  • Modification of heat exchanger network design by considering physical properties variation
    Nejad, S. H. A. ...
    The temperature dependency of streamsć physical properties can have a significant effect on heat exchanger networks (HENs) design. An average value can be utilized during each temperature interval in ... order to determine the physical properties of the streams. Another method is the use of the physical propertiesć values, which vary with regard to temperature along each stream. In this paper, the energy targeting for an ammonia plant has already been donebefore using both methods, with and without stream segmentation. Pinch Tmin, and the values of the hot and cold utilities in both cases atemperature,
    Vrsta gradiva - članek, sestavni del
    Leto - 2012
    Jezik - angleški
    COBISS.SI-ID - 16124182