    Sailer, S.; Werner, F.; Hermann, G.; Barcelo, M.; Bauer, C.; Bernhard, S.; Biegger, M.; Canelli, F.; Capasso, M.; Diebold, S.; Eisenkolb, F.; Eschbach, S.; Florin, D.; Föhr, C.; Funk, S.; Gadola, A.; Garrecht, F.; Jung, I.; Kalekin, O.; Kalkuhl, C.; Kihm, T.; Lahmann, R.; Pfeifer, M.; Principe, G.; Pühlhofer, G.; Pürckhauer, S.; Reimer, O.; Santangelo, A.; Scalici, M.; Schanz, T.; Schwab, T.; Steiner, S.; Straumann, U.; Tenzer, C.; Vollhardt, A.; Wolf, D.

    Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 08/2019, Letnik: 936
    Journal Article

    FlashCam is a camera proposed for the medium-sized telescopes of the Cherenkov Telescope Array (CTA). We compare camera trigger rates obtained from measurements with the camera prototype in the laboratory and Monte Carlo simulations, when scanning the parameter space of the fully-digital trigger logic and the intensity of a continuous light source mimicking the night sky background (NSB) during on-site operation. The comparisons of the measured data results to the Monte Carlo simulations are used to verify the FlashCam trigger logic and the expected trigger performance.