Periprosthetic joint infection (PJI) is a serious complication occurring in 1% to 2% of primary arthroplasties, which is associated with high morbidity and need for complex interdisciplinary ...treatment strategies.The challenge in the management of PJI is the persistence of micro-organisms on the implant surface in the form of biofilm. Understanding this ability, the phases of biofilm formation, antimicrobial susceptibility and the limitations of host local immune response allows an individual choice of the most suitable treatment.By using diagnostic methods for biofilm detection such as sonication, the sensitivity for diagnosing PJI is increasing, especially in chronic infections caused by low-virulence pathogens.The use of biofilm-active antibiotics enables eradication of micro-organisms in the presence of a foreign body. The total duration of antibiotic treatment following revision surgery should not exceed 12 weeks. Cite this article:
2019;4:482-494. DOI: 10.1302/2058-5241.4.180092.
The definition criteria and clinical characteristics of implant-associated infection (IAI) caused by Cutibacterium (formerly Propionibacterium) spp. are poorly known. We analyzed microbiologically ...proven Cutibacterium orthopedic IAI in a prospective cohort.
Patients with periprosthetic joint infections (PJI) and fixation device-associated infections (FDAI) caused by Cutibacterium spp. were prospectively included. IAI was defined by significant growth of Cutibacterium spp. and presence of at least one non-microbiological criterion for infection. The McNemar's chi-squared or binomial test was used to compare the performance of diagnostic tests.
Of 121 patients with Cutibacterium IAI, 62 patients (51%) had PJI and 59 (49%) had FDAI. 109 infections (90%) were caused by C. acnes and 12 (10%) by C. avidum. The median time from implantation until diagnosis of infection was 15.7 months (interquartile range, 5-46.5 months). Clinical local signs were present in 30 patients (28%) and radiological implant loosening in 64 patients (63%). Culture sensitivity of sonication fluid was 84%, of peri-implant tissue 84% and of synovial or peri-implant fluid 56% after 14 days of incubation.
Cutibacterium IAI was diagnosed late in the disease course and presented with subtle signs. Prolonged culture incubation and implant sonication improved the poor performance of conventional microbiological tests. Due to lack of reliable diagnostic tests, Cutibacterium remains difficult to detect making the diagnosis challenging.
We documented the adjunctive bacteriophage therapy to treat a chronic relapsing periprosthetic joint infection of the knee and chronic osteomyelitis of the femur caused by multidrug-resistant
The ...combined antibiotic-phage treatment eradicated the infection, and no side effects to phages were observed.
•37 of 57 Staphylococcus aureus strains isolated from infected implants were permissive to Sb-1 infection.•A titer of 107 PFU/mL Sb-1 phage is not sufficient to eradicate methicillin-resistant ...Staphylococcus aureus (MRSA) biofilm.•Sb-1 phage–antibiotic staggered treatment leads to MRSA biofilm eradication.•The exopolysaccharide component of MRSA biofilm matrix is reduced by Sb-1.•Sb-1 kills persisters either directly (at higher titer) or by a Trojan horse effect.
Most antibiotics have limited or no activity against bacterial biofilms, whereas bacteriophages can eradicate biofilms. We evaluated whether Staphylococcus aureus-specific bacteriophage Sb-1 could eradicate biofilm, both alone and in combination with different classes of antibiotics, degrade the extracellular matrix and target persister cells. Biofilm of methicillin-resistant S. aureus (MRSA) ATCC 43300 was treated with Sb-1 alone or in (simultaneous or staggered) combination with fosfomycin, rifampin, vancomycin, daptomycin or ciprofloxacin. The matrix was visualized by confocal fluorescent microscopy. Persister cells were treated with 104 and 107 plaque-forming units (PFU)/mL Sb-1 for 3 h in phosphate-buffered saline (PBS), followed by colony-forming units (CFU) counting. Alternatively, bacteria were washed and incubated in fresh brain heart infusion (BHI) medium and bacterial growth assessed after a further 24 h. Pretreatment with Sb-1 followed by the administration of subinhibitory concentrations of antibiotic caused a synergistic effect in eradicating MRSA biofilm. Sb-1 determined a dose-dependent reduction of matrix exopolysaccharide. Sb-1 at 107 PFU/mL showed direct killing activity on ≈ 5 × 105 CFU/mL persisters. However, even a lower titer had lytic activity when phage-treated persister cells were inoculated in fresh medium, reverting to a normal-growing phenotype. This study provides valuable data on the enhancing effect of Sb-1 on antibiotic efficacy, exhibiting specific antibiofilm features. Sb-1 can degrade the MRSA polysaccharide matrix and target persister cells and is therefore suitable for treatment of biofilm-associated infections.
Display omitted
Abstract
Objectives
The present study aimed to evaluate the status and trends of robotic orthopedic surgery in a clinical setting using bibliometrics.
Methods
All relevant publications on the ...clinical use of robotic surgery in orthopedics were searched from the Web of Science database. Subsequently, data were analyzed using bibliometrics. Visualizing data of bibliographic coupling, co-citation, and co-occurrence analysis were performed using VOSviewer.
Results
In total, 224 clinical studies met the included standards between 2000 to 2019. Global publications presented an increasing annual trend, with the United States found to have the largest number of publications and robotic companies active in the field (
n
= 99), followed by China (
n
= 38), and the United Kingdom (
n
= 27). The institution with the most contributions was the Beijing Jishuitan Hospital in China (
n
= 15). The most productive scholars were Tian Wei and Mont Michael A, with 14 publications each. The top 30 most cited papers list showed 29 publications to be cited on more than 40 occassions. The journal with the most related and influential publications on robotic orthopedic surgery was the Journal of Arthroplasty. Fourteen types of robots were used, with the majority applied in knee and spinal surgery. MAKO was the most widely used robot in hip and knee surgery and Mazor in spinal surgery. Most studies were small sample populations of low-quality in this field. The top 20 most frequently used keywords were identified from 950 author keywords. Research on orthopedic robots were classified into two clusters by co-occurrence networks: spinal-related robotic surgery and joint-related robotic surgery.
Conclusions
The present bibliometric study summarizes the clinical research of orthopedic robots on study type, sample size, type of surgery, robot information, surgical site, most popular keywords, most cited papers, journals, authors, institutions, and countries. These findings may assist the scholars better understand the current status and research trends to guide future practice and directions.
The microbiological diagnosis of periprosthetic joint infection (PJI) is crucial for successful antimicrobial treatment. Cultures have limited sensitivity, especially in patients receiving ...antibiotics. We evaluated the value of multiplex PCR for detection of microbial DNA in sonication fluid from removed orthopedic prostheses. Cases of PJI in which the prosthesis (or part of it) was removed were prospectively included. The removed implant was sonicated, and the resulting sonication fluid was cultured and subjected to multiplex PCR. Of 37 PJI cases (17 hip prostheses, 14 knee prostheses, 4 shoulder prostheses, 1 elbow prosthesis, and 1 ankle prosthesis), pathogens were identified in periprosthetic tissue in 24 (65%) cases, in sonication fluid in 23 (62%) cases, and by multiplex PCR in 29 (78%) cases. The pathogen was detected in 5 cases in sonication fluid only (Propionibacterium acnes in all cases; none of these patients had previously received antibiotics) and in 11 cases by multiplex PCR only (all of these patients had previously received antibiotics). After exclusion of 8 cases caused by P. acnes or Corynebacterium species, which cannot be detected due to the absence of specific primers in the PCR kit, sonication cultures were positive in 17 cases and multiplex PCR sonication cultures were positive in 29 cases (59% versus 100%, respectively; P < 0.01). Among 19 cases (51%) receiving antibiotics, multiplex PCR was positive in all 19 (100%), whereas sonication cultures grew the organism in 8 (42%) (P < 0.01). Multiplex PCR of sonication fluid is a promising test for diagnosis of PJI, particularly in patients who previously received antibiotics. With modified primer sets, multiplex PCR has the potential for further improvement of the diagnosis of PJI.
Purpose
We investigated the value of preoperative pathogen detection and evaluated its concordance with intraoperative cultures in patients with culture-positive periprosthetic joint infection (PJI).
...Methods
Culture-positive PJI episodes with available preoperative (synovial fluid) and intraoperative cultures (periprosthetic tissue, synovial or sonication fluid) were analyzed. The pathogen detection rate in preoperative and intraoperative cultures was compared using Fisher’s exact test and their concordance was calculated.
Results
Among 167 included PJI episodes, 150 were monomicrobial with coagulase-negative staphylococci (
n
= 55, 37%),
S. aureus
(
n
= 34, 23%), and streptococci (
n
= 21, 14%) being the most common pathogens. Seventeen episodes (10%) were polymicrobial infections. The pathogen(s) grew in preoperative culture in 110 and in intraoperative cultures in 153 episodes (66% vs. 92%,
p
< 0.001). The pathogen detection rate was lower in preoperative compared to intraoperative cultures for low-virulent pathogens (40% vs. 94%,
p
< 0.001), polymicrobial infections (59% vs. 100%,
p
= 0.007), and in delayed and late PJI (63% vs. 94%, and 66% vs. 91%, respectively,
p
< 0.001). Full concordance of preoperative and intraoperative cultures was found in 87 episodes (52%). The pathogen was detected solely preoperatively in 14 episodes (8%) and solely intraoperatively in 57 cases (34%); an additional pathogen was found in 3 episodes (2%) preoperatively and in 6 episodes (4%) intraoperatively.
Conclusion
The concordance of preoperative and intraoperative cultures was poor (52%). The sole or an additional pathogen was found exclusively in intraoperative cultures in 38% of PJI episodes, hence preoperative synovial fluid cultures are considered unreliable for pathogen detection in PJI.
To determine the antimicrobial activity against streptococcal biofilm in species mostly isolated from implant-associated infections and examine the effect of enzyme treatment of biofilm on the ...antimicrobial activity of different antibiotics.
The activities of fosfomycin, rifampicin, benzylpenicillin, daptomycin, gentamicin, levofloxacin, proteinase K and their combinations on planktonic and/or biofilm-embedded standard laboratory strains of Streptococcus agalactiae, Streptococcus pyogenes and Streptococcus oralis were investigated in vitro by standard methods and isothermal microcalorimetry.
MIC values obtained for the tested antimicrobials against planktonic bacteria ranged from 0.016 to 128 mg/L for the three species tested. Higher antibiotic concentrations were usually required to reduce biofilm in comparison with planktonic bacteria, with the exception of gentamicin, for which similar concentrations (4-16 mg/L) exerted an effect on both planktonic and biofilm cells. A synergistic effect against the streptococcal biofilm of the three species was observed when gentamicin was combined with benzylpenicillin or with rifampicin. Moreover, antibiotic concentrations comparable to the MIC observed against planktonic cells induced a strong reduction of viable bacteria in proteinase K pre-treated biofilm.
This study shows that the combination of gentamicin with either benzylpenicillin or rifampicin exerts a synergistic effect against biofilms produced by the tested streptococci strains in vitro. Our results also suggest that coupling a dispersal agent with conventional antibiotics may facilitate their access to the bacteria within the biofilm. In vivo and clinical studies are needed in order to confirm whether such a strategy may be effective in the treatment of implant-associated infections caused by streptococci.
The role of Propionibacterium acnes in acne and in a wide range of inflammatory diseases is well established. However, P. acnes is also responsible for infections involving implants. Prolonged ...aerobic and anaerobic agar cultures for 14 days and broth cultures increase the detection rate. In this paper, we review the pathogenic role of P. acnes in implant-associated infections such as prosthetic joints, cardiac devices, breast implants, intraocular lenses, neurosurgical devices, and spine implants. The management of severe infections caused by P. acnes involves a combination of antimicrobial and surgical treatment (often removal of the device). Intravenous penicillin G and ceftriaxone are the first choice for serious infections, with vancomycin and daptomycin as alternatives, and amoxicillin, rifampicin, clindamycin, tetracycline, and levofloxacin for oral treatment. Sonication of explanted prosthetic material improves the diagnosis of implant-associated infections. Molecular methods may further increase the sensitivity of P. acnes detection. Coating of implants with antimicrobial substances could avoid or limit colonization of the surface and thereby reduce the risk of biofilm formation during severe infections. Our understanding of the role of P. acnes in human diseases will likely continue to increase as new associations and pathogenic mechanisms are discovered.