Univerza na Primorskem Univerzitetna knjižnica (UPUK)
-
Effect of rowing ergometer compliance on biomechanical and physiological indicators during simulated 2,000-metre race [Elektronski vir]Šarabon, Nejc ...OBJECTIVES: This study compared biomechanical characteristics and physiological responses during rowing on three devices: (i) stable ergometer (STE), (ii) transversally compliant ergometer (TCE) and ... (iii) frontally compliant ergometer (FCE). METHODS: Eleven young competitive rowers completed a 2000 meter simulated race under each of the ergometer conditions in a randomized order. Stroke rate, average force, power output, velocity and amplitude of the handle and stretcher or seat, heart rate and blood lactate were measured at 500 m intervals. RESULTS: Force and power at the stretcher were significantly lower (p < .03) for TCE, while stroke rate and velocities of the handle and the seat were higher (p < .01). No significant differences were observed between STE and FCE in biomechanical parameters. The lowest rowing performance was observed in FCE (p = .007), and was accompanied with the highest average heart rate (p = .031). DISCUSSION: Our findings indicate that in TCE, rowers modified their technique, but were able to maintain physiological strain and performance. In contrast, FCE had no effect on rowing biomechanics, but decreased rowing performance and increased physiological strain. It seems plausible that transversal, but not frontal compliance, elicited a biomechanical technique that might reduce the discrepancy between a rowing ergometer and on-water rowing.Vir: Journal of Sports Science and Medicine [Elektronski vir] : free electronic journal. - ISSN 1303-2968 (Vol. 18, iss. 2, Jun. 2019, str. 264-270)Vrsta gradiva - e-članek ; neleposlovje za odrasleLeto - 2019Jezik - angleškiCOBISS.SI-ID - 1541154756
Avtor
Šarabon, Nejc |
Kozinc, Žiga |
Babič, Jan |
Marković, Goran
Teme
rowing |
biomechanics |
stability |
power |
velocity |
technique
![loading ... loading ...](themes/default/img/ajax-loading.gif)
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Šarabon, Nejc | 21495 |
Kozinc, Žiga | 51596 |
Babič, Jan | 20216 |
Marković, Goran | ![]() |
Vir: Osebne bibliografije
in: SICRIS
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Naslov za dostavo:
Med podatki člana manjka naslov.
Storitev za pridobivanje naslova trenutno ni dostopna, prosimo, poskusite še enkrat.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in naslov za dostavo ter dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrani naslov za dostavo in dokončali postopek rezervacije.
Obvestilo
Trenutno je storitev za avtomatsko prijavo in rezervacijo nedostopna. Gradivo lahko rezervirate sami na portalu Biblos ali ponovno poskusite tukaj kasneje.
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Gradivo iz matične enote je brezplačno. Če je gradivo na mesto prevzema dostavljeno iz drugih enot, lahko knjižnica to storitev zaračuna.
Mesto prevzema | Status gradiva | Rezervacija |
---|
Rezervacija v teku
Prosimo, počakajte trenutek.
Rezervacija je uspela.
Rezervacija ni uspela.
Rezervacija...
Članska izkaznica:
Mesto prevzema: