Purpose
To assess the dose performance in terms of image quality of filtered back projection (FBP) and two generations of iterative reconstruction (IR) algorithms developed by the most common CT ...vendors.
Materials and methods
We used four CT systems equipped with a hybrid/statistical IR (H/SIR) and a full/partial/advanced model-based IR (MBIR) algorithms. Acquisitions were performed on an ACR phantom at five dose levels. Raw data were reconstructed using a standard soft tissue kernel for FBP and one iterative level of the two IR algorithm generations. The noise power spectrum (NPS) and the task-based transfer function (TTF) were computed. A detectability index (d′) was computed to model the detection task of a large mass in the liver (large feature; 120 HU and 25-mm diameter) and a small calcification (small feature; 500 HU and 1.5-mm diameter).
Results
With H/SIR, the highest values of d′ for both features were found for Siemens, then for Canon and the lowest values for Philips and GE. For the large feature, potential dose reductions with MBIR compared with H/SIR were − 35% for GE, − 62% for Philips, and − 13% for Siemens; for the small feature, corresponding reductions were − 45%, − 78%, and − 14%, respectively. With the Canon system, a potential dose reduction of − 32% was observed only for the small feature with MBIR compared with the H/SIR algorithm. For the large feature, the dose increased by 100%.
Conclusion
This multivendor comparison of several versions of IR algorithms allowed to compare the different evolution within each vendor. The use of d′ is highly adapted and robust for an optimization process.
Key Points
• The performance of four CT systems was evaluated by using imQuest software to assess noise characteristic, spatial resolution, and lesion detection.
• Two task functions were defined to model the detection task of a large mass in the liver and a small calcification.
• The advantage of task-based image quality assessment for radiologists is that it does not include only complicated metrics, but also clinically meaningful image quality.
To develop evidence-based recommendations for the use of imaging modalities in primary large vessel vasculitis (LVV) including giant cell arteritis (GCA) and Takayasu arteritis (TAK). European League ...Against Rheumatism (EULAR) standardised operating procedures were followed. A systematic literature review was conducted to retrieve data on the role of imaging modalities including ultrasound, MRI, CT and
F-fluorodeoxyglucose positron emission tomography (PET) in LVV. Based on evidence and expert opinion, the task force consisting of 20 physicians, healthcare professionals and patients from 10 EULAR countries developed recommendations, with consensus obtained through voting. The final level of agreement was voted anonymously. A total of 12 recommendations have been formulated. The task force recommends an early imaging test in patients with suspected LVV, with ultrasound and MRI being the first choices in GCA and TAK, respectively. CT or PET may be used alternatively. In case the diagnosis is still in question after clinical examination and imaging, additional investigations including temporal artery biopsy and/or additional imaging are required. In patients with a suspected flare, imaging might help to better assess disease activity. The frequency and choice of imaging modalities for long-term monitoring of structural damage remains an individual decision; close monitoring for aortic aneurysms should be conducted in patients at risk for this complication. All imaging should be performed by a trained specialist using appropriate operational procedures and settings. These are the first EULAR recommendations providing up-to-date guidance for the role of imaging in the diagnosis and monitoring of patients with (suspected) LVV.
Labeled medical imaging data is scarce and expensive to generate. To achieve generalizable deep learning models large amounts of data are needed. Standard data augmentation is a method to increase ...generalizability and is routinely performed. Generative adversarial networks offer a novel method for data augmentation. We evaluate the use of CycleGAN for data augmentation in CT segmentation tasks. Using a large image database we trained a CycleGAN to transform contrast CT images into non-contrast images. We then used the trained CycleGAN to augment our training using these synthetic non-contrast images. We compared the segmentation performance of a U-Net trained on the original dataset compared to a U-Net trained on the combined dataset of original data and synthetic non-contrast images. We further evaluated the U-Net segmentation performance on two separate datasets: The original contrast CT dataset on which segmentations were created and a second dataset from a different hospital containing only non-contrast CTs. We refer to these 2 separate datasets as the in-distribution and out-of-distribution datasets, respectively. We show that in several CT segmentation tasks performance is improved significantly, especially in out-of-distribution (noncontrast CT) data. For example, when training the model with standard augmentation techniques, performance of segmentation of the kidneys on out-of-distribution non-contrast images was dramatically lower than for in-distribution data (Dice score of 0.09 vs. 0.94 for out-of-distribution vs. in-distribution data, respectively, p < 0.001). When the kidney model was trained with CycleGAN augmentation techniques, the out-of-distribution (non-contrast) performance increased dramatically (from a Dice score of 0.09 to 0.66, p < 0.001). Improvements for the liver and spleen were smaller, from 0.86 to 0.89 and 0.65 to 0.69, respectively. We believe this method will be valuable to medical imaging researchers to reduce manual segmentation effort and cost in CT imaging.
