Univerza na Primorskem Univerzitetna knjižnica (UPUK)
-
Shear-wave elastography for assessment of trapezius muscle stiffness [Elektronski vir] : reliability and association with low-level muscle activityKozinc, Žiga ; Šarabon, NejcPurpose Shear-wave elastography has been recognized a useful tool for quantifying muscle stiffness, commonly reported as shear modulus, however the reports on reliability are often limited to ... test-retest correlations. In this study, we explored the reliability of shear-wave elastography for assessment of the trapezius muscle stiffness and its relationship with low-level muscle activity. Methods Twenty participants were included in a two-session experiment. Measurements of shear modulus and muscle activity were performed at rest and during low-level activity, induced by shoulder abduction without additional external resistance. Results Good to excellent intra-session repeatability (ICC > 0.80) and moderate inter-rater and inter-session reproducibility (ICC = 0.66%0.74) were observed. Typical errors were acceptable (7.6% of the mean value) only for intra-session measurements in resting conditions, but not acceptable for all conditions with low-level muscle activity (10.2%16.6% of the mean value). Inverse relationships between shear modulus and muscle activity at 40° and 60° of shoulder abduction (r = -0.53 and -0.57) were observed on a group level. We also found higher shear modulus in males compared to females, for the parallel probe position compared to the perpendicular position (in relation to muscle fiber orientation), and for the dominant side of the body compared to the non-dominant side. Conclusions This study showed an inverse relationship between muscle activity in low-level range and shear modulus on a group level, suggesting inherent passive stiffness could account for a larger portion of the variance (compared to muscle activity) in shear modulus when the muscle activity is low. Our results imply that shear-wave elastography can be used in research exploring muscle stiffness, however, caution is needed since only intra-session examination in resting conditions showed acceptable within-participant typical errors. The secondary analyses of the study showed higher shear modulus for males, for the non-dominant side of the body and for the parallel orientation of the ultrasound probe.Vir: PloS one [Elektronski vir]. - ISSN 1932-6203 (Vol. 15, iss. 6, Jun. 2020, str. 1-14)Vrsta gradiva - e-članek ; neleposlovje za odrasleLeto - 2020Jezik - angleškiCOBISS.SI-ID - 19266051
Avtor
Kozinc, Žiga |
Šarabon, Nejc
Teme
elasticity |
stiffness |
trapezius muscles |
ultrasound |
reliability |
elastičnost |
togost |
kapucasta mišica |
ultrazvok |
ponovljivost
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
---|---|---|---|---|---|---|---|---|
JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP |
Baze podatkov, v katerih je revija indeksirana
Ime baze podatkov | Področje | Leto |
---|
Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
---|---|
Kozinc, Žiga | 51596 |
Šarabon, Nejc | 21495 |
Vir: Osebne bibliografije
in: SICRIS
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Naslov za dostavo:
Med podatki člana manjka naslov.
Storitev za pridobivanje naslova trenutno ni dostopna, prosimo, poskusite še enkrat.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrano prevzemno mesto in naslov za dostavo ter dokončali postopek rezervacije.
S klikom na gumb "V redu" boste potrdili zgoraj izbrani naslov za dostavo in dokončali postopek rezervacije.
Obvestilo
Trenutno je storitev za avtomatsko prijavo in rezervacijo nedostopna. Gradivo lahko rezervirate sami na portalu Biblos ali ponovno poskusite tukaj kasneje.
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
Gradivo iz matične enote je brezplačno. Če je gradivo na mesto prevzema dostavljeno iz drugih enot, lahko knjižnica to storitev zaračuna.
Mesto prevzema | Status gradiva | Rezervacija |
---|
Rezervacija v teku
Prosimo, počakajte trenutek.
Rezervacija je uspela.
Rezervacija ni uspela.
Rezervacija...
Članska izkaznica:
Mesto prevzema: