxford Knee Score (OKS) is a widely known patient-related outcome measure (PROM) to determine pain and knee functioning before and after total knee arthroplasty (TKA). Self-reported ...function is mainly influenced by change in pain; therefore, it was hypothesized that the OKS correlates more with pain than with performance-based functioning.
Methods
In a prospective cohort of 88 patients, who had a cementless mobile-bearing TKA, included in a randomized clinical trial, the correlation between the overall OKS, and its subscales for pain (PCS) and function (FCS), with performance-based functioning using the DynaPort
®
Knee Score (DKS), visual analogue scale score for pain (VAS) and the Knee Society Score (KSS) was evaluated. All scores were measured preoperatively, 6 months and 1 year after surgery. Overall change in outcome over time was analysed until 5 years after surgery.
Results
All scores improved over time. The DKS was influenced by sex, preoperative BMI and age. The internal consistency of the OKS PCS increased over time, whereas the OKS FCS remained the same. The mean postoperative OKS FCS showed moderate correlation with the DKS (
r
= 0.65,
p
< 0.001), and the mean postoperative OKS and OKS PCS showed high correlation with the VAS (
r
= −0.79 and
r
= −0.82, respectively,
p
< 0.001). The mean postoperative KSS showed high correlations with the OKS (
r
= 0.80,
p
< 0.001), the OKS PCS (
r
= 0.72
p
< 0.001) and OKS FCS (
r
= 0.74,
p
< 0.001).
Conclusion
The postoperative OKS and the OKS PCS showed high correlation with pain, but only the postoperative OKS FCS was well correlated with performance-based functioning. This suggests that the OKS is more related to pain and tells us less on postoperative functioning. This is important when the OKS as PROM is used to evaluate the quality of orthopaedic care of patients with TKA.
Level of evidence
III.
Surfaces of medical implants can be enhanced with the favorable properties of titanium-nitride (TiN). In a review of English medical literature, the effects of TiN-coating on orthopaedic implant ...material in preclinical studies were identified and the influence of these effects on the clinical outcome of TiN-coated orthopaedic implants was explored. The TiN-coating has a positive effect on the biocompatibility and tribological properties of implant surfaces; however, there are several reports of third body wear due to delamination, increased ultrahigh molecular weight polyethylene wear, and cohesive failure of the TiN-coating. This might be due to the coating process. The TiN-coating process should be optimized and standardized for titanium alloy articulating surfaces. The clinical benefit of TiN-coating of CoCrMo knee implant surfaces should be further investigated.