Timely detection and diagnosis are urgently needed to guide epidemiological measures, infection control, antiviral treatment, and vaccine research. In this review, biomarkers/indicators for diagnosis ...of coronavirus disease 2019 (COVID-19) or detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the environment are summarized and discussed. It is concluded that the detection methods targeting antibodies are not suitable for screening of early and asymptomatic cases since most patients had an antibody response at about 10 days after onset of symptoms. However, antibody detection methods can be combined with quantitative real-time reverse transcriptase-polymerase chain reaction (RT-qPCR) to significantly improve the sensitivity and specificity of diagnosis, and boost vaccine research. Fast, sensitive and accurate detection methods targeting antigens need to be developed urgently. Various specimens for diagnosis or detection are compared and analyzed. Among them, deep throat saliva and induced sputum are desired for RT-qPCR test or other early detection technologies. Chest computerized tomography (CT) scan, RT-qPCR, lateral flow immunochromatographic strip (LFICS) for diagnosis of COVID-19 are summarized and compared. Specially, potential electrochemical (EC) biosensor, surface enhanced Raman scattering (SERS)-based biosensor, field-effect transistor (FET)-based biosensor, surface plasmon resonance (SPR)-based biosensor and artificial intelligence (AI) assisted diagnosis of COVID-19 are emphasized. Finally, some commercialized portable detection device, current challenges and future directions are discussed.
•Various biomarkers/indicators for diagnosis of COVID-19 or detection of SARS-CoV-2 are discussed.•Various specimens for diagnosis or detection are compared and analyzed.•CT scan, RT-qPCR, lateral flow immunochromatographic strip for diagnosis of COVID-19 are summarized and compared.•Potential EC biosensor, SERS-based biosensor, and AI assisted diagnosis of COVID-19 are emphasized.
Medical imaging increased rapidly from 2000 to 2006, but trends in recent years have not been analyzed.
To evaluate recent trends in medical imaging.
Retrospective cohort study of patterns of medical ...imaging between 2000 and 2016 among 16 million to 21 million patients enrolled annually in 7 US integrated and mixed-model insurance health care systems and for individuals receiving care in Ontario, Canada.
Calendar year and country (United States vs Canada).
Use of computed tomography (CT), magnetic resonance imaging (MRI), ultrasound, and nuclear medicine imaging. Annual and relative imaging rates by imaging modality, country, and age (children <18 years, adults 18-64 years, and older adults ≥65 years).
Overall, 135 774 532 imaging examinations were included; 5 439 874 (4%) in children, 89 635 312 (66%) in adults, and 40 699 346 (30%) in older adults. Among adults and older adults, imaging rates were significantly higher in 2016 vs 2000 for all imaging modalities other than nuclear medicine. For example, among older adults, CT imaging rates were 428 per 1000 person-years in 2016 vs 204 per 1000 in 2000 in US health care systems and 409 per 1000 vs 161 per 1000 in Ontario; for MRI, 139 per 1000 vs 62 per 1000 in the United States and 89 per 1000 vs 13 per 1000 in Ontario; and for ultrasound, 495 per 1000 vs 324 per 1000 in the United States and 580 per 1000 vs 332 per 1000 in Ontario. Annual growth in imaging rates among US adults and older adults slowed over time for CT (from an 11.6% annual percentage increase among adults and 9.5% among older adults in 2000-2006 to 3.7% among adults in 2013-2016 and 5.2% among older adults in 2014-2016) and for MRI (from 11.4% in 2000-2004 in adults and 11.3% in 2000-2005 in older adults to 1.3% in 2007-2016 in adults and 2.2% in 2005-2016 in older adults). Patterns in Ontario were similar. Among children, annual growth for CT stabilized or declined (United States: from 10.1% in 2000-2005 to 0.8% in 2013-2016; Ontario: from 3.3% in 2000-2006 to -5.3% in 2006-2016), but patterns for MRI were similar to adults. Changes in annual growth in ultrasound were smaller among adults and children in the United States and Ontario compared with CT and MRI. Nuclear medicine imaging declined in adults and children after 2006.
From 2000 to 2016 in 7 US integrated and mixed-model health care systems and in Ontario, rates of CT and MRI use continued to increase among adults, but at a slower pace in more recent years. In children, imaging rates continued to increase except for CT, which stabilized or declined in more recent periods. Whether the observed imaging utilization was appropriate or was associated with improved patient outcomes is unknown.
To describe the use of an imaging selection tool, multiphase computed tomographic (CT) angiography, in patients with acute ischemic stroke (AIS) and to demonstrate its interrater reliability and ...ability to help determine clinical outcome.
The local ethics board approved this study. Data are from the pilot phase of PRoveIT, a prospective observational study analyzing utility of multimodal imaging in the triage of patients with AIS. Patients underwent baseline unenhanced CT, single-phase CT angiography of the head and neck, multiphase CT angiography, and perfusion CT. Multiphase CT angiography generates time-resolved images of pial arteries. Pial arterial filling was scored on a six-point ordinal scale, and interrater reliability was tested. Clinical outcomes included a 50% or greater decrease in National Institutes of Health Stroke Scale (NIHSS) over 24 hours and 90-day modified Rankin Scale (mRS) score of 0-2. The ability to predict clinical outcomes was compared between single-phase CT angiography, multiphase CT angiography, and perfusion CT by using receiver operating curve analysis, Akaike information criterion (AIC), and Bayesian information criterion (BIC).
A total of 147 patients were included. Interrater reliability for multiphase CT angiography is excellent (n = 30, κ = 0.81, P < .001). At receiver operating characteristic curve analysis, the ability to predict clinical outcome is modest (C statistic = 0.56, 95% confidence interval CI: 0.52, 0.63 for ≥50% decrease in NIHSS over 24 hours; C statistic = 0.6, 95% CI: 0.53, 0.68 for 90-day mRS score of 0-2) but better than that of models using single-phase CT angiography and perfusion CT (P < .05 overall). With AIC and BIC, models that use multiphase CT angiography are better than models that use single-phase CT angiography and perfusion CT for a decrease of 50% or more in NIHSS over 24 hours (AIC = 166, BIC = 171.7; values were lowest for multiphase CT angiography) and a 90-day mRS score of 0-2 (AIC = 132.1, BIC = 137.4; values were lowest for multiphase CT angiography).
Multiphase CT angiography is a reliable tool for imaging selection in patients with AIS.
The coronavirus disease 2019 (COVID-19) pandemic is a global health care emergency. Although reverse-transcription polymerase chain reaction testing is the reference standard method to identify ...patients with COVID-19 infection, chest radiography and CT play a vital role in the detection and management of these patients. Prediction models for COVID-19 imaging are rapidly being developed to support medical decision making. However, inadequate availability of a diverse annotated data set has limited the performance and generalizability of existing models. To address this unmet need, the RSNA and Society of Thoracic Radiology collaborated to develop the RSNA International COVID-19 Open Radiology Database (RICORD). This database is the first multi-institutional, multinational, expert-annotated COVID-19 imaging data set. It is made freely available to the machine learning community as a research and educational resource for COVID-19 chest imaging. Pixel-level volumetric segmentation with clinical annotations was performed by thoracic radiology subspecialists for all COVID-19-positive thoracic CT scans. The labeling schema was coordinated with other international consensus panels and COVID-19 data annotation efforts, the European Society of Medical Imaging Informatics, the American College of Radiology, and the American Association of Physicists in Medicine. Study-level COVID-19 classification labels for chest radiographs were annotated by three radiologists, with majority vote adjudication by board-certified radiologists. RICORD consists of 240 thoracic CT scans and 1000 chest radiographs contributed from four international sites. It is anticipated that RICORD will ideally lead to prediction models that can demonstrate sustained performance across populations and health care systems.
Bicuspid aortic stenosis accounts for almost 50% of patients undergoing surgical aortic valve replacement in the younger patients. Expanding the indication of transcatheter aortic valve replacement ...(TAVR) toward lower-risk and younger populations will lead to increased use of TAVR for patients with bicuspid aortic valve (BAV) stenosis despite the exclusion of bicuspid anatomy in all pivotal clinical trials.
This study sought to evaluate the association of BAV morphology and outcomes of TAVR with the new-generation devices.
Patients with BAV confirmed by central core laboratory computed tomography (CT) analysis were included from the international multicenter BAV TAVR registry. BAV morphology including the number of raphe, calcification grade in raphe, and leaflet calcium volume were assessed with CT analysis in a masked fashion. Primary outcomes were all-cause mortality at 1 and 2 years, and secondary outcomes included 30-day major endpoints and procedural complications.
A total of 1,034 CT-confirmed BAV patients with a mean age of 74.7 years and Society of Thoracic Surgeons score of 3.7% underwent TAVR with contemporary devices (n = 740 with Sapien 3; n = 188 with Evolut R/Pro; n = 106 with others). All-cause 30-day, 1-year, and 2-year mortality was 2.0%, 6.7%, and 12.5%, respectively. Multivariable analysis identified calcified raphe and excess leaflet calcification (defined as more than median calcium volume) as independent predictors of 2-year all-cause mortality. Both calcified raphe plus excess leaflet calcification were found in 269 patients (26.0%), and they had significantly higher 2-year all-cause mortality than those with 1 or none of these morphological features (25.7% vs. 9.5% vs. 5.9%; log-rank p < 0.001). Patients with both morphological features had higher rates of aortic root injury (p < 0.001), moderate-to-severe paravalvular regurgitation (p = 0.002), and 30-day mortality (p = 0.016).
Outcomes of TAVR in bicuspid aortic stenosis depend on valve morphology. Calcified raphe and excess leaflet calcification were associated with increased risk of procedural complications and midterm mortality. (Bicuspid Aortic Valve Stenosis Transcatheter Aortic Valve Replacement Registry; NCT03836521)
Display omitted